Experimental study on seismic performance of abnormal interior joints in steel reinforced concrete hybrid structure for main building in thermal power plants

被引:0
|
作者
机构
[1] Wang, Bo
[2] Bai, Guoliang
[3] Dai, Huijuan
[4] Zhu, Jianing
[5] Li, Hongxing
来源
Bai, G. (guoliangbai@126.com) | 1600年 / Science Press卷 / 34期
关键词
Energy dissipation capacities - Hybrid structure - Interior joints - Quasi-static tests - Seismic Performance - Steel reinforced concrete beams - Steel reinforced concrete columns - Stiffness characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
Split-level, variable beams and columns in main building structure in the thermal power plants bring a large number of abnormal interior joints. The quasi-static test for five typical specimens in 1/5 scale of the prototype model were carried out, to study the hysteretic performance, energy dissipation capacity, ductility, stiffness characteristics and bearing capacity of this kind of abnormal joints. The results show that: the dominant failure mode is plastic hinges failure at column ends for four steel reinforced concrete abnormal interior joints which is not good for seismic resistance, while the failure mode mainly the shear damage in core area for the reinforced concrete abnormal interior joint because the beam-column stiffness ratio is quite large. The height of split-level which is caused by the large beam and small beam has certain influence on the bearing capacity, ductility capacity and stiffness characteristics of steel reinforced concrete abnormal interior joints, but the influence law is not obvious. The dissipation capacity of steel reinforced concrete column-reinforced concrete beam abnormal interior joints is better than the reinforced concrete abnormal interior joint. For the limitation of failure mode, however, the bearing capacity, ductility, stiffness characteristics of steel reinforced concrete column-reinforced concrete beam abnormal interior joints are lower than the reinforced concrete abnormal interior joints'. Compared with the steel reinforced concrete abnormal interior joint with reinforced concrete beams, the initial cracking bearing capacity of steel reinforced concrete abnormal joint with steel reinforced concrete beam is higher, and its stiffness characteristic is better, but its bearing capacity, ductility performance and energy dissipation do not enhance obviously.
引用
收藏
相关论文
共 50 条
  • [41] Experimental study on seismic behavior of interior joints in prestressed concrete assembly frame
    Fu, Xiuyan
    Yu, Yuanyuan
    Han, Jianqiang
    Hong, Xuedi
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 203 - 208
  • [42] Experimental Study on Seismic Performance of Tall Building Structure of Concrete Filled Steel Tube (CFST) with Transfer Story
    Chen, Bowang
    Oyang, Yang
    Tan, Jianguo
    APPLICATIONS OF ENGINEERING MATERIALS, PTS 1-4, 2011, 287-290 : 1882 - +
  • [43] Seismic Performance of Reinforced Concrete Beam to Concrete-filled Steel Tubular Columns Joints
    Qu, Hui
    Han, Lin-Hai
    Tao, Zhong
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 685 - +
  • [44] Experimental study on the seismic behavior of steel reinforced concrete columns
    School of Civil and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China
    不详
    Beijing Keji Daxue Xuebao, 2009, 12 (1516-1524):
  • [45] Seismic performance of reinforced concrete interior beam-column joints with novel reinforcement detail
    Shen, Xinyu
    Li, Bo
    Chen, Yung-Tsang
    Tizani, Walid
    ENGINEERING STRUCTURES, 2021, 227 (227)
  • [46] Study on Seismic Stability of Steel Structure Main Control Building
    Chen, You Hui
    Meng, Xiang Kun
    Yang, Ji Ye
    Liu, Ran
    Ma, Qiang
    Li, Dong Xue
    Lu, Tianqi
    Jiang, Li
    Pan, Qi
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [47] Study on Seismic Behavior of Steel & Concrete Hybrid Structure
    Song, Qiang
    Zhang, Yong
    Xu, Yong
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 1406 - +
  • [48] Experimental study on concrete columns hybrid reinforced by steel and FRP bars under seismic loading
    Sun Z.
    Wu G.
    Wang Y.
    Wu Z.
    Journal of Southeast University (English Edition), 2016, 32 (04) : 439 - 444
  • [49] SEISMIC BEHAVIOR OF STEEL-FIBER REINFORCED-CONCRETE INTERIOR BEAM-COLUMN JOINTS
    FILIATRAULT, A
    PINEAU, S
    HOUDE, J
    ACI STRUCTURAL JOURNAL, 1995, 92 (05) : 543 - 552
  • [50] The effect of roof systems on seismic performance of reinforced concrete frame-bent main building of large-scale thermal power plant
    Chen, Deshen
    Jia, Lizhe
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2015, 24 (03): : 198 - 209