Experimental study on seismic performance of abnormal interior joints in steel reinforced concrete hybrid structure for main building in thermal power plants

被引:0
|
作者
机构
[1] Wang, Bo
[2] Bai, Guoliang
[3] Dai, Huijuan
[4] Zhu, Jianing
[5] Li, Hongxing
来源
Bai, G. (guoliangbai@126.com) | 1600年 / Science Press卷 / 34期
关键词
Energy dissipation capacities - Hybrid structure - Interior joints - Quasi-static tests - Seismic Performance - Steel reinforced concrete beams - Steel reinforced concrete columns - Stiffness characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
Split-level, variable beams and columns in main building structure in the thermal power plants bring a large number of abnormal interior joints. The quasi-static test for five typical specimens in 1/5 scale of the prototype model were carried out, to study the hysteretic performance, energy dissipation capacity, ductility, stiffness characteristics and bearing capacity of this kind of abnormal joints. The results show that: the dominant failure mode is plastic hinges failure at column ends for four steel reinforced concrete abnormal interior joints which is not good for seismic resistance, while the failure mode mainly the shear damage in core area for the reinforced concrete abnormal interior joint because the beam-column stiffness ratio is quite large. The height of split-level which is caused by the large beam and small beam has certain influence on the bearing capacity, ductility capacity and stiffness characteristics of steel reinforced concrete abnormal interior joints, but the influence law is not obvious. The dissipation capacity of steel reinforced concrete column-reinforced concrete beam abnormal interior joints is better than the reinforced concrete abnormal interior joint. For the limitation of failure mode, however, the bearing capacity, ductility, stiffness characteristics of steel reinforced concrete column-reinforced concrete beam abnormal interior joints are lower than the reinforced concrete abnormal interior joints'. Compared with the steel reinforced concrete abnormal interior joint with reinforced concrete beams, the initial cracking bearing capacity of steel reinforced concrete abnormal joint with steel reinforced concrete beam is higher, and its stiffness characteristic is better, but its bearing capacity, ductility performance and energy dissipation do not enhance obviously.
引用
收藏
相关论文
共 50 条
  • [31] Experimental study on seismic performance of a new transfer joint in the steel-concrete vertical hybrid structure
    Gao, Jin-Yang
    Nie, Xin
    Ding, Ran
    Fan, Jian-Sheng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 174
  • [32] Experimental study on seismic performance of prestressed steel reinforced concrete frame structure under vertical reversed loading
    School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China
    不详
    Jianzhu Jiegou Xuebao, 2013, 7 (62-71):
  • [33] Seismic performance of reinforced concrete building frames on sloping ground retrofitted with steel and reinforced concrete jacketing
    Dey, Mithu
    Chakraborty, Subrata
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2024, 9 (11)
  • [34] Seismic performance of vertical hybrid structure consisting of reinforced concrete pipe column and steel truss
    Yue J.
    Qian J.
    Bai G.
    Li H.
    Lei T.
    Jiangsu Daxue Xuebao (Ziran Kexue Ban)/Journal of Jiangsu University (Natural Science Edition), 2010, 31 (05): : 606 - 611
  • [35] Seismic performance of concrete joints strengthened with hybrid-fibre-reinforced polymers
    Sumathi, Marimuthu
    Greeshma, Sivasankarapillai
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2021, 174 (04) : 292 - 317
  • [36] Experimental study on seismic performance of steel reinforced concrete T-shaped columns
    Liu, Zuqiang
    Zhou, Chaofeng
    Xue, Jianyang
    Leon, Roberto T.
    STEEL AND COMPOSITE STRUCTURES, 2020, 36 (03): : 339 - 353
  • [37] Experimental study on seismic performance of steel reinforced high-strength concrete columns
    Li, JH
    Zhao, HT
    Xue, JY
    Wang, LK
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 649 - 655
  • [38] Experimental study on seismic performance of prefabricated core steel tube reinforced concrete columns
    Zhang Y.
    Liu Y.
    Ruan J.
    Zhong P.
    Ren Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (12): : 135 - 144
  • [39] Experimental study on seismic performance of steel reinforced concrete columns after exposure to fire
    Li, Junhua
    Chen, Jianhua
    Sun, Bin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (05): : 124 - 132
  • [40] Experimental Study on Seismic Performance of Steel Reinforced Concrete Column with Recycled Coarse Aggregate
    Ma, Hui
    Xue, Jianyang
    Zhang, Xicheng
    Chen, Zongping
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 2063 - +