Experimental study on seismic performance of abnormal interior joints in steel reinforced concrete hybrid structure for main building in thermal power plants

被引:0
|
作者
机构
[1] Wang, Bo
[2] Bai, Guoliang
[3] Dai, Huijuan
[4] Zhu, Jianing
[5] Li, Hongxing
来源
Bai, G. (guoliangbai@126.com) | 1600年 / Science Press卷 / 34期
关键词
Energy dissipation capacities - Hybrid structure - Interior joints - Quasi-static tests - Seismic Performance - Steel reinforced concrete beams - Steel reinforced concrete columns - Stiffness characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
Split-level, variable beams and columns in main building structure in the thermal power plants bring a large number of abnormal interior joints. The quasi-static test for five typical specimens in 1/5 scale of the prototype model were carried out, to study the hysteretic performance, energy dissipation capacity, ductility, stiffness characteristics and bearing capacity of this kind of abnormal joints. The results show that: the dominant failure mode is plastic hinges failure at column ends for four steel reinforced concrete abnormal interior joints which is not good for seismic resistance, while the failure mode mainly the shear damage in core area for the reinforced concrete abnormal interior joint because the beam-column stiffness ratio is quite large. The height of split-level which is caused by the large beam and small beam has certain influence on the bearing capacity, ductility capacity and stiffness characteristics of steel reinforced concrete abnormal interior joints, but the influence law is not obvious. The dissipation capacity of steel reinforced concrete column-reinforced concrete beam abnormal interior joints is better than the reinforced concrete abnormal interior joint. For the limitation of failure mode, however, the bearing capacity, ductility, stiffness characteristics of steel reinforced concrete column-reinforced concrete beam abnormal interior joints are lower than the reinforced concrete abnormal interior joints'. Compared with the steel reinforced concrete abnormal interior joint with reinforced concrete beams, the initial cracking bearing capacity of steel reinforced concrete abnormal joint with steel reinforced concrete beam is higher, and its stiffness characteristic is better, but its bearing capacity, ductility performance and energy dissipation do not enhance obviously.
引用
收藏
相关论文
共 50 条
  • [21] Seismic Performance Study of Self-Centering Steel Reinforced Concrete Building Joints Under High-Intensity Earthquake
    Zhao, H. R.
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2023, 17 (02) : 191 - 202
  • [23] Seismic behavior of steel-fiber reinforced concrete interior beam-column joints
    Filiatrault, Andre
    Pineau, Sylvain
    Houde, Jules
    ACI Materials Journal, 1995, 92 (05): : 543 - 552
  • [24] Experimental research on seismic behavior of steel reinforced high strength and high performance concrete frame joints
    Zheng, Shansuo
    Zeng, Lei
    Lu, Ying
    Sun, Qinggang
    Wang, Peiqin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2008, 29 (03): : 128 - 136
  • [25] Experimental study on seismic behavior of SRC abnormal interior joints and design advice
    Bai G.
    Zhao J.
    Du N.
    Xie B.
    Gao H.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 (07): : 33 - 45
  • [26] Experimental study on seismic performance of skew steel-concrete composite spatial joints
    Wang W.
    Zhou Y.
    Su S.
    Li Y.
    Zhang Q.
    Zhang S.
    Chen L.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2023, 54 (08): : 3260 - 3272
  • [27] Comparative experimental study on seismic retrofitting methods for full-scale interior reinforced concrete frame joints
    Chen, Yang
    Song, Xiaofang
    Gan, Yingjun
    Ren, Chong
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 86 (03) : 385 - 397
  • [28] Experimental study on seismic behavior of frame interior joints with high-strength lightweight aggregate reinforced concrete
    Wu, Tao
    Liu, Xi
    Wei, Hui
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2018, 51 (06): : 32 - 42
  • [29] Seismic behavior of steel reinforced concrete column-steel truss beam hybrid joints
    Tao, Mu-Xuan
    Fan, Jian-Sheng
    Nie, Jian-Guo
    ENGINEERING STRUCTURES, 2013, 56 : 1557 - 1569
  • [30] Experimental investigation on the seismic performance of steel-polypropylene hybrid fiber reinforced concrete columns
    Huang, Le
    Xu, Lihua
    Chi, Yin
    Xu, Haoran
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 87 : 16 - 27