Structure design and accuracy testing of monochromator in a soft X-ray spectromicroscopic beamline

被引:0
|
作者
机构
[1] Gong, Xuepeng
[2] Lu, Qipeng
[3] Peng, Zhongqi
来源
Lu, Q. (luqipeng@126.com) | 1600年 / Chinese Optical Society卷 / 33期
关键词
Mirrors; -; Synchrotrons; Monochromators; Mechanisms;
D O I
10.3788/AOS201333.0234001
中图分类号
学科分类号
摘要
In order to satisfy the technical requirement of soft X-ray microscopy beamline in Shanghai Synchrotron Radiation Facility (SSRF), whose key assembly monochromator is designed. Wavelength scanning movement principle of monochromator is described. Design scheme of wavelength scanning mechanism is discussed, and factors affecting the angular repeatability of plane mirror and plane grating are analyzed in detail; switching mechanism of plane grating is described, and horizontal deviation, vertical deviation, roll angle precision, yaw angle precision and pitch angle precision are analyzed in detail; six-bar parallel mechanism is used for adjusting the UHV-chamber, and adjusting range and resolution of the bar are analyzed. The entire structure of monochromator is presented, and its precision testing is performed. Results show that the angular repeatability of plane mirror and plane grating are 0.166″ and 0.149″, and roll, yaw and pitch angular repeatability of plane grating switching mechanism are 0.08″, 0.12″ and 0.05″, indicating that structure design and precision of monochromator satisfy the technical demand.
引用
收藏
相关论文
共 50 条
  • [41] An x-ray spectromicroscopic study of the local structure of patterned titanium silicide
    Singh, S
    Solak, H
    Krasnoperov, N
    Cerrina, F
    Cossy, A
    Diaz, J
    Stohr, J
    Samant, M
    APPLIED PHYSICS LETTERS, 1997, 71 (01) : 55 - 57
  • [42] DETERMINATION OF GLITCHES IN SOFT X-RAY MONOCHROMATOR CRYSTALS.
    Van Der Laan, Gerrit
    Thole, Bernard T.
    Nuclear instruments and methods in physics research, 1988, A263 (2-3): : 515 - 521
  • [43] High precision mechanical components for soft X-ray beamline: Engineering goal and testing results
    Kaznacheyev, K. V.
    Karunakaran, Ch.
    Sitnikov, A.
    Loken, D.
    Warwick, T.
    Nagy, M.
    Hitchcock, A. P.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 730 - +
  • [45] A DEDICATED SOFT-X-RAY BEAMLINE FOR X-RAY ABSORPTION-SPECTROSCOPY
    MORRISON, TI
    LIEN, NC
    BUNKER, BA
    SAYERS, DE
    HEALD, SM
    FARERIA, L
    SCROFANI, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1991 - 1991
  • [46] X-ray optics of a dynamical sagittal-focusing monochromator on the GILDA beamline at the ESRF
    Pascarelli, S
    Boscherini, F
    D'Acaptito, F
    Hrdy, J
    Meneghini, C
    Mobilio, S
    JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 : 147 - 155
  • [47] Soft X-ray photochemistry beamline at SPring-8
    Koyano, I
    Okuyama, M
    Ishiguro, E
    Hiraya, A
    Ohashi, H
    Kanashima, T
    Ueda, K
    Suzuki, IH
    Ibuki, T
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 545 - 547
  • [48] New evaluation beamline for soft x-ray optical elements
    Koike, M
    Sano, K
    Yoda, O
    Harada, Y
    Ishino, M
    Moriya, N
    Sasai, H
    Takenaka, H
    Gullikson, E
    Mrowka, S
    Jinno, M
    Ueno, Y
    Underwood, JH
    Namioka, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03): : 1541 - 1544
  • [49] LILIT beamline for soft and deep X-ray lithography at Elettra
    Romanato, F
    Di Fabrizio, E
    Vaccari, L
    Altissimo, M
    Cojoc, D
    Businaro, L
    Cabrini, S
    MICROELECTRONIC ENGINEERING, 2001, 57-8 : 101 - 107
  • [50] Micro-soft x-ray spectroscopy with the LUCIA beamline
    Lagarde, P.
    Flank, A. -M.
    Vantelon, D.
    Janousch, M.
    X-RAY ABSORPTION FINE STRUCTURE-XAFS13, 2007, 882 : 852 - +