Structure design and accuracy testing of monochromator in a soft X-ray spectromicroscopic beamline

被引:0
|
作者
机构
[1] Gong, Xuepeng
[2] Lu, Qipeng
[3] Peng, Zhongqi
来源
Lu, Q. (luqipeng@126.com) | 1600年 / Chinese Optical Society卷 / 33期
关键词
Mirrors; -; Synchrotrons; Monochromators; Mechanisms;
D O I
10.3788/AOS201333.0234001
中图分类号
学科分类号
摘要
In order to satisfy the technical requirement of soft X-ray microscopy beamline in Shanghai Synchrotron Radiation Facility (SSRF), whose key assembly monochromator is designed. Wavelength scanning movement principle of monochromator is described. Design scheme of wavelength scanning mechanism is discussed, and factors affecting the angular repeatability of plane mirror and plane grating are analyzed in detail; switching mechanism of plane grating is described, and horizontal deviation, vertical deviation, roll angle precision, yaw angle precision and pitch angle precision are analyzed in detail; six-bar parallel mechanism is used for adjusting the UHV-chamber, and adjusting range and resolution of the bar are analyzed. The entire structure of monochromator is presented, and its precision testing is performed. Results show that the angular repeatability of plane mirror and plane grating are 0.166″ and 0.149″, and roll, yaw and pitch angular repeatability of plane grating switching mechanism are 0.08″, 0.12″ and 0.05″, indicating that structure design and precision of monochromator satisfy the technical demand.
引用
收藏
相关论文
共 50 条
  • [31] Design for microscopic soft X-ray beamline with diffraction-limited focusing
    Xiao, T.Q.
    He Jishu/Nuclear Techniques, 2001, 24 (07):
  • [32] HYBRID method simulations of a soft X-ray beamline
    Shi, Yingbo
    Shi, Xianbo
    Reininger, Ruben
    Ding, Hong
    Wang, Yong
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XIV, 2019, 11108
  • [33] Soft X-ray beamline for industry application in saga
    Kamada, M.
    Azuma, J.
    Takahashi, K.
    Kondo, Y.
    Miyata, H.
    Tsuji, J.
    Hashimoto, H.
    Yamashige, H.
    Kurisaki, S.
    Wakita, H.
    Furuya, K.
    Harata, A.
    Tochihara, H.
    Matsuo, S.
    Watanabe, T.
    Inaba, M.
    Okajima, T.
    Setoyama, H.
    Yoshimura, D.
    Fujimoto, H.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 623 - +
  • [34] Double crystal monochromator for x-ray undulator beamline at the PF-AR
    Kawata, H
    Mori, T
    Adachi, H
    Matsugaki, N
    Koyama, A
    Nomura, M
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 663 - 666
  • [35] Design and testing of deflecting mirror system of X-ray interference lithography beamline
    Lu, Qi-Peng, 1600, Chinese Academy of Sciences (22):
  • [36] X-ray optical beamline design principles
    Hart, M
    X-RAY AND NEUTRON DYNAMICAL DIFFRACTION: THEORY AND APPLICATIONS, 1996, 357 : 73 - 90
  • [37] Structure Design and Numerical Simulation of a High Performance Slit in Soft X-Ray Interference Lithography Beamline at SSRF
    Gong, Xuepeng
    Lu, Qipeng
    Peng, Zhongqi
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [38] Design of a transmission grating spectrometer and an undulator beamline for soft x-ray emission studies
    Hatsui, T
    Shigemasa, E
    Kosugi, N
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 921 - 924
  • [39] Design concept and performance of the soft X-ray beamline HiSOR-BL14
    Sawada, M.
    Yaji, K.
    Nagira, M.
    Kimura, A.
    Namatame, H.
    Taniguchi, M.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 551 - +
  • [40] From soft to hard X-ray with a single grating monochromator
    Cocco, D.
    Bianco, A.
    Kaulich, B.
    Schaefers, F.
    Mertin, M.
    Reichardt, G.
    Nelles, B.
    Heidemann, K. F.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 497 - +