Our objective is to validate the ability of 3 appropriately placed accelerometers to determine body position during ambulatory electrocardiographic (ECG) monitoring and to demonstrate the clinical applicability of this method. During ambulatory (Holter) monitoring, the ability to know a patient's position (lying down, sitting, standing, or changing from one position to another) is important in the evaluation of common symptoms such as dizziness, palpitations, and syncope. Changes in body position are also known to alter the electrical axis of the heart, resulting in artifactual changes in QRS amplitude and ST-segment morphology. We have developed an ambulatory patient-monitoring instrument that, through the use of microfabricated accelerometers, can simultaneously record body-position information and 2 channels of ECG data. The accelerometers measure the effects of gravity and dy@amic dynamic acceleration, allowing determination of a patient's orientation and movements. The accelerometer and ECG signals are input to a portable recorder and are filtered and digitized. Algorithms were developed to automatically determine body position. Ten healthy volunteers wore the device for 1 hour and followed a protocol of standing, sitting, walking, lying supine, and lying in the left and right lateral decubitus positions. An observer manually recorded times of position changes. Data were recorded and analyzed using software designed with MATLAB. The ability of the accelerometers and computer algorithms to determine body position was analyzed in terms of the sensitivity and specificity for each body position. The sensitivities for sitting, standing, walking, lying supine, lying right, and lying left were 98.8%, 99.2%, 95.5%, 99.1%, 98.9%, and 94.8%, respectively. The specificities were 99.7%, 99.4%, 99.6%, 99.0%, 99.8%, and 99.9%, respectively. The use of microfabricated accelerometers is a clinically feasible method to determine body position and can be applied to future studies correlating body position with ECG or other physiologic data.
引用
收藏
页码:338 / 346
相关论文
共 50 条
  • [41] A Wireless Accelerometer-Based Body Posture Stability Detection System and Its Application for Meditation Practitioners
    Chang, Kang-Ming
    Chen, Sih-Huei
    Lee, Hsin-Yi
    Ching, Congo Tak-Shing
    Huang, Chun-Lung
    SENSORS, 2012, 12 (12) : 17620 - 17632
  • [42] Prediction of 30-Day Readmission for COPD Patients Using Accelerometer-Based Activity Monitoring
    Lin, Wen-Yen
    Verma, Vijay Kumar
    Lee, Ming-Yih
    Lin, Horng-Chyuan
    Lai, Chao-Sung
    SENSORS, 2020, 20 (01)
  • [43] An Accelerometer-Based Real-Time Monitoring and Leak Detection System for Pressurized Water Pipelines
    El Zahab, Samer
    Mosleh, Fadi
    Zayed, Tarek
    PIPELINES 2016 - OUT OF SIGHT, OUT OF MIND, NOT OUT OF RISK, 2016, : 257 - 268
  • [44] B-CNN: a deep learning method for accelerometer-based fatigue cracks monitoring system
    Yanjie Zhu
    Hidehiko Sekiya
    Takayuki Okatani
    Masayuki Tai
    Shogo Morichika
    Journal of Civil Structural Health Monitoring, 2023, 13 : 947 - 959
  • [45] B-CNN: a deep learning method for accelerometer-based fatigue cracks monitoring system
    Zhu, Yanjie
    Sekiya, Hidehiko
    Okatani, Takayuki
    Tai, Masayuki
    Morichika, Shogo
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2023, 13 (4-5) : 947 - 959
  • [46] Physical activity monitoring by use of accelerometer-based body-worn sensors in older adults: A systematic literature review of current knowledge and applications
    Taraldsen, Kristin
    Chastin, Sebastien F. M.
    Riphagen, Ingrid I.
    Vereijken, Beatrix
    Helbostad, Jorunn L.
    MATURITAS, 2012, 71 (01) : 13 - 19
  • [47] Ambulatory Circadian Monitoring (ACM) based on Thermometry, motor Activity and body Position (TAP): A comparison with polysomnography
    Ortiz-Tudela, Elisabet
    Martinez-Nicolas, Antonio
    Albares, Javier
    Segarra, Francesc
    Campos, Manuel
    Estivill, Eduard
    Angeles Rol, Maria
    Antonio Madrid, Juan
    PHYSIOLOGY & BEHAVIOR, 2014, 126 : 30 - 38
  • [48] A MEMS accelerometer-based real-time motion-sensing module for urological diagnosis and treatment
    Xie, H. (hkxie@ece.ufl.edu), 2013, Informa Healthcare (37):
  • [49] ACCELEROMETER-BASED GESTURE RECOGNITION VIA DYNAMIC-TIME WARPING, AFFINITY PROPAGATION, & COMPRESSIVE SENSING
    Akl, Ahmad
    Valaee, Shahrokh
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 2270 - 2273
  • [50] Patient-focused endpoints in advanced cancer: Criterion-based validation of accelerometer-based activity monitoring
    Skipworth, Richard J. E.
    Stene, Guro B.
    Dahele, Max
    Hendry, Paul O.
    Small, Alexandra C.
    Blum, David
    Kaasa, Stein
    Trottenberg, Peter
    Radbruch, Lukas
    Strasser, Florian
    Preston, Tom
    Fearon, Kenneth C. H.
    Helbostad, Jorunn L.
    CLINICAL NUTRITION, 2011, 30 (06) : 812 - 821