Accelerometer-based body-position sensing for ambulatory electrocardiographic monitoring

被引:0
|
作者
Ng, Jason [1 ]
Sahakian, Alan V. [1 ,3 ]
Swiryn, Steven [2 ]
机构
[1] Dept. of Elec. and Comp. Engineering, Northwestern University, Evanston, IL, United States
[2] Feinburg School of Medicine, Northwestern University, Evanston, IL, United States
[3] Dept. of Elec. and Comp. Engineering, Northwestern University, 2145 Sheridan Rd., Evanston, IL 60208, United States
来源
关键词
Accelerometers - Algorithms - Computer software - Patient treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective is to validate the ability of 3 appropriately placed accelerometers to determine body position during ambulatory electrocardiographic (ECG) monitoring and to demonstrate the clinical applicability of this method. During ambulatory (Holter) monitoring, the ability to know a patient's position (lying down, sitting, standing, or changing from one position to another) is important in the evaluation of common symptoms such as dizziness, palpitations, and syncope. Changes in body position are also known to alter the electrical axis of the heart, resulting in artifactual changes in QRS amplitude and ST-segment morphology. We have developed an ambulatory patient-monitoring instrument that, through the use of microfabricated accelerometers, can simultaneously record body-position information and 2 channels of ECG data. The accelerometers measure the effects of gravity and dy@amic dynamic acceleration, allowing determination of a patient's orientation and movements. The accelerometer and ECG signals are input to a portable recorder and are filtered and digitized. Algorithms were developed to automatically determine body position. Ten healthy volunteers wore the device for 1 hour and followed a protocol of standing, sitting, walking, lying supine, and lying in the left and right lateral decubitus positions. An observer manually recorded times of position changes. Data were recorded and analyzed using software designed with MATLAB. The ability of the accelerometers and computer algorithms to determine body position was analyzed in terms of the sensitivity and specificity for each body position. The sensitivities for sitting, standing, walking, lying supine, lying right, and lying left were 98.8%, 99.2%, 95.5%, 99.1%, 98.9%, and 94.8%, respectively. The specificities were 99.7%, 99.4%, 99.6%, 99.0%, 99.8%, and 99.9%, respectively. The use of microfabricated accelerometers is a clinically feasible method to determine body position and can be applied to future studies correlating body position with ECG or other physiologic data.
引用
收藏
页码:338 / 346
相关论文
共 50 条
  • [31] Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position
    Masahiro Hasegawa
    Yohei Naito
    Shine Tone
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 23
  • [32] Noise-resilient feature selection for accelerometer-based guyed tower monitoring
    de Oliveira, Juliane Regina
    Jimenez, German Efrain Casteneda
    Ferreira, Janito Vaqueiro
    de Lima, Eduardo Rodrigues
    de Almeida, Larissa Medeiros
    Wanner, Lucas
    INTERNET OF THINGS, 2025, 31
  • [33] 3D Tilt Sensing by Using Accelerometer-based Wireless Sensor Networks
    Ishimwe Ngabo, Christophe
    El Beqqali, Omar
    2018 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND COMPUTER VISION (ISCV2018), 2018,
  • [34] Classification of behaviour in housed dairy cows using an accelerometer-based activity monitoring system
    Vázquez Diosdado J.A.
    Barker Z.E.
    Hodges H.R.
    Amory J.R.
    Croft D.P.
    Bell N.J.
    Codling E.A.
    Animal Biotelemetry, 3 (1)
  • [35] Accelerometer-Based Monitoring of Upper Limb Movement in Older Adults With Acute and Subacute Stroke
    Narai, Emi
    Hagino, Hiroshi
    Komatsu, Taiki
    Togo, Fumiharu
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2016, 39 (04) : 171 - 177
  • [36] Accelerometer-Based Human Activity Recognition for Patient Monitoring Using a Deep Neural Network
    Fridriksdottir, Esther
    Bonomi, Alberto G.
    SENSORS, 2020, 20 (22) : 1 - 13
  • [37] Accelerometer-based steering-wheel movement monitoring for drowsy-driving detection
    Lawoyin, Samuel
    Fei, Ding-Yu
    Bai, Ou
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2015, 229 (02) : 163 - 173
  • [38] Accelerometer-based position reconstruction for the feedforward compensation of fast telescope vibrations in the E-ELT/MICADO
    Keck, Alexander
    Pott, Jorg-Uwe
    Sawodny, Oliver
    GROUND-BASED AND AIRBORNE TELESCOPES V, 2014, 9145
  • [39] An Accelerometer-based Embedded System-on-Chip for Measuring Human-Body Joint Angles
    Caballero, A. D.
    Cabrera Lopez, J. J.
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [40] Fabrication and assembly of MEMS accelerometer-based heart monitoring device with simplified, one step placement
    Tjulkins, Fjodors
    Nguyen, Anh-Tuan Thai
    Andreassen, Erik
    Aasmundtveit, Knut
    Hoivik, Nils
    Hoff, Lars
    Halvorsen, Per Steinar
    Grymyr, Ole-Johannes
    Imenes, Kristin
    Journal of Medical Engineering and Technology, 2015, 39 (01): : 69 - 74