Accelerometer-based body-position sensing for ambulatory electrocardiographic monitoring

被引:0
|
作者
Ng, Jason [1 ]
Sahakian, Alan V. [1 ,3 ]
Swiryn, Steven [2 ]
机构
[1] Dept. of Elec. and Comp. Engineering, Northwestern University, Evanston, IL, United States
[2] Feinburg School of Medicine, Northwestern University, Evanston, IL, United States
[3] Dept. of Elec. and Comp. Engineering, Northwestern University, 2145 Sheridan Rd., Evanston, IL 60208, United States
来源
关键词
Accelerometers - Algorithms - Computer software - Patient treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective is to validate the ability of 3 appropriately placed accelerometers to determine body position during ambulatory electrocardiographic (ECG) monitoring and to demonstrate the clinical applicability of this method. During ambulatory (Holter) monitoring, the ability to know a patient's position (lying down, sitting, standing, or changing from one position to another) is important in the evaluation of common symptoms such as dizziness, palpitations, and syncope. Changes in body position are also known to alter the electrical axis of the heart, resulting in artifactual changes in QRS amplitude and ST-segment morphology. We have developed an ambulatory patient-monitoring instrument that, through the use of microfabricated accelerometers, can simultaneously record body-position information and 2 channels of ECG data. The accelerometers measure the effects of gravity and dy@amic dynamic acceleration, allowing determination of a patient's orientation and movements. The accelerometer and ECG signals are input to a portable recorder and are filtered and digitized. Algorithms were developed to automatically determine body position. Ten healthy volunteers wore the device for 1 hour and followed a protocol of standing, sitting, walking, lying supine, and lying in the left and right lateral decubitus positions. An observer manually recorded times of position changes. Data were recorded and analyzed using software designed with MATLAB. The ability of the accelerometers and computer algorithms to determine body position was analyzed in terms of the sensitivity and specificity for each body position. The sensitivities for sitting, standing, walking, lying supine, lying right, and lying left were 98.8%, 99.2%, 95.5%, 99.1%, 98.9%, and 94.8%, respectively. The specificities were 99.7%, 99.4%, 99.6%, 99.0%, 99.8%, and 99.9%, respectively. The use of microfabricated accelerometers is a clinically feasible method to determine body position and can be applied to future studies correlating body position with ECG or other physiologic data.
引用
收藏
页码:338 / 346
相关论文
共 50 条
  • [21] Control of Combustion Phasing Using Accelerometer-Based Non-Intrusive Sensing
    Govind Raju, Sathya Aswath
    Reisetter, Mitchell
    Miganakallu, Niranjan
    Stafford, Jacob
    Sun, Zongxuan
    Rothamer, David
    Kim, Kenneth
    Kweon, Chol-Bum Mike
    ASME Letters in Dynamic Systems and Control, 2024, 4 (04):
  • [22] An Accelerometer-Based Sensing System to Study the Valve-Gaping Behavior of Bivalves
    Ahmmed, Parvez
    Reynolds, James
    Levine, Jay F.
    Bozkurt, Alper
    IEEE SENSORS LETTERS, 2021, 5 (04)
  • [23] Effect of Body Position and Support Surface on the Postural Control Challenge During the Pallof Press Exercise: A Smartphone Accelerometer-Based Study
    Juan-Recio, Casto
    Prat-Luri, Amaya
    Rondon-Espinosa, Heidy
    Barbado, David
    Vera-Garcia, Francisco J.
    MEDICINA-LITHUANIA, 2025, 61 (02):
  • [24] Accelerometer-based Tilt Estimation of a Rigid Body with only Rotational Degrees of Freedom
    Trimpe, Sebastian
    D'Andrea, Raffaello
    2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, : 2630 - 2636
  • [25] A feasibility study on smartphone accelerometer-based recognition of household activities and influence of smartphone position
    Della Mea, Vincenzo
    Quattrin, Omar
    Parpinel, Maria
    INFORMATICS FOR HEALTH & SOCIAL CARE, 2017, 42 (04): : 321 - 334
  • [26] Accelerometer-based muscle-stimulation neuromuscular blockade monitoring: A pilot study
    William McKay
    Ayoub Dangor
    Garrett Chin
    Canadian Journal of Anaesthesia, 2008, 55 (Suppl 1) : 4500191 - 4500192
  • [27] Use of accelerometer-based activity monitoring in orthopaedics: benefits, impact and practical considerations
    Sliepen, Maik
    Lipperts, Matthijs
    Tjur, Marianne
    Mechlenburg, Inger
    EFORT OPEN REVIEWS, 2019, 4 (12): : 678 - 685
  • [28] Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [29] An Implantable Accelerometer-Based Heart-Monitoring Device With Improved Positional Stability
    Tjulkins, Fjodors
    Anh-Tuan Thai Nguyen
    Andreassen, Erik
    Hoff, Lars
    Grymyr, Ole-Johannes
    Halvorsen, Per Steinar
    Imenes, Kristin
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (04):
  • [30] SmarTEG: An Autonomous Wireless Sensor Node for High Accuracy Accelerometer-Based Monitoring
    Magno, Michele
    Sigrist, Lukas
    Gomez, Andres
    Cavigelli, Lukas
    Libri, Antonio
    Popovici, Emanuel
    Benini, Luca
    SENSORS, 2019, 19 (12)