Development of multichannel ellipsometry with synchronously rotating polarizer and analyzer

被引:0
|
作者
An, Ilsin [1 ,2 ]
Park, Myung-Gyu [1 ,2 ]
Bang, Kyung-Yoon [1 ,2 ]
Oh, Hye-Keun [1 ,2 ]
Kim, Hanjung [1 ,2 ]
机构
[1] Department of Physics, Hanyang University, Ansan 425-791, Korea, Republic of
[2] Department of Control and Instrumentation, Hankyong National University, Ansung 456-749, Korea, Republic of
关键词
Calibration - Data acquisition - Discrete Fourier transforms - Shafts (machine components);
D O I
10.1143/jjap.41.3978
中图分类号
学科分类号
摘要
Rotating-polarizer-and-analyzer-ellipsometry was developed with a multichannel detector. In this system, the transmission axes of the polarizer and analyzer rotated in phase using a flexible shaft for mechanical connection. With this configuration, autocalibration for the azimuths of the polarizer and analyzer was achieved. Thus, experimental error related to the calibration could be avoided and spectroscopic ellipsometry with the simplest operation principle was realized. Data acquisition time for 512-point ellipsometry spectra was 3 s over the photon energy range of 1.5 to 4.5 eV.
引用
收藏
页码:3978 / 3980
相关论文
共 50 条
  • [41] Fixed polarizer, rotating-polarizer and fixed analyzer spectroscopic ellipsometer: accurate calibration method, effect of errors and testing
    Naciri, AE
    Broch, L
    Johann, L
    Kleim, R
    THIN SOLID FILMS, 2002, 406 (1-2) : 103 - 112
  • [42] Determination of the optical functions of various liquids by rotating compensator multichannel spectroscopic ellipsometry
    Bang, KY
    Lee, S
    Oh, H
    An, I
    Lee, H
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2005, 26 (06): : 947 - 951
  • [43] Software development for a multichannel neutral particle analyzer
    Song, Xianming
    Zhang, Jiquan
    Zhong, Guangwu
    Hejubian Yu Dengliziti Wuli/Nuclear Fusion and Plasma Physics, 18 (03): : 61 - 64
  • [44] Optimization of azimuth angle settings in polarizer-compensator-sample-analyzer off-null ellipsometry
    Wang, GL
    Arwin, H
    Jansson, R
    APPLIED OPTICS, 2003, 42 (01) : 38 - 44
  • [45] Optimization of azimuth angle settings in polarizer-compensator-sample-analyzer off-null ellipsometry
    Wang, Guoliang
    Arwin, Hans
    Jansson, Roger
    Applied Optics, 2003, 42 (01): : 38 - 44
  • [46] A spectroscopic ellipsometer using rotating polarizer and analyzer at a speed ratio 1:1 and a compensator
    Taya, Sofyan A.
    El-Agez, Taher M.
    Alkanoo, Anas A.
    OPTICAL AND QUANTUM ELECTRONICS, 2014, 46 (07) : 883 - 895
  • [47] Development of infrared spectroscopic ellipsometer by synchronous rotation of the polarizer and analyzer
    Huang, ZM
    Jin, SR
    Chen, SW
    Chen, MH
    Shi, GL
    Chen, LY
    Chu, JH
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 1998, 17 (05) : 321 - 326
  • [48] Ellipsometric configurations using a phase retarder and a rotating polarizer and analyzer at any speed ratio
    Taya, Sofyan A.
    El-Agez, Taher M.
    Alkanoo, Anas A.
    CHINESE PHYSICS B, 2012, 21 (11)
  • [49] Total retardance measurements based on the complex Fourier coefficients for the rotating polarizer analyzer system
    Parra-Escamilla, Geliztle A.
    Cervantes-L, Joel
    Flores, Jorge L.
    Serrano-Garcia, David I.
    HELIYON, 2023, 9 (06)
  • [50] A spectroscopic ellipsometer using rotating polarizer and analyzer at a speed ratio 1:1 and a compensator
    Sofyan A. Taya
    Taher M. El-Agez
    Anas A. Alkanoo
    Optical and Quantum Electronics, 2014, 46 : 883 - 895