摘要
Rotating-polarizer-and-analyzer-ellipsometry was developed with a multichannel detector. In this system, the transmission axes of the polarizer and analyzer rotated in phase using a flexible shaft for mechanical connection. With this configuration, autocalibration for the azimuths of the polarizer and analyzer was achieved. Thus, experimental error related to the calibration could be avoided and spectroscopic ellipsometry with the simplest operation principle was realized. Data acquisition time for 512-point ellipsometry spectra was 3 s over the photon energy range of 1.5 to 4.5 eV.
引用
收藏
页码:3978 / 3980
相关论文
共 50 条
  • [31] Retardance Parameters Measurements By Employing A Rotating Polarizer-Analyzer Polarimeter
    Macias-Mendoza, Humberto
    Serrano-Garcia, David I.
    Flores, Jorge L.
    Garcia Torales, Guillermo
    Mora-Nunez, Azael
    Santiago Hernandez, Hector
    Parra Escamilla, Geliztle A.
    Cervantes Lozano, Francisco J.
    POLARIZATION SCIENCE AND REMOTE SENSING IX, 2019, 11132
  • [32] Approach to Error Analysis and Reduction for Rotating-Polarizer-Analyzer Ellipsometer
    Mao, Peng-Hui
    Zheng, Yu-Xiang
    Cai, Qing-Yuan
    Zhang, Dong-Xu
    Zhang, Rong-Jun
    Zhao, Hai-Bin
    Chen, Liang-Yao
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2012, 81 (12)
  • [33] DEVELOPMENT OF A MULTICHANNEL ELECTROCHEMICAL CENTRIFUGAL ANALYZER
    CHO, HK
    LEE, YH
    COUCH, RA
    JAGADEESH, JM
    OLSON, CL
    CLINICAL CHEMISTRY, 1982, 28 (09) : 1956 - 1961
  • [34] INFRARED ROTATING-ANALYZER ELLIPSOMETRY - CALIBRATION AND DATA-PROCESSING
    YAKOVLEV, VA
    LI, M
    IRENE, EA
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (03): : 509 - 514
  • [35] Noise Effect on Thin Film Characterization Using Rotating Polarizer Analyzer Ellipsometer
    El-Agez, T. M.
    Taya, S. A.
    ACTA PHYSICA POLONICA A, 2012, 122 (01) : 15 - 19
  • [36] A Fourier Ellipsometer Using Rotating Polarizer and Analyzer at a Speed Ratio 1: 1
    El-Agez, Taher M.
    Taya, Sofyan A.
    JOURNAL OF SENSORS, 2010, 2010
  • [37] Accurate calibration and optimized measurement: use of an achromatic compensator in rotating polarizer spectroscopic ellipsometry
    Broch, L
    Naciri, AE
    Johann, L
    THIN SOLID FILMS, 2004, 455 : 61 - 65
  • [38] Detection of living-cell reaction by means of ellipsometry with rotating analyzer
    Yanase, Y.
    Araki, A.
    Kajikawa, K.
    Suzuki, H.
    Hide, M.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2008, 128 : S135 - S135
  • [39] An Improvement of Scanning Ellipsometer by Rotating a Polarizer and an Analyzer at a Speed Ratio of 1:3
    El-Agez, Taher M.
    Taya, Sofyan A.
    El Tayyan, Ahmed A.
    INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2011, 5 (01) : 51 - 67
  • [40] Polarizer–analyzer optics
    E.E. Alp
    W. Sturhahn
    T.S. Toellner
    Hyperfine Interactions, 2000, 125 : 45 - 68