Common path optical coherence tomographic system suitable for endoscopic imaging

被引:0
|
作者
Yang, Yaliang [1 ]
Ding, Zhihua [1 ]
Meng, Jie [1 ]
Wu, Lan [1 ]
He, Zi'ang [1 ]
Wu, Tong [1 ]
Chen, Minghui [1 ]
机构
[1] State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2008年 / 28卷 / 05期
关键词
Medical imaging - Michelson interferometers - Endoscopy;
D O I
暂无
中图分类号
学科分类号
摘要
A Fizeau interferometer based optical coherence tomographic (OCT) system using a fiber-based Michelson interferometer to compensate the optical path difference between the reference and sample light in the Fizeau interferometer is presented. The sensing probe of the system is a common path interferometer which can solve the problems existing in current endoscopic OCT systems, such as image distortion due to probe motion, and dispersion and polarization matching which are required when various probes are used. Experiments of path length compensation and vibration are conducted and the results demonstrate that this path length compensation method is feasible and the system can avoid environmental turbulences. Mirror and infrared card are imaged to demonstrate the performance of the proposed OCT system. This imaging approach is thus very suitable for endoscopic imaging, and the detailed method of expanding the OCT system for endoscopic OCT imaging is also presented.
引用
收藏
页码:956 / 959
相关论文
共 50 条
  • [41] In vivo imaging in the oral cavity by endoscopic optical coherence tomography
    Walther, Julia
    Schnabel, Christian
    Tetschke, Florian
    Rosenauer, Tobias
    Golde, Jonas
    Ebert, Nadja
    Baumann, Michael
    Hannig, Christian
    Koch, Edmund
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (07)
  • [42] Dual-path handheld system for cornea and retina imaging using optical coherence tomography
    Muhammad Faizan Shirazi
    Ruchire Eranga Wijesinghe
    Naresh Kumar Ravichandran
    Pilun Kim
    Mansik Jeon
    Jeehyun Kim
    Optical Review, 2017, 24 : 219 - 225
  • [43] Endoscopic Optical Coherence Tomography (OCT): Advances in Gastrointestinal Imaging
    Kirtane, Tejas S.
    Wagh, Mihir S.
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [44] Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis
    Kwon, Daa Young
    Oak, Chulho
    Ahn, Yeh-Chan
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2019, 30 (06) : 243 - 248
  • [45] Probe alignment and design issues of microelectromechanical system based optical coherence tomography endoscopic imaging
    Duan, Can
    Sun, Jingjing
    Samuelson, Sean
    Xie, Huikai
    APPLIED OPTICS, 2013, 52 (26) : 6589 - 6598
  • [46] Distal-scanning common path probe for optical coherence tomography
    Chen, Zhengyu
    He, Bin
    Yin, Zichen
    Hu, Zhangwei
    Shi, Yejiong
    Wang, Chengming
    Zhang, Xiao
    Zhang, Ning
    Jing, Linkai
    Wang, Guihuai
    Xue, Ping
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2024, 17 (03)
  • [47] Polymer microlens fiber probe for Common Path Optical Coherence Tomography
    Xiao, Hai
    Zhang, Yinan
    Pieonkowski, Edward
    Wei, Tao
    Lan, Xinwei
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [48] All-fiber common-path optical coherence tomography: Sensitivity optimization and system analysis
    Sharma, U
    Fried, NM
    Kang, JU
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2005, 11 (04) : 799 - 805
  • [49] Common path optical coherence tomography with electronic feedback for improved sensitivity
    Alsnaie, Khalid
    OPTICA APPLICATA, 2023, 53 (03) : 495 - 504
  • [50] Endoscopic optical coherence tomography system with rotating scan
    Chen Xiaodong
    Li Qiao
    Li Wanhui
    Wang Yi
    Yu Daoyin
    SIGNAL ANALYSIS, MEASUREMENT THEORY, PHOTO-ELECTRONIC TECHNOLOGY, AND ARTIFICIAL INTELLIGENCE, PTS 1 AND 2, 2006, 6357