Common path optical coherence tomographic system suitable for endoscopic imaging

被引:0
|
作者
Yang, Yaliang [1 ]
Ding, Zhihua [1 ]
Meng, Jie [1 ]
Wu, Lan [1 ]
He, Zi'ang [1 ]
Wu, Tong [1 ]
Chen, Minghui [1 ]
机构
[1] State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2008年 / 28卷 / 05期
关键词
Medical imaging - Michelson interferometers - Endoscopy;
D O I
暂无
中图分类号
学科分类号
摘要
A Fizeau interferometer based optical coherence tomographic (OCT) system using a fiber-based Michelson interferometer to compensate the optical path difference between the reference and sample light in the Fizeau interferometer is presented. The sensing probe of the system is a common path interferometer which can solve the problems existing in current endoscopic OCT systems, such as image distortion due to probe motion, and dispersion and polarization matching which are required when various probes are used. Experiments of path length compensation and vibration are conducted and the results demonstrate that this path length compensation method is feasible and the system can avoid environmental turbulences. Mirror and infrared card are imaged to demonstrate the performance of the proposed OCT system. This imaging approach is thus very suitable for endoscopic imaging, and the detailed method of expanding the OCT system for endoscopic OCT imaging is also presented.
引用
收藏
页码:956 / 959
相关论文
共 50 条
  • [21] An Optical coherence tomographic imaging system for investigating cortical fuctional organization of brain: a simulation study
    Maheswari, RU
    Kadono, H
    Tanifuji, M
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 400 - 401
  • [22] All-Fiber Common-Path Fourier-Domain Optical Coherence Microscopy for 3D In Vivo Endoscopic Subcellular Imaging
    Zhang, Kang
    Han, Jae-Ho
    Kang, Jin U.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 3139 - 3140
  • [23] Trimodality imaging system and intravascular endoscopic probe: combined optical coherence tomography, fluorescence imaging and ultrasound imaging
    Liang, Shanshan
    Ma, Teng
    Jing, Joseph
    Li, Xiang
    Li, Jiawen
    Shung, K. Kirk
    Zhou, Qifa
    Zhang, Jun
    Chen, Zhongping
    OPTICS LETTERS, 2014, 39 (23) : 6652 - 6655
  • [24] Endoscopic optical coherence tomography for imaging the tympanic membrane
    Burkhardt, Anke
    Walther, Julia
    Cimalla, Peter
    Bornitz, Matthias
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [25] Design of endoscopic optical coherence tomography system
    Yu, DY
    Li, WH
    Wang, Y
    Chen, XD
    ICO20: BIOMEDICAL OPTICS, 2006, 6026
  • [26] Astigmatism Corrected Common Path Probe for Optical Coherence Tomography
    Singh, Kanwarpal
    Yamada, Daisuke
    Tearney, Guillermo
    LASERS IN SURGERY AND MEDICINE, 2017, 49 (03) : 312 - 318
  • [27] Common path optical coherence tomography with fibre bundle probe
    Han, J. -H.
    Liu, X.
    Song, C. G.
    Kang, J. U.
    ELECTRONICS LETTERS, 2009, 45 (22) : 1110 - 1111
  • [28] Optical coherence tomography endoscopic imaging system using mini-ultrasonic motor
    Li, Qiao
    Gao, Changlei
    Wang, Yi
    Chen, Xiaodong
    Yu, Daoyin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS III, 2008, 6826 : U42 - U51
  • [29] Snapshot Coherence Tomographic Imaging
    Qiao, Mu
    Sun, Yangyang
    Ma, Jiawei
    Meng, Ziyi
    Liu, Xuan
    Yuan, Xin
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2021, 7 : 624 - 637
  • [30] Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
    Sharma, Utkarsh
    Kang, Jin U.
    CHINESE OPTICS LETTERS, 2008, 6 (12) : 910 - 912