Common path optical coherence tomography with electronic feedback for improved sensitivity

被引:0
|
作者
Alsnaie, Khalid [1 ]
机构
[1] Imam Mohammad Ibn Saud Islamic Univ, Fac Engn, Elect Engn Dept, Riyadh, Saudi Arabia
关键词
optical coherence tomography; frequency domain OCT; medical imaging; partially coherent interferometers; B-scan;
D O I
10.37190/oa230312
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) imaging has become a useful tool in medical diagnosis over the past 25 years, because of its ability to visualize intracellular structures at high resolution. The main objective of this work is to add electronic feedback to the optical coherence tomography setup to increase its sensitivity. Noise added to the measured interferogram obscures some details of ex-amined tissue layered structure. Adjusting signal power level in such a way to improve signal-to-noise ratio can help to enhance image quality. Electronic feedback is added to enhance system sen-sitivity. A logarithmic amplifier is included in the OCT setup to automatically adapt signal level. Moreover, the resolution of the optical spectrum analyzer is controlled according to the farthest layer detected in the A-scan. These techniques are tested showing an improvement in obtained im-age of a human nail.
引用
收藏
页码:495 / 504
页数:10
相关论文
共 50 条
  • [1] Astigmatism Corrected Common Path Probe for Optical Coherence Tomography
    Singh, Kanwarpal
    Yamada, Daisuke
    Tearney, Guillermo
    LASERS IN SURGERY AND MEDICINE, 2017, 49 (03) : 312 - 318
  • [2] Common path optical coherence tomography with fibre bundle probe
    Han, J. -H.
    Liu, X.
    Song, C. G.
    Kang, J. U.
    ELECTRONICS LETTERS, 2009, 45 (22) : 1110 - 1111
  • [3] Common path endoscopic optical coherence tomography with outside path length compensation
    Yang, Yaliang
    Ding, Zhihua
    Meng, Jie
    Wu, Lan
    He, Zi'ang
    Wu, Tong
    Chen, Minghui
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS III, 2008, 6826
  • [4] All-fiber common-path optical coherence tomography: Sensitivity optimization and system analysis
    Sharma, U
    Fried, NM
    Kang, JU
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2005, 11 (04) : 799 - 805
  • [5] Distal-scanning common path probe for optical coherence tomography
    Chen, Zhengyu
    He, Bin
    Yin, Zichen
    Hu, Zhangwei
    Shi, Yejiong
    Wang, Chengming
    Zhang, Xiao
    Zhang, Ning
    Jing, Linkai
    Wang, Guihuai
    Xue, Ping
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2024, 17 (03)
  • [6] Polymer microlens fiber probe for Common Path Optical Coherence Tomography
    Xiao, Hai
    Zhang, Yinan
    Pieonkowski, Edward
    Wei, Tao
    Lan, Xinwei
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [7] Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2010, 14 (01) : 1 - 13
  • [8] Common path endoscopic probes for optical coherence tomography (Conference Presentation)
    Singh, Kanwarpal
    Gardecki, Joseph A.
    Tearney, Guillermo J.
    ENDOSCOPIC MICROSCOPY XII, 2017, 10040
  • [9] Truncated Conical-Tip Fiber Probe for Common-Path Optical Coherence Tomography With Optimal Sensitivity
    Wang, Wei
    Ma, Jun
    Guan, Bai-Ou
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (12) : 3974 - 3979
  • [10] Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography
    Sharma, Utkarsh
    Kang, Jin U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (11):