Common path optical coherence tomography with electronic feedback for improved sensitivity

被引:0
|
作者
Alsnaie, Khalid [1 ]
机构
[1] Imam Mohammad Ibn Saud Islamic Univ, Fac Engn, Elect Engn Dept, Riyadh, Saudi Arabia
关键词
optical coherence tomography; frequency domain OCT; medical imaging; partially coherent interferometers; B-scan;
D O I
10.37190/oa230312
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) imaging has become a useful tool in medical diagnosis over the past 25 years, because of its ability to visualize intracellular structures at high resolution. The main objective of this work is to add electronic feedback to the optical coherence tomography setup to increase its sensitivity. Noise added to the measured interferogram obscures some details of ex-amined tissue layered structure. Adjusting signal power level in such a way to improve signal-to-noise ratio can help to enhance image quality. Electronic feedback is added to enhance system sen-sitivity. A logarithmic amplifier is included in the OCT setup to automatically adapt signal level. Moreover, the resolution of the optical spectrum analyzer is controlled according to the farthest layer detected in the A-scan. These techniques are tested showing an improvement in obtained im-age of a human nail.
引用
收藏
页码:495 / 504
页数:10
相关论文
共 50 条
  • [41] Quantitative measurements of strain and birefringence with common-path polarization-sensitive optical coherence tomography
    Marvdashti, Tahereh
    Duan, Lian
    Lurie, Kristen L.
    Smith, Gennifer T.
    Ellerbee, Audrey K.
    OPTICS LETTERS, 2014, 39 (19) : 5507 - 5510
  • [42] Use of common path phase sensitive spectral domain optical coherence tomography for refractive index measurements
    Verma, Yogesh
    Nandi, Purnananda
    Rao, K. Divakar
    Sharma, Mrinalini
    Gupta, Pradeep Kumar
    APPLIED OPTICS, 2011, 50 (25) : E7 - E12
  • [43] In-fiber common-path optical coherence tomography using a conical-tip fiber
    Tan, K. M.
    Mazilu, M.
    Chow, T. H.
    Lee, W. M.
    Taguchi, K.
    Ng, B. K.
    Sibbett, W.
    Herrington, C. S.
    Brown, C. T. A.
    Dholakia, K.
    OPTICS EXPRESS, 2009, 17 (04): : 2375 - 2384
  • [44] Low cost scalable monolithic common path probe design for the application in endoscopic optical coherence tomography
    Blessing, Katharina
    Sharma, Shivani
    Gumann, Alexander
    Singh, Kanwarpal
    ENGINEERING RESEARCH EXPRESS, 2019, 1 (02):
  • [45] Common-path optical coherence tomography using a microelectromechanical-system-based endoscopic probe
    Wang, Donglin
    Duan, Can
    Zhang, Xiaoyang
    Yun, Zhao
    Pozzi, Antonio
    Xie, Huikai
    APPLIED OPTICS, 2016, 55 (25) : 6930 - 6935
  • [46] Tissue characterization using axicon probe-assisted common-path optical coherence tomography
    Gupta, Pooja
    Vairagi, Kaushal
    Sharma, Vishal
    Prasad, Kaushal Kishore
    Mondal, Samirk
    OPTICS EXPRESS, 2024, 32 (11): : 20194 - 20206
  • [47] Swept-source common-path optical coherence tomography with a MEMS endoscopic imaging probe
    Duan, Can
    Wang, Donglin
    Zhou, Zhengwei
    Liang, Peng
    Samuelson, Sean R.
    Pozzi, Antonio
    Xie, Huikai
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [48] Long-optical-path scanning mechanism for optical coherence tomography
    Shiina, T
    Moritani, Y
    Ito, M
    Okamura, Y
    APPLIED OPTICS, 2003, 42 (19) : 3795 - 3799
  • [49] Common-path diffraction optical tomography with a low-coherence illumination for reducing speckle noise
    Shin, Seungwoo
    Kim, Youngchan
    Lee, KyeoReh
    Kim, Kyoohyun
    Kim, Young-Jin
    Park, HyunJoo
    Park, YongKeun
    QUANTITATIVE PHASE IMAGING, 2015, 9336
  • [50] Long-optical-path scanning mechanism for optical coherence tomography
    Shiina, Tatsuo
    Moritani, Yohei
    Ito, Masafumi
    Okamura, Yasuyuki
    Applied Optics, 2003, 42 (19): : 3795 - 3799