Common-path diffraction optical tomography with a low-coherence illumination for reducing speckle noise

被引:10
|
作者
Shin, Seungwoo [1 ]
Kim, Youngchan [2 ]
Lee, KyeoReh [1 ]
Kim, Kyoohyun [1 ]
Kim, Young-Jin [3 ]
Park, HyunJoo [1 ]
Park, YongKeun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Phys, Taejon 305701, South Korea
[2] Univ London Imperial Coll Sci Technol & Med, Dept Phys, Photon Grp, London SW7 2AZ, England
[3] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
QUANTITATIVE PHASE IMAGING | 2015年 / 9336卷
关键词
Optical diffraction tomography; incoherent quantitative phase imaging; speckle noise reduction; PHASE MICROSCOPY; SPATIAL COHERENCE; DYNAMICS; FIELD;
D O I
10.1117/12.2175845
中图分类号
TH742 [显微镜];
学科分类号
摘要
Common-path diffraction optical tomography (cDOT) is a non-invasive and label-free optical holographic technique for measuring both the three-dimensional refractive index (RI) tomograms and two-dimensional dynamic phase images of a sample. Due to common-path geometry, cDOT provides quantitative phase imaging with high phase sensitivity. However, the image quality of the cDOT suffers from speckle noise; the use of a monochromatic laser inevitably results in the formation of parasitic fringe patterns in measured quantitative phase images. Here, we present a technique to reduce speckle noise in the cDOT using a low-coherence illumination source. Utilizing a Ti-sapphire pulsed laser in the cDOT, we achieved the reduction of speckle noise in both the three-dimensional RI tomograms and two-dimensional dynamic phase images.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Common-path intrinsically achromatic optical diffraction tomography
    Zdankowski, Piotr
    Winnik, Julianna
    Patorski, Krzysztof
    Goclowski, Pawel
    Ziemczonok, Michal
    Jozwik, Michal
    Kujawinska, Malgorzata
    Trusiak, Maciej
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (07) : 4219 - 4234
  • [2] Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2010, 14 (01) : 1 - 13
  • [3] Speckle Reduction during All-Fiber Common-Path Optical Coherence Tomography of the Cavernous Nerves
    Chitchian, Shahab
    Fiddy, Michael
    Fried, Nathaniel M.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168
  • [4] Double common-path interferometer for flexible optical probe of optical coherence tomography
    Park, Jae Seok
    Chen, Zhongping
    Jeong, Myung Yung
    Kim, Chang-Seok
    OPTICS EXPRESS, 2012, 20 (02): : 1102 - 1112
  • [5] Optimization of an angled fiber probe for common-path optical coherence tomography
    Liu, Xuan
    Kang, Jin U.
    OPTICS LETTERS, 2013, 38 (15) : 2660 - 2662
  • [6] Common-path optical coherence tomography guided vertical pneumodissection for DALK
    Wang, Yaning
    Guo, Shoujing
    Opfermann, Justin D.
    Kaluna, James
    Gensheimer, Bill G.
    Krieger, Axel
    Kang, Jin U.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS, TREATMENT AND ENVIRONMENTAL APPLICATIONS XXIII, 2023, 12372
  • [7] Common-path interferometer for frequency-domain optical coherence tomography
    Vakhtin, AB
    Kane, DJ
    Wood, WR
    Peterson, KA
    APPLIED OPTICS, 2003, 42 (34) : 6953 - 6958
  • [8] Common-path low-coherence interferometry fiber-optic sensor guided microincision
    Zhang, Kang
    Kang, Jin U.
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)
  • [9] Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography
    Li, Xiaolu
    Han, Jae-Ho
    Liu, Xuan
    Kang, Jin U.
    APPLIED OPTICS, 2008, 47 (27) : 4833 - 4840
  • [10] Long-range common-path spectral domain optical coherence tomography
    Wang, Chen
    Zhang, Qiankun
    Wang, Yimin
    Zhang, Xiangyang
    Zhang, Linna
    OPTICS EXPRESS, 2019, 27 (09): : 12483 - 12490