Common-path diffraction optical tomography with a low-coherence illumination for reducing speckle noise

被引:10
|
作者
Shin, Seungwoo [1 ]
Kim, Youngchan [2 ]
Lee, KyeoReh [1 ]
Kim, Kyoohyun [1 ]
Kim, Young-Jin [3 ]
Park, HyunJoo [1 ]
Park, YongKeun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Phys, Taejon 305701, South Korea
[2] Univ London Imperial Coll Sci Technol & Med, Dept Phys, Photon Grp, London SW7 2AZ, England
[3] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
QUANTITATIVE PHASE IMAGING | 2015年 / 9336卷
关键词
Optical diffraction tomography; incoherent quantitative phase imaging; speckle noise reduction; PHASE MICROSCOPY; SPATIAL COHERENCE; DYNAMICS; FIELD;
D O I
10.1117/12.2175845
中图分类号
TH742 [显微镜];
学科分类号
摘要
Common-path diffraction optical tomography (cDOT) is a non-invasive and label-free optical holographic technique for measuring both the three-dimensional refractive index (RI) tomograms and two-dimensional dynamic phase images of a sample. Due to common-path geometry, cDOT provides quantitative phase imaging with high phase sensitivity. However, the image quality of the cDOT suffers from speckle noise; the use of a monochromatic laser inevitably results in the formation of parasitic fringe patterns in measured quantitative phase images. Here, we present a technique to reduce speckle noise in the cDOT using a low-coherence illumination source. Utilizing a Ti-sapphire pulsed laser in the cDOT, we achieved the reduction of speckle noise in both the three-dimensional RI tomograms and two-dimensional dynamic phase images.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Handheld optical coherence tomography scanner using a common-path probing arm with long working distance
    Zhou, Song
    Yang, Wen
    Wang, Yimin
    Chen, Zhong
    Yuan, Tianran
    OPTICS COMMUNICATIONS, 2021, 499
  • [42] Downward viewing common-path optical coherence tomography guided hydro-dissection needle for DALK
    Guo, Shoujing
    Opfermann, Justin
    Gensheimer, William G.
    Krieger, Axel
    Kang, Jin U.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS, TREATMENT AND ENVIRONMENTAL APPLICATIONS XXII, 2022, 11953
  • [43] Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography
    Park, Jae Seok
    Jeong, Myung Yung
    Kim, Chang-Seok
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2011, 15 (04) : 380 - 385
  • [44] Simultaneous 0.8, 1.0, and 1.3 μm multispectral and common-path broadband source for optical coherence tomography
    Tsai, Meng-Tsan
    Chan, Ming-Che
    OPTICS LETTERS, 2014, 39 (04) : 865 - 868
  • [45] A common-path optical coherence tomography based electrode for structural imaging of nerves and recording of action potentials
    Islam, M. Shahidul
    Haque, Md Rezuanul
    Oh, Christian M.
    Wang, Yan
    Park, B. Hyle
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [46] Sapphire ball lensed fiber probe for common-path optical coherence tomography in ocular imaging and sensing
    Zhao, Mingtao
    Huang, Yong
    Kang, Jin U.
    OPHTHALMIC TECHNOLOGIES XXIII, 2013, 8567
  • [47] Common-path diffraction optical tomography for investigation of three-dimensional structures and dynamics of biological cells
    Kim, Youngchan
    Shim, Hyoeun
    Kim, Kyoohyun
    Park, HyunJoo
    Heo, Ji Han
    Yoon, Jonghee
    Choi, Chulhee
    Jang, Seongsoo
    Park, YongKeun
    OPTICS EXPRESS, 2014, 22 (09): : 10398 - 10407
  • [48] Low-coherence optical diffraction tomography using a ferroelectric liquid crystal spatial light modulator
    Park, Chansuk
    Lee, KyeoReh
    Baek, Yoonseok
    Park, YongKeun
    OPTICS EXPRESS, 2020, 28 (26) : 39649 - 39659
  • [49] Measurement of selected characteristics of low-coherence optical signal sources for Optical Coherence Tomography
    Jedrzejewska-Szczerska, M
    Hypszer, R
    Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments III, 2005, 5775 : 642 - 647
  • [50] Common-path Fourier-domain optical coherence tomography with a fiber optic probe integrated into a surgical needle
    Han, Jae-Ho
    Balicki, Marcin
    Zhang, Kang
    Liu, Xuan
    Handa, James
    Taylor, Russell
    Kang, Jin U.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 339 - +