Estimation of vertical interaction force to the end of a surgical instrument by measuring reaction force to the trocar support

被引:1
|
作者
Kim S. [1 ]
Kim C. [1 ]
Lee D.Y. [1 ]
机构
[1] Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology
关键词
Force estimation; Haptics; Surgical robot;
D O I
10.5302/J.ICROS.2016.16.0114
中图分类号
学科分类号
摘要
This paper proposes a method to estimate vertical interaction force to the end of the surgical instrument by measuring reaction force at the part supporting the trocar. Relation between the force to the trocar and the interaction force is derived using the beam theory. The vertical interaction force is modeled as a function of the reaction force to the trocar and the distance between the drape plate and the trocar. Experimental results show that error is induced by the asymmetric shape of the trocar tip because contact position between the instrument and the trocar tip is changed depending on the direction of the interaction force. The theoretical relation, therefore, is compensated and reduced. Average L2 relative error of the estimated force in the x-direction and the y-direction is 5.81 % and 5.99 %, respectively. © ICROS 2016.
引用
收藏
页码:615 / 618
页数:3
相关论文
共 50 条
  • [21] USE OF A FORCE MEASURING INSTRUMENT DURING CERVICAL DILATATION
    FISHER, J
    ANTHONY, GS
    MCMANUS, TJ
    COUTTS, JRT
    CALDER, AA
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1981, 5 (04) : 194 - 195
  • [22] An Instrument for Measuring Force Vector and Frequency of CPR Compressions
    Ferreira, Lorran R.
    Kapps, Graziele W.
    de Oliveira, Jauvane C.
    Shirmohammadi, Shervin
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1510 - 1514
  • [23] Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
    Nahiyan, Md Helal An
    Mizuno, Takeshi
    Takasaki, Masaya
    Ishino, Yuji
    Hara, Masayuki
    Yamaguchi, Daisuke
    SENSORS, 2019, 19 (04)
  • [24] Validation of a New Measuring Instrument for the Assessment of Bite Force
    Nitschke, Ina
    Moede, Celine
    Hopfenmueller, Werner
    Sobotta, Bernhard A. J.
    Koenig, Andreas
    Jockusch, Julia
    DIAGNOSTICS, 2023, 13 (23)
  • [25] Measurement of force acting on surgical instrument for force-feedback to master robot console
    Shimachi, S
    Hakozaki, Y
    Tada, T
    Fujiwara, Y
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 538 - 546
  • [26] Needle-Tissue Interaction Force State Estimation for Robotic Surgical Suturing
    Jackson, Russell C.
    Desai, Viraj
    Castillo, Jean P.
    Cavusoglu, M. Cenk
    2016 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2016), 2016, : 3659 - 3664
  • [27] The vertical ground reaction force for analysis of balance?
    Önell, A
    GAIT & POSTURE, 2000, 12 (01) : 7 - 13
  • [28] Reaction Force Estimation of Electro-hydrostatic Actuator Using Reaction Force Observer
    Umeda, Kodai
    Sakuma, Tomoki
    Tsuda, Kenta
    Sakaino, Sho
    Tsuji, Toshiaki
    IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2018, 7 (03) : 250 - 258
  • [29] Controlling of Applied Force and Cornea Displacement Estimation in Robotic Corneal Surgery With a Gripper Surgical Instrument
    Abadi, Ali Soltani Sharif
    Ordys, Andrew
    Pierscionek, Barbara
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2025, 21 (01):
  • [30] Estimation of Molecular Interaction Force Using Atomic Force Microscopy for Bioapplication
    Tsai, Hweiyan
    Chen, Zihkai
    Deng, Huiwen
    Tsai, Sinmei
    Fuh, C. Bor
    JOURNAL OF PHYSICAL CHEMISTRY B, 2016, 120 (42): : 10932 - 10935