An Instrument for Measuring Force Vector and Frequency of CPR Compressions

被引:0
|
作者
Ferreira, Lorran R. [1 ]
Kapps, Graziele W. [1 ]
de Oliveira, Jauvane C. [1 ]
Shirmohammadi, Shervin [2 ]
机构
[1] LNCC, Natl Lab Sci Comp, Appl Multimedia & Virtual Environm ABoVE Lab, Petropolis, RS, Brazil
[2] Univ Ottawa, Distributed & Collaborat Virtual Environm Res DIS, Ottawa, ON, Canada
关键词
cardiopulmonary resuscitation measurement; force measurement; medical training systems;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardio-Pulmonary Resuscitation (CPR) is a technique that allows a CPR certified person to keep alive someone whose heartbeat and/or breathing has stopped. Through compressions applied to the thorax of the individual in need of help, one can maintain the blood flow and air intake until further help (and equipment) arrives. Training for CPR is performed using manikins that mimic a human torso. In this paper, we design an instrument for measuring the force vector (magnitude and direction) and frequency of CPR compressions applied during CPR training sessions, to help a trainer objectively evaluate the performance of trainees. Excessive/insufficient force or frequency of compressions will harm, not help, the person in need. So it is important for a trainer to measure these parameters. Our instrument uses the standard CPR manikin plus a Nintendo Wii Fit balance board, and is therefore practical and affordable. Our experiments conducted with real subjects show that our system can measure these parameters with a standard uncertainty of 1.96 N, 0.79 degrees, and 0.26 Hz, respectively for force, direction and frequency.
引用
收藏
页码:1510 / 1514
页数:5
相关论文
共 50 条
  • [1] A 3D-Printable Instrument to Improve Force Vector Measurement in CPR Training
    Silva-Calpa, Greis F. M.
    Teixeira, Carina C.
    Marx, Felipe C.
    de Oliveira, Jauvane C.
    Shirmohammadi, Shervin
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2018, 21 (01) : 25 - +
  • [2] An Alternative to Derive the Instantaneous Frequency of the Chest Compressions to Suppress the CPR Artifact
    Ayala, U.
    Aramendi, E.
    Irusta, U.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 545 - 548
  • [3] Effects of rescuer position on the kinematics of cardiopulmonary resuscitation (CPR) and the force of delivered compressions
    Chi, Chih-Hsien
    Tsou, Jui-Yi
    Su, Fong-Chin
    RESUSCITATION, 2008, 76 (01) : 69 - 75
  • [4] CONTACTLESS INSTRUMENT FOR MEASURING MOMENT OF FORCE
    SULIMOV, YI
    LITVINOV, YG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (06) : 1664 - 1664
  • [5] Technique for chest compressions in adult CPR
    Rajab, Taufiek K.
    Pozner, Charles N.
    Conrad, Claudius
    Cohn, Lawrence H.
    Schmitto, Jan D.
    WORLD JOURNAL OF EMERGENCY SURGERY, 2011, 6
  • [6] Technique for chest compressions in adult CPR
    Taufiek K Rajab
    Charles N Pozner
    Claudius Conrad
    Lawrence H Cohn
    Jan D Schmitto
    World Journal of Emergency Surgery, 6
  • [7] Pauses in compressions during pediatric CPR: Opportunities for improving CPR quality
    O'Connell, Karen J.
    Keane, Ryan R.
    Cochrane, Niall H.
    Sandler, Alexis B.
    Donoghue, Aaron J.
    Kerrey, Benjamin T.
    Myers, Sage R.
    Vazifedan, Turaj
    Mullan, Paul C.
    RESUSCITATION, 2019, 145 : 158 - 165
  • [8] AN INSTRUMENT FOR MEASURING VECTOR MAGNETIZATION AT HIGH TEMPERATURES
    WILSON, RL
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1962, 7 (01): : 125 - &
  • [9] TRIGGERING ANGLE AND FREQUENCY MEASURING INSTRUMENT
    ILANGO, B
    RAMAMURTHI, VP
    PERINBAM, RP
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS AND CONTROL INSTRUMENTATION, 1978, 25 (02): : 173 - 174
  • [10] INSTRUMENT FOR MEASURING SMALL FREQUENCY FLUCTUATIONS
    VORONIN, AV
    GONCHAROV, SE
    KUZNETSOV, VM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (06) : 1341 - 1342