An Instrument for Measuring Force Vector and Frequency of CPR Compressions

被引:0
|
作者
Ferreira, Lorran R. [1 ]
Kapps, Graziele W. [1 ]
de Oliveira, Jauvane C. [1 ]
Shirmohammadi, Shervin [2 ]
机构
[1] LNCC, Natl Lab Sci Comp, Appl Multimedia & Virtual Environm ABoVE Lab, Petropolis, RS, Brazil
[2] Univ Ottawa, Distributed & Collaborat Virtual Environm Res DIS, Ottawa, ON, Canada
关键词
cardiopulmonary resuscitation measurement; force measurement; medical training systems;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardio-Pulmonary Resuscitation (CPR) is a technique that allows a CPR certified person to keep alive someone whose heartbeat and/or breathing has stopped. Through compressions applied to the thorax of the individual in need of help, one can maintain the blood flow and air intake until further help (and equipment) arrives. Training for CPR is performed using manikins that mimic a human torso. In this paper, we design an instrument for measuring the force vector (magnitude and direction) and frequency of CPR compressions applied during CPR training sessions, to help a trainer objectively evaluate the performance of trainees. Excessive/insufficient force or frequency of compressions will harm, not help, the person in need. So it is important for a trainer to measure these parameters. Our instrument uses the standard CPR manikin plus a Nintendo Wii Fit balance board, and is therefore practical and affordable. Our experiments conducted with real subjects show that our system can measure these parameters with a standard uncertainty of 1.96 N, 0.79 degrees, and 0.26 Hz, respectively for force, direction and frequency.
引用
收藏
页码:1510 / 1514
页数:5
相关论文
共 50 条
  • [41] SEMICONDUCTOR HIGH FREQUENCY INSTRUMENT OF MEASURING ELECTRICAL CONDUCTIVITY AND TITRATION
    GRANITSKAYA, LA
    LOPATIN, BA
    INDUSTRIAL LABORATORY, 1963, 29 (09): : 1250 - 1252
  • [42] CPR WITH INTERPOSED ABDOMINAL COMPRESSIONS IN DOGS - A SIMPLE TECHNIQUE TO AUGMENT PERFUSION
    VOORHEES, WD
    RALSTON, SH
    BABBS, CF
    CRITICAL CARE MEDICINE, 1983, 11 (03) : 226 - 226
  • [43] Longer Pauses Between CPR Compressions and Defibrillation May Decrease Survival
    Mitka, Mike
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2011, 306 (08): : 813 - 814
  • [44] Standard versus continuous compressions CPR: Does fatigue play a role?
    Heidenreich, JW
    Higdon, TA
    Sanders, AB
    Berg, RA
    Kern, KB
    Ewy, GA
    ANNALS OF EMERGENCY MEDICINE, 2005, 46 (03) : S76 - S76
  • [45] Automatic detection of chest compressions for the assessment of CPR-quality parameters
    Ayala, U.
    Eftestol, T.
    Alonso, E.
    Irusta, U.
    Aramendi, E.
    Wali, S.
    Kramer-Johansen, J.
    RESUSCITATION, 2014, 85 (07) : 957 - 963
  • [46] A simulation trial of traditional dispatcher-assisted CPR versus compressions - Only dispatcher-assisted CPR
    Williams, Jefferson G.
    Brice, Jane H.
    De Maio, Valerie J.
    Jalbuena, Tracy
    PREHOSPITAL EMERGENCY CARE, 2006, 10 (02) : 247 - 253
  • [47] INVESTIGATIONS ON A NEW FORCE-FREQUENCY MEASURING GAUGE
    GRANTCHAROV, K
    BORISSOV, M
    DETCHEV, D
    SPASSOV, L
    YOSSIFOV, E
    ELECTRONICS LETTERS, 1980, 16 (02) : 71 - 72
  • [48] INSTRUMENT FOR MEASURING THE ELECTRIC-FIELD VECTOR OF HIGH-VOLTAGE EQUIPMENT
    KLIMASHEVSKII, IP
    KONDRATEV, BL
    POLETAEV, VA
    YURKEVICH, VM
    MEASUREMENT TECHNIQUES USSR, 1983, 26 (01): : 49 - 50
  • [49] Changing EMS dispatcher CPR instructions to 400 compressions before mouth-to-mouth improved bystander CPR rates
    Bray, Janet E.
    Deasy, Conor
    Walsh, Jamie
    Bacon, Andrew
    Currell, Alex
    Smith, Karen
    RESUSCITATION, 2011, 82 (11) : 1393 - 1398
  • [50] VISUAL Q-CPR®,PRFEEDBCK DURING CPR BY EXPERTENITD ICU NURSES INCREASES CONSISTENCY OF RATE OF CHEST COMPRESSIONS
    Icke, E. A.
    Gelissen, H. P. M. M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S230 - S230