Validation of a New Measuring Instrument for the Assessment of Bite Force

被引:0
|
作者
Nitschke, Ina [1 ,2 ]
Moede, Celine [1 ]
Hopfenmueller, Werner [3 ,4 ,5 ]
Sobotta, Bernhard A. J. [1 ]
Koenig, Andreas [6 ]
Jockusch, Julia [1 ,7 ]
机构
[1] Univ Leipzig, Dept Prosthet Dent & Mat Sci, Gerodontol Sect, Liebigstr 12, D-04103 Leipzig, Germany
[2] Univ Zurich, Ctr Dent Med, Clin Gen Special Care & Geriatr Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
[3] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, D-10117 Berlin, Germany
[4] Free Univ Berlin, Humboldt Univ Berlin, D-10117 Berlin, Germany
[5] Berlin Inst Hlth, D-10117 Berlin, Germany
[6] Univ Leipzig, Dept Prosthet Dent & Mat Sci, Mat Sci Sect, Liebigstr 12, D-04103 Leipzig, Germany
[7] Univ Zurich, Univ Res Prior Program Dynam Hlth Aging, CH-8050 Zurich, Switzerland
关键词
occlusal force; measuring device; prototype; measurement accuracy; chewing function; MASTICATORY PERFORMANCE; OCCLUSAL FORCE; QUANTITATIVE-EVALUATION; CHEWING EFFICIENCY; ABILITY; MUSCLE; SIZE; OVERDENTURES; ASSOCIATION; DENTURES;
D O I
10.3390/diagnostics13233498
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: this study aims to validate two occlusal-force-measuring devices by comparing them to a universal testing machine and assessing their reliability across various dental and prosthetic groups. The research comprised two parts: part 1 assessed the measurement accuracy of the Occlusal Force Meter GM 10 (R) (OFM) (Morita, Nagano Keiki, Higashimagome, Ohta-ku, Tokyo, Japan) and a prototype (PRO) by comparing them to a calibrated universal testing machine (ZWICK). Part 2 involved analyzing the devices' reliability based on clinical bite force measurements from study participants. Results: both devices become more accurate and reliable compared to the ZWICK over time of usage. Additionally, higher deviation from the ZWICK can be observed for higher values of forces applied and vice versa for both devices. The PRO's intraoral alignment influences its mean values compared to the OFM in different dental and prosthetic groups. Conclusion: both devices had limitations and required quadratic function calibration, making them suitable only for progression measurements. The study concludes that both the OFM and PRO devices can measure occlusal forces with improved accuracy over time. Intraoral alignment should be considered. Their easy-to-use clinical application would allow a more widespread use of masticatory function diagnosis, which could indicate the need for treatment and improve treatment planning.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] A validation study of a new instrument for low cost bite force measurement
    Testa, Marco
    Di Marco, Anna
    Pertusio, Raffaele
    Van Roy, Peter
    Cattrysse, Erik
    Roatta, Silvestro
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2016, 30 : 243 - 248
  • [2] The Reliability of a New Device for Measuring the Maximum Bite Force
    Patil, Santosh R.
    Maragathavalli, G.
    Ramesh, D. N. S. V.
    Naidu, Giridhar S.
    Alam, Mohammad Khursheed
    AlZoubi, Ibrahim A.
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [3] Laboratory Validation of a Novel Indigenously Developed Bite Force Measuring Device
    Ranjan, Madhu
    Kumar, Surender
    Singh, Bishnupati
    Mahuli, Amit, V
    Jha, Awanindra K.
    Naik, Shantala R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [4] Reproducibility assessment of an instrument for measuring the axial force of the tongue
    de Araujo, Taynara Gomes
    Rodrigues, Thalyla Magalhaes
    Moreira Moraes Furlan, Renata Maria
    de Las Casas, Estevam Barbosa
    Motta, Andrea Rodrigues
    CODAS, 2018, 30 (03):
  • [5] VALIDATION OF A MORALE MEASURING INSTRUMENT
    SMITH, KR
    JOURNAL OF EDUCATIONAL ADMINISTRATION, 1971, 9 (01): : 32 - 37
  • [6] Validation of a new instrument for measuring organisational supports for innovation: The OSIQ
    Pirola-Merlo, A
    Mann, L
    AUSTRALIAN JOURNAL OF PSYCHOLOGY, 2003, 55 : 141 - 141
  • [7] Validation and optimization of a new instrument for measuring the performances of ultrafiltration membranes
    Guo, Linyuan
    Rong, Yan
    Dai, Qiang
    Li, Jingmiao
    Feng, Shichun
    Jin, Dong
    WATER SUPPLY, 2022, 22 (01) : 474 - 480
  • [8] GNATHODYNAMOMETER DESIGNED FOR MEASURING TOTAL BITE FORCE
    WALSH, E
    GIBBS, C
    HIGGINS, A
    HOLBROOK, W
    JOURNAL OF DENTAL RESEARCH, 1980, 59 : 318 - 318
  • [9] Edible Bite Force Sensor: A Novel Approach to Measuring Bite Force in Biomedical and Dental Applications
    Milic, Lazar
    Kojic, Sanja
    Qureshi, Saima
    Simic, Mitar
    Duval, Raphael Georges
    Petrovic, Bojan
    Stojanovic, Goran M.
    MEDICAL SCIENCE MONITOR, 2024, 30 : e944050
  • [10] CONTACTLESS INSTRUMENT FOR MEASURING MOMENT OF FORCE
    SULIMOV, YI
    LITVINOV, YG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (06) : 1664 - 1664