T1 quantification with inversion recovery TrueFISP

被引:0
|
作者
机构
[1] Scheffler, Klaus
[2] Hennig, Jrgen
来源
Scheffler, K. (ksch@ukl.uni-freiburg.de) | 1600年 / John Wiley and Sons Inc.卷 / 45期
关键词
Systematic errors - Magnetization;
D O I
暂无
中图分类号
O441.2 [磁学]; TM12 [];
学科分类号
摘要
A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T1 estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T1 measurements was examined. Experiments were performed on different Gd-doped water phantoms and on humans. T1 values derived from inversion recovery TrueFISP were in excellent agreement with the single-point method even for flip angles up to 50. In terms of T1 accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. © 2001 Wiley-Liss, Inc.
引用
收藏
相关论文
共 50 条
  • [1] T1 quantification with inversion recovery TrueFISP
    Scheffler, K
    Hennig, J
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 720 - 723
  • [2] Inversion recovery TrueFISP:: Quantification of T1, T2, and spin density
    Schmitt, P
    Griswold, MA
    Jakob, PM
    Kotas, M
    Gulani, V
    Flentje, M
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 661 - 667
  • [3] Inversion recovery TrueFISP:: Quantification of T1, T2 and spin density (vol 51, pg 661, 2004)
    Schmitt, P
    Griswold, MA
    Jakob, PM
    Kotas, M
    Gulani, V
    Flentje, M
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 698 - 698
  • [4] SUPERFAST T1 DETERMINATION BY INVERSION RECOVERY
    CANET, D
    BRONDEAU, J
    ELBAYED, K
    JOURNAL OF MAGNETIC RESONANCE, 1988, 77 (03): : 483 - 490
  • [5] Rapid T1 quantification based on 3D phase sensitive inversion recovery
    Warntjes M.J.B.
    Kihlberg J.
    Engvall J.
    BMC Medical Imaging, 10 (1)
  • [6] Modified cine inversion recovery pulse sequence for the quantification of myocardial T1 and gadolinium partition coefficient
    Milanesi, Matteo
    Barison, Andrea
    Positano, Vincenzo
    Masci, Pier Giorgio
    De Marchi, Daniele
    Marinelli, Luca
    Hardy, Christopher J.
    Foo, Thomas K.
    Landini, Luigi
    Lombardi, Massimo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) : 109 - 118
  • [7] Saturation-inversion-recovery: A method for T1 measurement
    Wang, Hongzhi
    Zhao, Ming
    Ackerman, Jerome L.
    Song, Yiqiao
    JOURNAL OF MAGNETIC RESONANCE, 2017, 274 : 137 - 143
  • [8] THE DESIGN OF A MULTIPLE INVERSION RECOVERY SEQUENCE FOR T1 MEASUREMENT
    YOUNG, IR
    HALL, AS
    BYDDER, GM
    MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (02) : 99 - 108
  • [9] Optimized double inversion recovery for reduction of T1 weighting in fluid-attenuated inversion recovery
    Madhuranthakam, Ananth J.
    Sarkar, Subhendra N.
    Busse, Reed F.
    Bakshi, Rohit
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 81 - 88
  • [10] Inversion Recovery at 7 T in the Human Myocardium: Measurement of T1, Inversion Efficiency and B1+
    Rodgers, Christopher T.
    Piechnik, Stefan K.
    DelaBarre, Lance J.
    Van de Moortele, Pierre-Francois
    Snyder, Carl J.
    Neubauer, Stefan
    Robson, Matthew D.
    Vaughan, J. Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 1038 - 1046