Comparison of biomechanical effects of polyetheretherketone (PEEK) rods and titanium rods in lumbar long-segment instrumentation: a finite element study

被引:3
|
作者
Li, Chao [1 ]
Zhao, Yao [1 ]
Qi, Longtao [1 ]
Xu, Beiyu [1 ]
Yue, Lei [1 ]
Zhu, Ranlyu [1 ]
Li, Chunde [1 ]
机构
[1] Peking Univ First Hosp, Dept Orthoped, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
lumbar degenerative disease; posterior lumbar instrumentation; PEEK; dynamic stabilization; adjacent segment degeneration; finite element analysis; PEDICLE SCREW FIXATION; INTERBODY FUSION; SPINE; ADJACENT; STABILIZATION; STIFFNESS; STRESS;
D O I
10.3389/fbioe.2024.1416046
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction Polyetheretherketone (PEEK) lumbar fusion rods have been successfully used in short-segment posterior instrumentation to prevent adjacent segment degeneration. However, limited studies have reported their application in lumbar long-segment instrumentation. This study aimed to compare the biomechanical performances of PEEK rods and titanium rods in lumbar long-segment instrumentation using finite element (FE) models, with the expectation of providing clinical guidance.Methods A lumbar FE model (A) and four lumbar fixation FE models (BI, CI, BII, CII) of the L1-S1 vertebral body were developed using CT image segmentation (A: intact model; BI: intact model with L2-S1 PEEK rod internal fixation; CI: intact model with L2-S1 titanium rod internal fixation; BII: intact model with L3-S1 PEEK rod internal fixation; CII: intact model with L3-S1 titanium rod internal fixation). A 150-N preload was applied to the top surface of L1, similar to the intact model. The stresses on the lumbar intervertebral disc, facet joint, pedicle screws, and rods were calculated to evaluate the biomechanical effect of the different fixation procedures in lumbar long-segment instrumented surgery.Results Under the four physiological motion states, the average stresses on the adjacent segment intervertebral disc and facet joint in all fixation models were greater than those in the intact model. Furthermore, the average stresses on the adjacent segment intervertebral disc and facet joint were greater in models CI and CII than in models BI and BII, respectively. The average stresses on the pedicle screws and rods were decreased in models BI and BII compared with models CI and CII under the four physiological motion states, respectively.Discussion The PEEK rod internal fixation system may have better biomechanical properties than the titanium rod internal fixation system in delaying adjacent segment degeneration, improving the lumbar function of postoperative patients, and reducing the risk of screw loosening and breakage in lumbar long-segment instrumentation.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis
    Li, Jie
    Cao, Shuai
    Zhao, Bo
    BMC SURGERY, 2024, 24 (01)
  • [2] Biomechanical Analysis of a Long-Segment Fusion in a Lumbar Spine-A Finite Element Model Study
    Natarajan, Raghu N.
    Watanabe, Kei
    Hasegawa, Kazuhiro
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (09):
  • [3] Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
    Wenhao Li
    He Zhao
    Chuanhong Li
    Tao Liu
    Jianbin Guan
    Yongdong Yang
    Xing Yu
    Journal of Orthopaedic Surgery and Research, 18
  • [4] Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
    Li, Wenhao
    Zhao, He
    Li, Chuanhong
    Liu, Tao
    Guan, Jianbin
    Yang, Yongdong
    Yu, Xing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [5] Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review
    Li, Chan
    Liu, Lei
    Shi, Jian-Yong
    Yan, Kai-Zhong
    Shen, Wei-Zhong
    Yang, Zhen-Rong
    NEUROSURGICAL REVIEW, 2018, 41 (02) : 375 - 389
  • [6] Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review
    Chan Li
    Lei Liu
    Jian-Yong Shi
    Kai-Zhong Yan
    Wei-Zhong Shen
    Zhen-Rong Yang
    Neurosurgical Review, 2018, 41 : 375 - 389
  • [7] Nitinol Memory Rods Versus Titanium Rods: A Biomechanical Comparison of Posterior Spinal Instrumentation in a Synthetic Corpectomy Model
    Massey, Patrick A.
    Hoge, Stephen
    Nelson, Bradley G.
    Ogden, Alan L.
    Mody, Milan G.
    Myers, Mitchell
    Bilderback, Karl
    Solitro, Giovanni
    Barton, Richard S.
    GLOBAL SPINE JOURNAL, 2021, 11 (03) : 277 - 282
  • [8] Spinal motion and intradiscal pressure measurements before and after lumbar spine instrumentation with titanium or PEEK rods
    Abode-Iyamah, Kingsley
    Kim, Sam Byeong
    Grosland, Nicole
    Kumar, Rajinder
    Belirgen, Muhittin
    Lim, Tae Hong
    Torner, James
    Hitchon, Patrick W.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (04) : 651 - 655
  • [9] Biomechanical comparison of four types of instrumentation constructs for revision surgery in lumbar adjacent segment disease: A finite element study
    Tan, Quan-chang
    Liu, Zi-xuan
    Zhao, Yan
    Huang, Xin-yi
    Bai, Hao
    Yang, Zhao
    Zhao, Xiong
    Du, Cheng-fei
    Lei, Wei
    Wu, Zi-xiang
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 134
  • [10] Biomechanical Study of Long-Segment Spine Instrumentation: The Effect of Cross-Links
    Wang, Tianhao
    Li, Chenming
    Wang, Yan
    MAN-MACHINE-ENVIRONMENT SYSTEM ENGINEERING (MMESE 2019), 2020, 576 : 103 - 111