Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis

被引:7
|
作者
Li, Wenhao [1 ,2 ]
Zhao, He [2 ]
Li, Chuanhong [1 ,2 ]
Liu, Tao [1 ,2 ]
Guan, Jianbin [1 ,2 ]
Yang, Yongdong [1 ,2 ]
Yu, Xing [2 ]
机构
[1] Beijing Univ Chinese Med, Beijing 100700, Peoples R China
[2] Beijing Univ Chinese Med, Dongzhimen Hosp, Beijing 100700, Peoples R China
关键词
Lumbar fusion surgery; Meta-analysis; PEEK rod; Titanium rod; SPINE; IMPLANT;
D O I
10.1186/s13018-023-03817-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Rigid fixation, represented by titanium rods, is a widely used fixation technique for lumbar fusion. However, this technique carries the risk of degeneration of adjacent segments. In recent years, the semi-rigid fixation technique represented by PEEK rods has gradually matured, and its effectiveness has been verified by numerous studies. The aim of this study was to systematically evaluate the effectiveness of these two fixation modalities in posterior lumbar fusion surgery. Methods Studies meeting the inclusion criteria were searched in PubMed, Cochrane Library, ScienceDirect, Embase, CNKI, and Wanfang databases. After data extraction and quality assessment of included studies, meta-analysis was performed using STATA 15.1 software. The protocol for this systematic review was registered on INPLASY (2021110049) and is available in full on the inplasy.com (https://inplasy.com/inplasy-2021-11-0049/). Results Fifteen relevant studies were finally included, including eight prospective studies and seven retrospective studies. The results of meta-analysis showed that in ODI (P = 0.000), JOA score (P = 0.017), VAS score for lower limb pain (P = 0.027), fusion rate of bone graft at week 12 (P = 0.001), fusion rate of bone graft at last follow-up (P = 0.028), there was a statistical difference between the two groups. The PEEK rod group was superior to the titanium rod group in the above aspects. While in VAS score for LBP (P = 0.396), there was no statistical difference between the two groups. Conclusion Both PEEK rods and titanium rods are effective fixation materials in lumbar fusion surgery. PEEK rods may be superior to titanium rods in improving postoperative function and improving bone graft fusion rates. However, given the limitations of this study, whether these conclusions are applicable needs further research.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
    Wenhao Li
    He Zhao
    Chuanhong Li
    Tao Liu
    Jianbin Guan
    Yongdong Yang
    Xing Yu
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Polyetheretherketone (PEEK) Rods for Lumbar Fusion: A Systematic Review and Meta-Analysis
    Selim, Abdulhafez
    Mercer, Sarah
    Tang, Feng
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (02): : 190 - 200
  • [3] Polyetheretherketone Versus Titanium Cages for Posterior Lumbar Interbody Fusion: Meta-Analysis and Review of the Literature
    Massaad, Elie
    Fatima, Nida
    Kiapour, Ali
    Hadzipasic, Muhamed
    Shankar, Ganesh M.
    Shin, John H.
    NEUROSPINE, 2020, 17 (01) : 125 - +
  • [4] Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion: A preliminary report
    Qi, Lei
    Li, Mu
    Zhang, Shuai
    Xue, Jingsong
    Si, Haipeng
    ACTA NEUROCHIRURGICA, 2013, 155 (07) : 1187 - 1193
  • [5] Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion: A preliminary report
    Lei Qi
    Mu Li
    Shuai Zhang
    Jingsong Xue
    Haipeng Si
    Acta Neurochirurgica, 2013, 155 : 1187 - 1193
  • [6] Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review
    Li, Chan
    Liu, Lei
    Shi, Jian-Yong
    Yan, Kai-Zhong
    Shen, Wei-Zhong
    Yang, Zhen-Rong
    NEUROSURGICAL REVIEW, 2018, 41 (02) : 375 - 389
  • [7] Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review
    Chan Li
    Lei Liu
    Jian-Yong Shi
    Kai-Zhong Yan
    Wei-Zhong Shen
    Zhen-Rong Yang
    Neurosurgical Review, 2018, 41 : 375 - 389
  • [8] Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis
    Li, Jie
    Cao, Shuai
    Zhao, Bo
    BMC SURGERY, 2024, 24 (01)
  • [9] Posterior stabilization with polyetheretherketone (PEEK) rods and transforaminal lumbar interbody fusion (TLIF) with titanium rods for single-level lumbar spine degenerative disease in patients above 70 years of age
    Li, Edwin A.
    Kamenova, Maria
    Soleman, Jehuda
    Fiebig, Oliver
    Mehrkens, Arne
    Scharen, Stefan
    SWISS MEDICAL WEEKLY, 2023, 153 : 70S - 70S
  • [10] Posterior stabilization with polyetheretherketone (PEEK) rods and transforaminal lumbar interbody fusion (TLIF) with titanium rods for single-level lumbar spine degenerative disease in patients above 70 years of age
    Kamenova, M.
    Li, E.
    Soleman, J.
    Fiebig, O.
    Mehrkens, A.
    Schaeren, S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 2831 - 2843