Numerical simulation in magnetic resonance imaging radiofrequency dosimetry

被引:0
|
作者
Subaar, Christiana [1 ]
Gyan, Emmanuel [2 ]
Dompreh, Kwadwo A. [3 ]
Amoako, Joseph K. [4 ]
Edusei, George [5 ]
Owusu, Alfred [3 ]
机构
[1] Kwame Nkrumah Univ Sci & Technol, Dept Phys, Kumasi, Ghana
[2] Sunyani Tech Univ, Fac Appl Sci, Dept Pharmaceut Sci, Sunyani, Ghana
[3] Univ Cape Coast, Dept Phys, Cape Coast, Ghana
[4] Ghana Atom Energy Commiss GAEC, Radiat Protect Inst, Accra, Ghana
[5] Univ Environm & Sustainable Dev, Somanya, Ghana
来源
关键词
electromagnetic field; in-vivo; invasive; radiofrequency; temperature; ELECTROMAGNETIC-FIELDS; MR PROCEDURES; HUMAN HEAD; TEMPERATURE; EXPOSURE; BODY; MULTIREGION; ABSORPTION;
D O I
10.1088/2057-1976/ad6a68
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance Imaging (MRI) employs a radiofrequency electromagnetic field to create pictures on a computer. The prospective biological consequences of exposure to radiofrequency electromagnetic fields (RF EMFs) have not yet been demonstrated, and there is not enough evidence on biological hazards to offer a definite response concerning possible RF health dangers. Therefore, it is crucial to research the health concerns in reaction to RF EMFs, considering the entire exposure in terms of patients receiving MRI. Monitoring increases in temperature in-vivo throughout MRI scan is extremely invasive and has resulted in a rise in the utilization of computational methods to estimate distributions of temperatures. The purpose of this study is to estimate the absorbed power of the brain exposed to RF in patients undergoing brain MRI scan. A three-dimensional Penne's bio-heat equation was modified to computationally analyze the temperature distributions and potential thermal effects within the brain during MRI scans in the 0.3 T to 1.5 T range (12.77 MHz to 63.87 MHz). The instantaneous temperature distributions of the in-vivo tissue in the brain temperatures measured at a time, t = 20.62 s is 0.2 degrees C and t = 30.92 s is 0.4 degrees C, while the highest temperatures recorded at 1.03 min and 2.06 min were 0.4 degrees C and 0.6 degrees C accordingly. From the temperature distributions of the in-vivo tissue in the brain temperatures measured, there is heat build-up in patients who are exposed to electromagnetic frequency ranges, and, consequently, temperature increases within patients are difficult to prevent. The study has, however, indicated that lengthier imaging duration appears to be related to increasing body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] RADIOFREQUENCY COIL DESIGNS FOR NUCLEAR MAGNETIC-RESONANCE ZEUGMATOGRAPHIC IMAGING
    BERNARDO, ML
    COHEN, AJ
    LAUTERBUR, PC
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 372 : 277 - 284
  • [42] Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging
    Huettner, Andrew M.
    Mickevicius, Nikolai J.
    Ersoz, Ali
    Koch, Kevin M.
    Muftuler, L. Tugan
    Nencka, Andrew S.
    PLOS ONE, 2015, 10 (10):
  • [43] Radiofrequency microcoils in magnetic resonance
    Webb, Andrew G.
    Progress in nuclear magnetic resonance spectroscopy, 1997, 31 (01): : 1 - 42
  • [45] Numerical simulation of magnetic susceptibility effects in nuclear magnetic resonance spectroscopy
    Mayer, C
    Terheiden, A
    JOURNAL OF CHEMICAL PHYSICS, 2003, 118 (06): : 2775 - 2782
  • [46] System for automated magnetic resonance imaging of a superheated emulsion chamber for brachytherapy dosimetry
    Pratt, RG
    Schmithorst, VJ
    Lamba, M
    Dardzinski, BJ
    d'Errico, F
    Nath, R
    Holland, SK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (06): : 2417 - 2421
  • [47] Effect of subpixel magnetic resonance imaging shifts on radiosurgical dosimetry for vestibular schwannoma
    Borden, JA
    Tsai, JS
    Mahajan, A
    JOURNAL OF NEUROSURGERY, 2002, 97 : 445 - 449
  • [48] Polymer gel dosimetry by nuclear Overhauser enhancement (NOE) magnetic resonance imaging
    Quevedo, Ana
    Luo, Guozhen
    Galhardo, Edvaldo
    Price, Michael
    Nicolucci, Patricia
    Gore, John C.
    Zu, Zhongliang
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [49] Nuclear Overhauser Enhancement (NOE) Magnetic Resonance Imaging for Polymer Gel Dosimetry
    Quevedo, A.
    Lu, G.
    Price, M.
    Zu, Z.
    Nicolucci, P.
    Gore, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E613 - E613
  • [50] Characterization of a new polymer gel for radiosurgery dosimetry using Magnetic Resonance Imaging
    Petrokokkinos, L.
    Kozicki, M.
    Pantelis, E.
    Antypas, C.
    Fijuth, J.
    Karaiskos, P.
    Sakelliou, L.
    Seimenis, I.
    JOURNAL OF INSTRUMENTATION, 2009, 4