Numerical simulation in magnetic resonance imaging radiofrequency dosimetry

被引:0
|
作者
Subaar, Christiana [1 ]
Gyan, Emmanuel [2 ]
Dompreh, Kwadwo A. [3 ]
Amoako, Joseph K. [4 ]
Edusei, George [5 ]
Owusu, Alfred [3 ]
机构
[1] Kwame Nkrumah Univ Sci & Technol, Dept Phys, Kumasi, Ghana
[2] Sunyani Tech Univ, Fac Appl Sci, Dept Pharmaceut Sci, Sunyani, Ghana
[3] Univ Cape Coast, Dept Phys, Cape Coast, Ghana
[4] Ghana Atom Energy Commiss GAEC, Radiat Protect Inst, Accra, Ghana
[5] Univ Environm & Sustainable Dev, Somanya, Ghana
来源
关键词
electromagnetic field; in-vivo; invasive; radiofrequency; temperature; ELECTROMAGNETIC-FIELDS; MR PROCEDURES; HUMAN HEAD; TEMPERATURE; EXPOSURE; BODY; MULTIREGION; ABSORPTION;
D O I
10.1088/2057-1976/ad6a68
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance Imaging (MRI) employs a radiofrequency electromagnetic field to create pictures on a computer. The prospective biological consequences of exposure to radiofrequency electromagnetic fields (RF EMFs) have not yet been demonstrated, and there is not enough evidence on biological hazards to offer a definite response concerning possible RF health dangers. Therefore, it is crucial to research the health concerns in reaction to RF EMFs, considering the entire exposure in terms of patients receiving MRI. Monitoring increases in temperature in-vivo throughout MRI scan is extremely invasive and has resulted in a rise in the utilization of computational methods to estimate distributions of temperatures. The purpose of this study is to estimate the absorbed power of the brain exposed to RF in patients undergoing brain MRI scan. A three-dimensional Penne's bio-heat equation was modified to computationally analyze the temperature distributions and potential thermal effects within the brain during MRI scans in the 0.3 T to 1.5 T range (12.77 MHz to 63.87 MHz). The instantaneous temperature distributions of the in-vivo tissue in the brain temperatures measured at a time, t = 20.62 s is 0.2 degrees C and t = 30.92 s is 0.4 degrees C, while the highest temperatures recorded at 1.03 min and 2.06 min were 0.4 degrees C and 0.6 degrees C accordingly. From the temperature distributions of the in-vivo tissue in the brain temperatures measured, there is heat build-up in patients who are exposed to electromagnetic frequency ranges, and, consequently, temperature increases within patients are difficult to prevent. The study has, however, indicated that lengthier imaging duration appears to be related to increasing body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Assessment of Submucosal Radiofrequency Tonsil Reduction by Magnetic Resonance Imaging
    Back, Leif
    Tervahartiala, Pekka
    Piilonen, Anneli
    Makitie, Antti
    Ylikoski, Jukka
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2009, 38 (05): : 537 - 544
  • [22] VALIDATION OF NUMERICAL APPROACHES FOR ELECTROMAGNETIC CHARACTERIZATION OF MAGNETIC RESONANCE RADIOFREQUENCY COILS
    Stara, Riccardo
    Fontana, Nunzia
    Tiberi, Gianluigi
    Monorchio, Agostino
    Manara, Giuliano
    Alfonsetti, Maria
    Galante, Angelo
    Vitacolonna, Assunta
    Alecci, Marcello
    Retico, Alessandra
    Tosetti, Michela
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2013, 29 : 121 - 136
  • [23] Play simulation for children in magnetic resonance imaging
    Heales, Christine J.
    Lloyd, Ellie
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (01) : 10 - 16
  • [24] ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators
    Jarrad Begg
    Urszula Jelen
    Zoe Moutrie
    Chris Oliver
    Lois Holloway
    Rhonda Brown
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1 - 17
  • [25] Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging
    Chung, AH
    Jolesz, FA
    Hynynen, K
    MEDICAL PHYSICS, 1999, 26 (09) : 2017 - 2026
  • [26] Simulation approaches for magnetic resonance imaging sensors
    Korvink, Jan G.
    Liu, Zhenyu
    Peter, Andreas
    Del Tin, Laura
    Jia, Feng
    Zohair, Raghad
    El-Kair, Ibrahim
    EUROSIME 2009: THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICRO-ELECTRONICS AND MICRO-SYSTEMS, 2009, : 25 - 32
  • [27] A new polymer gel for magnetic resonance imaging (MRI) radiation dosimetry
    Pappas, E
    Maris, T
    Angelopoulos, A
    Paparigopoulou, M
    Sakelliou, L
    Sandilos, P
    Voyiatzi, S
    Vlachos, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10): : 2677 - 2684
  • [28] Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
    Maryanski, MJ
    Ibbott, GS
    Eastman, P
    Schulz, RJ
    Gore, JC
    MEDICAL PHYSICS, 1996, 23 (05) : 699 - 705
  • [29] Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
    Department of Diagnostic Radiology, Yale University, School of Medicine, P.O. Box 208042, New Haven, CT 06520-8042, United States
    不详
    不详
    不详
    不详
    不详
    MED. PHYS., 5 (699-705):
  • [30] Magnetic resonance imaging of microbubbles in a superheated emulsion chamber for brachytherapy dosimetry
    Lamba, M
    Holland, SK
    Elson, H
    d'Errico, F
    Nath, R
    MEDICAL PHYSICS, 1998, 25 (12) : 2316 - 2325