Numerical simulation in magnetic resonance imaging radiofrequency dosimetry

被引:0
|
作者
Subaar, Christiana [1 ]
Gyan, Emmanuel [2 ]
Dompreh, Kwadwo A. [3 ]
Amoako, Joseph K. [4 ]
Edusei, George [5 ]
Owusu, Alfred [3 ]
机构
[1] Kwame Nkrumah Univ Sci & Technol, Dept Phys, Kumasi, Ghana
[2] Sunyani Tech Univ, Fac Appl Sci, Dept Pharmaceut Sci, Sunyani, Ghana
[3] Univ Cape Coast, Dept Phys, Cape Coast, Ghana
[4] Ghana Atom Energy Commiss GAEC, Radiat Protect Inst, Accra, Ghana
[5] Univ Environm & Sustainable Dev, Somanya, Ghana
来源
关键词
electromagnetic field; in-vivo; invasive; radiofrequency; temperature; ELECTROMAGNETIC-FIELDS; MR PROCEDURES; HUMAN HEAD; TEMPERATURE; EXPOSURE; BODY; MULTIREGION; ABSORPTION;
D O I
10.1088/2057-1976/ad6a68
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance Imaging (MRI) employs a radiofrequency electromagnetic field to create pictures on a computer. The prospective biological consequences of exposure to radiofrequency electromagnetic fields (RF EMFs) have not yet been demonstrated, and there is not enough evidence on biological hazards to offer a definite response concerning possible RF health dangers. Therefore, it is crucial to research the health concerns in reaction to RF EMFs, considering the entire exposure in terms of patients receiving MRI. Monitoring increases in temperature in-vivo throughout MRI scan is extremely invasive and has resulted in a rise in the utilization of computational methods to estimate distributions of temperatures. The purpose of this study is to estimate the absorbed power of the brain exposed to RF in patients undergoing brain MRI scan. A three-dimensional Penne's bio-heat equation was modified to computationally analyze the temperature distributions and potential thermal effects within the brain during MRI scans in the 0.3 T to 1.5 T range (12.77 MHz to 63.87 MHz). The instantaneous temperature distributions of the in-vivo tissue in the brain temperatures measured at a time, t = 20.62 s is 0.2 degrees C and t = 30.92 s is 0.4 degrees C, while the highest temperatures recorded at 1.03 min and 2.06 min were 0.4 degrees C and 0.6 degrees C accordingly. From the temperature distributions of the in-vivo tissue in the brain temperatures measured, there is heat build-up in patients who are exposed to electromagnetic frequency ranges, and, consequently, temperature increases within patients are difficult to prevent. The study has, however, indicated that lengthier imaging duration appears to be related to increasing body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators
    Begg, Jarrad
    Jelen, Urszula
    Moutrie, Zoe
    Oliver, Chris
    Holloway, Lois
    Brown, Rhonda
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 1 - 17
  • [32] Radiofrequency magnetic resonance coils and communication antennas: Simulation and design strategies
    Giovannetti, Giulio
    Tiberi, Gianluigi
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 1 - 7
  • [33] Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study
    Aubé, C
    Schmidt, D
    Brieger, J
    Schenk, M
    Helmberger, T
    Koenig, CW
    Schick, F
    Claussen, CD
    Pereira, PL
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (04) : 385 - 392
  • [34] Evaluation of ablation gaps between radiofrequency lesions with magnetic resonance imaging
    Dickfeld, T
    Kato, R
    Zviman, M
    Meininger, G
    Roguin, A
    Lardo, A
    Lickfett, L
    Berger, R
    Calkins, H
    Halperin, H
    CIRCULATION, 2003, 108 (17) : 655 - 655
  • [35] Magnetic resonance imaging characteristics of renal tumors after radiofrequency ablation
    Svatek, RS
    Sims, R
    Anderson, JK
    Abdel-Aziz, K
    Cadeddu, JA
    UROLOGY, 2006, 67 (03) : 508 - 512
  • [36] A Brief Review of Radiofrequency Coils for Cardiac Magnetic Resonance Imaging and Spectroscopy
    Giovannetti, Giulio
    Flori, Alessandra
    Positano, Vincenzo
    De Marchi, Daniele
    Menichetti, Luca
    Pingitore, Alessandro
    CURRENT MEDICAL IMAGING REVIEWS, 2018, 14 (05) : 695 - 703
  • [37] Improvement of magnetic resonance imaging using a wireless radiofrequency resonator array
    Akbar Alipour
    Alan C. Seifert
    Bradley N. Delman
    Philip M. Robson
    Raj Shrivastava
    Patrick R. Hof
    Gregor Adriany
    Zahi A. Fayad
    Priti Balchandani
    Scientific Reports, 11
  • [38] EARLY POSTOPERATIVE APPEARANCE OF RADIOFREQUENCY LESIONS ON MAGNETIC-RESONANCE-IMAGING
    DESALLES, AAF
    BREKHUS, SD
    DESOUZA, EC
    BEHNKE, EI
    FARAHANI, K
    ANZAI, Y
    LUFKIN, R
    NEUROSURGERY, 1995, 36 (05) : 932 - 936
  • [39] Improvement of magnetic resonance imaging using a wireless radiofrequency resonator array
    Alipour, Akbar
    Seifert, Alan C.
    Delman, Bradley N.
    Robson, Philip M.
    Shrivastava, Raj
    Hof, Patrick R.
    Adriany, Gregor
    Fayad, Zahi A.
    Balchandani, Priti
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [40] X-ray compatible radiofrequency coil for magnetic resonance imaging
    Rieke, V
    Ganguly, A
    Daniel, BL
    Scott, G
    Pauly, JM
    Fahrig, R
    Pelc, NJ
    Butts, K
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1409 - 1414