Development and study of ultrasonic pulse velocity measurement system using wave analysis and two-point detection approach

被引:0
|
作者
Piyush
Yadav, Sanjay [1 ,2 ]
Dubey, P. K. [1 ]
机构
[1] CSIR Natl Phys Lab, Pressure Vacuum & Ultrason Metrol, Dr K S Krishnan Marg, New Delhi 110012, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 08期
关键词
Digital electronic circuits; Data acquisition circuits; Analogue electronic circuits; Data acquisition concepts;
D O I
10.1088/1748-0221/19/08/P08019
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article focuses on the development and analysis of an Ultrasonic Pulse Velocity (UPV) measurement system used for the evaluation of concrete and Reinforced Cement Concrete (RCC) in civil construction. The UPV tester is essential for on-site assessments of structures, as it is used to measure the velocity of ultrasonic waves within the material, directly correlating with its strength. UPV testing is affected by the attenuation of ultrasonic waves in concrete, particularly due to the interfacial transition zone. Excess ultrasonic attenuation results in the reduction in the received signal amplitude which may also results in the omission of the initial pulses due to threshold comparison at the receiver. The study highlights the impact of receiver gain on threshold error and discusses the limitations associated with ADC sampling rate and amplitude resolution. UPV measurement, including counter or data acquisition approach, have error contributions associated with threshold voltage comparison. The error due to threshold amplitude selection is quantified, emphasizing the importance of accurate signal analysis, particularly in highly attenuating medium. The article presents the design and development of a PC-based UPV tester with automatic threshold error compensation. The system includes a transmitter, receiver, 32-bit microcontroller, and a Graphical User Interface (GUI) for data analysis. The article introduces a two-point linear detection logic to minimize errors caused by selected signal amplitude and omission of initial pulses in transit time measurements. The proposed method provides effective resolution of 10 ns through software, even at low sampling rate of 2 MS/s. The experimental results demonstrate the effectiveness of the developed UPV tester, with comparisons to a reference calibration facility at CSIR-NPL. The standard deviation in the ultrasonic transit time measurement by the developed UPV device, with threshold error correction, was +/- 70 ns.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] VELOCITY-MEASUREMENT IN LIQUIDS BY USING REFLECTION TYPE ULTRASONIC CORRELATOR VIA WAVE NUMBER ANALYSIS IN MHZ RANGE
    IMANO, K
    SANNOMIYA, T
    CHUBACHI, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1988, 27 : 35 - 37
  • [42] Pulse wave velocity measurement along the ulnar artery in the wrist region using a high-frequency ultrasonic probe with H-topology
    Benchemoul, Maxime
    Mateo, Tony
    Savery, David
    Gehin, Claudine
    Massot, Bertrand
    Ferin, Guillaume
    Vince, Philippe
    Flesch, Martin
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [43] NONINVASIVE MEASUREMENT OF PULSE-WAVE VELOCITY USING TRANSPUTER-BASED ANALYSIS OF DOPPLER FLOW AUDIO SIGNALS
    STEWART, WR
    RAMSEY, MW
    JONES, CJH
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 (03) : 299 - 307
  • [44] Association between Brachial-Ankle Pulse Wave Velocity and Microalbuminuria and to Predict the Risk for the Development of Microalbuminuria Using Brachial-Ankle Pulse Wave Velocity Measurement in Type 2 Diabetes Mellitus Patients
    Kim, Byong-Kyu
    Acharya, Dilaram
    Nah, Deuk-Young
    Rhee, Moo-Yong
    Yoo, Seok-Ju
    Lee, Kwan
    HEALTHCARE, 2019, 7 (04)
  • [46] Fundamental study on ultrasonic measurement system to detect penetration of boulders using cepstrum analysis
    Kawamura, Y.
    Tsurushima, M.
    Ito, Y.
    Mizutani, K.
    Yamachika, S.
    Aoshima, N.
    Ha, E.
    ULTRASONICS, 2007, 46 (03) : 266 - 269
  • [47] Comparative study using video analysis and an ultrasonic measurement system to quantify mandibular movement
    Frisoli, M.
    Edelhoff, J. M.
    Gersdorff, N.
    Nicolet, J.
    Braidot, A.
    Engelke, W.
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2017, 35 (01): : 19 - 29
  • [48] Simultaneous measurement of the velocity of an ultrasonic shear wave and the thickness of a test object with plane-parallel boundaries using two antenna arrays
    Bazulin, E. G.
    Ismailov, G. M.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2013, 49 (08) : 446 - 457
  • [49] Simultaneous measurement of the velocity of an ultrasonic shear wave and the thickness of a test object with plane-parallel boundaries using two antenna arrays
    E. G. Bazulin
    G. M. Ismailov
    Russian Journal of Nondestructive Testing, 2013, 49 : 446 - 457
  • [50] A Bio-Impedance Measurement System for Portable Monitoring of Heart Rate and Pulse Wave Velocity Using Small Body Area
    Cho, Min-Chang
    Kim, Jee-Yeon
    Cho, SeongHwan
    ISCAS: 2009 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-5, 2009, : 3106 - 3109