Development and study of ultrasonic pulse velocity measurement system using wave analysis and two-point detection approach

被引:0
|
作者
Piyush
Yadav, Sanjay [1 ,2 ]
Dubey, P. K. [1 ]
机构
[1] CSIR Natl Phys Lab, Pressure Vacuum & Ultrason Metrol, Dr K S Krishnan Marg, New Delhi 110012, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 08期
关键词
Digital electronic circuits; Data acquisition circuits; Analogue electronic circuits; Data acquisition concepts;
D O I
10.1088/1748-0221/19/08/P08019
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article focuses on the development and analysis of an Ultrasonic Pulse Velocity (UPV) measurement system used for the evaluation of concrete and Reinforced Cement Concrete (RCC) in civil construction. The UPV tester is essential for on-site assessments of structures, as it is used to measure the velocity of ultrasonic waves within the material, directly correlating with its strength. UPV testing is affected by the attenuation of ultrasonic waves in concrete, particularly due to the interfacial transition zone. Excess ultrasonic attenuation results in the reduction in the received signal amplitude which may also results in the omission of the initial pulses due to threshold comparison at the receiver. The study highlights the impact of receiver gain on threshold error and discusses the limitations associated with ADC sampling rate and amplitude resolution. UPV measurement, including counter or data acquisition approach, have error contributions associated with threshold voltage comparison. The error due to threshold amplitude selection is quantified, emphasizing the importance of accurate signal analysis, particularly in highly attenuating medium. The article presents the design and development of a PC-based UPV tester with automatic threshold error compensation. The system includes a transmitter, receiver, 32-bit microcontroller, and a Graphical User Interface (GUI) for data analysis. The article introduces a two-point linear detection logic to minimize errors caused by selected signal amplitude and omission of initial pulses in transit time measurements. The proposed method provides effective resolution of 10 ns through software, even at low sampling rate of 2 MS/s. The experimental results demonstrate the effectiveness of the developed UPV tester, with comparisons to a reference calibration facility at CSIR-NPL. The standard deviation in the ultrasonic transit time measurement by the developed UPV device, with threshold error correction, was +/- 70 ns.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] On the development of coherent structure in a plane jet (Part 1, characteristics of two-point velocity correlation and analysis of eigenmodes by the KL expansion)
    Sakai, Y
    Tanaka, N
    Kushida, T
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2006, 49 (01) : 115 - 124
  • [32] Estimation of compressive strength of concrete structures using the ultrasonic pulse velocity method and spectral analysis of surface wave method
    Hong, S. U.
    Cho, Y. S.
    Kim, S. H.
    Lee, Y. T.
    MATERIALS RESEARCH INNOVATIONS, 2015, 19 : 1289 - 1294
  • [33] Development of a charge-carrier drift velocity measurement system in diamonds by using a UV pulse laser
    Fujita, F
    Homma, A
    Oshiki, Y
    Kaneko, JH
    Tsuji, K
    Meguro, K
    Yamamoto, Y
    Imai, T
    Teraji, T
    Sawamura, T
    Furusaka, M
    DIAMOND AND RELATED MATERIALS, 2005, 14 (11-12) : 1992 - 1994
  • [34] Initial Study on Pulse Wave Velocity Acquired from One Hand Using Two Synchronized Wireless Reflectance Pulse Oximeters
    Li, Kejia
    Warren, Steve
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6907 - 6910
  • [35] Validity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study
    Madireddy Umamaheshwar Rao Naidu
    Budda Muralidhar Reddy
    Sridhar Yashmaina
    Amar Narayana Patnaik
    Pingali Usha Rani
    BioMedical Engineering OnLine, 4
  • [36] Validity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study
    Naidu, Madireddy Umamaheshwar Rao
    Reddy, Budda Muralidhar
    Yashmaina, Sridhar
    Patnaik, Amar Narayana
    Rani, Pingali Usha
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [37] FUNDAMENTAL STUDY OF DEVELOPMENT OF FLOW VISUALIZATION SYSTEM USING ULTRASONIC VELOCITY PROFILER AND AUGMENTED REALITY
    Namiki, Yutaka
    Shoji, Naruki
    Kikura, Hiroshige
    PROCEEDINGS OF ASME 2024 FLUIDS ENGINEERING DIVISION SUMMER MEETING, VOL 2, FEDSM 2024, 2024,
  • [38] A learning-based image processing approach for pulse wave velocity estimation using spectrogram from peripheral pulse wave signals: An in silico study
    Vargas, Juan M.
    Bahloul, Mohamed A.
    Laleg-Kirati, Taous-Meriem
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [39] Wave Mode Discrimination of Coded Ultrasonic Guided Waves Using Two-Dimensional Compressed Pulse Analysis
    Malo, Sergio
    Fateri, Sina
    Livadas, Makis
    Mares, Cristinel
    Gan, Tat-Hean
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (07) : 1092 - 1101
  • [40] Ultrasonic position and velocity measurement for a moving object by M-sequence pulse compression using Doppler velocity estimation by spectrum-pattern analysis
    Ikari, Yohei
    Hirata, Shinnosuke
    Hachiya, Hiroyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (07)