Development and study of ultrasonic pulse velocity measurement system using wave analysis and two-point detection approach

被引:0
|
作者
Piyush
Yadav, Sanjay [1 ,2 ]
Dubey, P. K. [1 ]
机构
[1] CSIR Natl Phys Lab, Pressure Vacuum & Ultrason Metrol, Dr K S Krishnan Marg, New Delhi 110012, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 08期
关键词
Digital electronic circuits; Data acquisition circuits; Analogue electronic circuits; Data acquisition concepts;
D O I
10.1088/1748-0221/19/08/P08019
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article focuses on the development and analysis of an Ultrasonic Pulse Velocity (UPV) measurement system used for the evaluation of concrete and Reinforced Cement Concrete (RCC) in civil construction. The UPV tester is essential for on-site assessments of structures, as it is used to measure the velocity of ultrasonic waves within the material, directly correlating with its strength. UPV testing is affected by the attenuation of ultrasonic waves in concrete, particularly due to the interfacial transition zone. Excess ultrasonic attenuation results in the reduction in the received signal amplitude which may also results in the omission of the initial pulses due to threshold comparison at the receiver. The study highlights the impact of receiver gain on threshold error and discusses the limitations associated with ADC sampling rate and amplitude resolution. UPV measurement, including counter or data acquisition approach, have error contributions associated with threshold voltage comparison. The error due to threshold amplitude selection is quantified, emphasizing the importance of accurate signal analysis, particularly in highly attenuating medium. The article presents the design and development of a PC-based UPV tester with automatic threshold error compensation. The system includes a transmitter, receiver, 32-bit microcontroller, and a Graphical User Interface (GUI) for data analysis. The article introduces a two-point linear detection logic to minimize errors caused by selected signal amplitude and omission of initial pulses in transit time measurements. The proposed method provides effective resolution of 10 ns through software, even at low sampling rate of 2 MS/s. The experimental results demonstrate the effectiveness of the developed UPV tester, with comparisons to a reference calibration facility at CSIR-NPL. The standard deviation in the ultrasonic transit time measurement by the developed UPV device, with threshold error correction, was +/- 70 ns.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] DEVELOPMENT OF ULTRASONIC MEASUREMENT SYSTEM FOR SHAPE AND 2D VELOCITY FIELD USING ULTRASONIC VELOCITY PROFILER AND TOTAL FOCUSING METHODS
    Zhang, Zeliang
    Liu, Tianrun
    Batsaikhan, Munkhbat
    Takahashi, Hideharu
    Kikura, Hiroshige
    PROCEEDINGS OF 2021 28TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE28), VOL 4, 2021,
  • [22] Study on the development of the microstructure in cement-based materials by means of numerical simulation and ultrasonic pulse velocity measurement
    Ye, G
    Lura, P
    van Breugel, K
    Fraaij, ALA
    CEMENT & CONCRETE COMPOSITES, 2004, 26 (05): : 491 - 497
  • [23] Improved pressure contour analysis for estimating cardiac stroke volume using pulse wave velocity measurement
    Kamoi, Shun
    Pretty, Christopher
    Balmer, Joel
    Davidson, Shaun
    Pironet, Antoine
    Desaive, Thomas
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [24] Improved pressure contour analysis for estimating cardiac stroke volume using pulse wave velocity measurement
    Shun Kamoi
    Christopher Pretty
    Joel Balmer
    Shaun Davidson
    Antoine Pironet
    Thomas Desaive
    Geoffrey M. Shaw
    J. Geoffrey Chase
    BioMedical Engineering OnLine, 16
  • [25] Measurement of pulse wave velocity in children and young adults: a comparative study using three different devices
    Eva Kis
    Orsolya Cseprekál
    Andrea Kerti
    Paolo Salvi
    Athanase Benetos
    Andras Tisler
    Attila Szabó
    Tivadar Tulassay
    György S Reusz
    Hypertension Research, 2011, 34 : 1197 - 1202
  • [26] Noninvasive measurement of cardiac stroke volume using pulse wave velocity and aortic dimensions: a simulation study
    Charles F Babbs
    BioMedical Engineering OnLine, 13
  • [27] Measurement of pulse wave velocity in children and young adults: a comparative study using three different devices
    Kis, Eva
    Cseprekal, Orsolya
    Kerti, Andrea
    Salvi, Paolo
    Benetos, Athanase
    Tisler, Andras
    Szabo, Attila
    Tulassay, Tivadar
    Reusz, Gyoergy S.
    HYPERTENSION RESEARCH, 2011, 34 (11) : 1197 - 1202
  • [28] Noninvasive measurement of cardiac stroke volume using pulse wave velocity and aortic dimensions: a simulation study
    Babbs, Charles F.
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [29] Design and Parametric Analysis of a Wearable Dual-Photoplethysmograph Based System for Pulse Wave Velocity Detection
    Trujillo, Zachary
    Nathan, Viswam
    Cote, Gerard L.
    Jafari, Roozbeh
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017, : 2428 - 2431
  • [30] On the development of coherent structure in a plane jet: (Part 1, characteristics of two-point velocity correlation and analysis of Eigenmodes by the KL expansion)
    Department of Mechanical Science and Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
    JSME Int. J. Ser. B Fluids Therm. Eng., 1 (115-124):