Dose assessment in petrous bone CT: Effect of tube current modulation and scan length

被引:0
|
作者
Saga, Zouhir [1 ]
Rahmouni, Abdelaali [1 ]
Talbi, Mohammed [2 ]
Anam, Choirul [3 ]
Rezzouk, Abdellah [1 ]
机构
[1] Sidi Mohamed Ben Abdellah Univ, Fac Sci Dhar El Mahraz, Dept Phys, Lab Solid State Phys, Fes, Morocco
[2] Ibn Tofail Univ, Higher Inst Nursing Profess & Hlth Tech, Fac Sci, Rabat Dept Phys,Lab Mat & Subatom Phys, Kenitra, Morocco
[3] Diponegoro Univ, Fac Math & Sci, Dept Phys, Semarang, Indonesia
关键词
Petrous bone CT; TCM; Scan length; DLP; Effective dose;
D O I
10.1016/j.radphyschem.2024.112125
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this study is to compare the dosimetric performance of two CT acquisition protocols for the petrous bone: a standard fixed mAs protocol and a protocol using tube current modulation (TCM). By analyzing the scan length, dose-length product (DLP) and effective dose (ED) obtained with each protocol, we investigate whether TCM offers an advantage in terms of dose reduction while maintaining comparable image quality. To this end, 249 patients (women: 52%; men: 48%) were included in this study. The first center used TCM (120 kVp, 150 mA reference) for image acquisition, while the other centers opted for fixed mAs values. Acceptability of image quality was assessed using a standardized phantom (model 610 AAPM) by measuring noise uniformity and accuracy, contrast-to-noise ratio (CNR) and spatial resolution. The CTDIvol was not significantly different between center A and the other centers (p > 0.05), while DLP and ED were significantly different (p < 0.001), being reduced by a factor of 2 and 2.23 for scan length. We concluded that a scan with a 14.28% decrease in tube voltage from 140 kVp (136-170-210) mAs fixed to 120 kVp with TCM to 150 mA reference in helical scan mode can be recommended as an optimized protocol during CT examination of petrous bone while reducing DLP and ED to 50% without loss of diagnostic accuracy.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Dose reduction in body CT examinations by anatomically adapted tube current modulation
    Bautz, WA
    Heim, I
    Wolf, H
    Kalender, WA
    RADIOLOGY, 1997, 205 : 1399 - 1399
  • [32] Automatic tube current modulation for volume scan in a 320-detector row CT scanner
    Liao, Y. L.
    Lai, N. K.
    Tyan, Y. S.
    Chuang, K. S.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2013, 56 : 328 - 332
  • [33] Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom
    Merzan, Deborah
    Nowik, Patrik
    Poludniowski, Gavin
    Bujila, Robert
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1069):
  • [34] Scan Length Adjustment of CT Coronary Angiography Using the Calcium Scoring Scan: Effect on Radiation Dose
    Leschka, Sebastian
    Kim, Chan-Hi
    Baumueller, Stephan
    Stolzmann, Paul
    Scheffel, Hans
    Marincek, Borut
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) : W272 - W277
  • [35] Low-dose high-resolution CT of the petrous bone
    Husstedt, HW
    Prokop, M
    Dietrich, B
    Becker, H
    JOURNAL OF NEURORADIOLOGY, 2000, 27 (02) : 87 - 92
  • [36] Dose to Radiosensitive Organs During Routine Chest CT: Effects of Tube Current Modulation
    Angel, Erin
    Yaghmai, Nazanin
    Jude, Cecilia Matilda
    DeMarco, John J.
    Cagnon, Christopher H.
    Goldin, Jonathan G.
    McCollough, Cynthia H.
    Primak, Andrew N.
    Cody, Dianna D.
    Stevens, Donna M.
    McNitt-Gray, Michael F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : 1340 - 1345
  • [37] Real-Time Dose Measurements of Automatic Tube Current Modulation in Multislice CT
    Tsai, H. Y.
    Chang, Y. C.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [38] Prospective Optimization of CT under Tube Current Modulation: I. Organ Dose
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Samei, Ehsan
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [39] The Effect of Tube Current Modulation On Patient Dose and Image Quality in Patients Examined with Low-Dose Lung Cancer Screening CT
    Barreto, I.
    Verma, N.
    Carranza, C.
    Correa, N.
    Quails, N.
    Mohammed, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E691 - E691
  • [40] Overbeaming and overlapping of volume-scan CT with tube current modulation in a 320-detector row CT scanner
    Liao, Ying-Lan
    Chen, Yan-Shi
    Lai, Nan-Ku
    Chuang, Keh-Shih
    Tsai, Hui-Yu
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 225 - 229