Particle number size distribution evaluation of Plantower PMS5003 low-cost PM sensors - a field experiment

被引:0
|
作者
Caseiro, Alexandre [1 ]
Schmitz, Sean [1 ]
von Schneidemesser, Erika [1 ]
机构
[1] Res Inst Sustainabil Helmholtz Ctr Potsdam, Potsdam, Germany
来源
ENVIRONMENTAL SCIENCE-ATMOSPHERES | 2024年 / 4卷 / 10期
关键词
PARTICULATE MATTER SENSORS; AIR-QUALITY; ELECTROCHEMICAL SENSORS; LABORATORY EVALUATION; POLLUTION; PERFORMANCE; PURPLEAIR; PM2.5; CALIBRATION; NETWORKS;
D O I
10.1039/d4ea00086b
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of low-cost sensors (LCS) for the evaluation of the ambient pollution by particulate matter (PM) has grown and become significant for the scientific community in the past few years. However promising this novel technology is, the characterization of their limitations is still not satisfactory. Reports in the scientific literature rely on calibration, which implies the physical (or geographical) co-location of the LCS with reference in situ (or remote, e.g. onboard satellite platforms) instrumentation. However, calibration is not always feasible, and even when feasible, the validity of the developed relationship, even in similar settings, is subject to large uncertainties. In the present work, the performance of a popular LCS for PM, the Plantower PMS5003, is investigated. The LCS performs particle counts, which is the physical quantity that is input to the black-box model of the manufacturer to compute the ambient PM mass, which is output to the operator. The particle counts of LCS Plantower PMS5003 units were compared to those of the co-located research-grade Grimm EDM-164 monitor. The results show that humidity possibly has a reduced influence on the performance, but the performance can better be constrained, however spanning more than one order of magnitude in terms of agreement ratio, by functions of the actual particle count itself. In view of these results, further development in the field of LCS for PM monitoring should focus on improvements of the physical design of the devices, in order to enhance the sizing of the particles. The use of the actual Plantower PMS5003 models should be limited to the monitoring of PM mass in the smaller size bins. In terms of particle number distribution, the agreement ratio between a low-cost sensor and a research-grade instrument spans several orders of magnitude. The particle number can be constrained as a function of the reported particle number.
引用
收藏
页码:1183 / 1194
页数:12
相关论文
共 50 条
  • [21] A machine learning field calibration method for improving the performance of low-cost particle sensors
    Patra, Satya S.
    Ramsisaria, Rishabh
    Du, Ruihang
    Wu, Tianren
    Boor, Brandon E.
    Building and Environment, 2021, 190
  • [22] Field Evaluation of Low-Cost Particulate Matter Sensors for Measuring Wildfire Smoke
    Holder, Amara L.
    Mebust, Anna K.
    Maghran, Lauren A.
    McGown, Michael R.
    Stewart, Kathleen E.
    Vallano, Dena M.
    Elleman, Robert A.
    Baker, Kirk R.
    SENSORS, 2020, 20 (17) : 1 - 17
  • [23] Field Performance Evaluation of Low-Cost Soil Moisture Sensors in Irrigated Orchard
    Markovic, Monika
    Matosa Kocar, Maja
    Barac, Zeljko
    Turalija, Alka
    Atilgan, Atilgan
    Jug, Danijel
    Ravlic, Marija
    AGRICULTURE-BASEL, 2024, 14 (08):
  • [24] Influence of seasonal variation on spatial distribution of PM2.5 concentration using low-cost sensors
    Chaudhry, Sandeep Kumar
    Tripathi, Sachchida Nand
    Reddy, Tondapu Venkata Ramesh
    Kumar, Anil
    Madhwal, Sandeep
    Yadav, Amit Kumar
    Pradhan, Pranav Kumar
    Environmental Monitoring and Assessment, 2024, 196 (12)
  • [25] Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation
    Peck, Angela
    Handy, Rodney G.
    Sleeth, Darrah K.
    Schaefer, Camie
    Zhang, Yue
    Pahler, Leon F.
    Ramsay, Joemy
    Collingwood, Scott C.
    TOXICS, 2023, 11 (01)
  • [26] Field Evaluation and Calibration of Low-Cost Air Pollution Sensors for Environmental Exposure Research
    Huang, Jianwei
    Kwan, Mei-Po
    Cai, Jiannan
    Song, Wanying
    Yu, Changda
    Kan, Zihan
    Yim, Steve Hung-Lam
    SENSORS, 2022, 22 (06)
  • [27] Short-Term Field Evaluation of Low-Cost Sensors Operated by the "AirSensEUR" Platform
    Pichlhoefer, Alexander
    Korjenic, Azra
    ENERGIES, 2022, 15 (15)
  • [28] Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
    Feenstra, Brandon
    Papapostolou, Vasileios
    Hasheminassab, Sina
    Zhang, Hang
    Boghossian, Berj Der
    Cocker, David
    Polidori, Andrea
    ATMOSPHERIC ENVIRONMENT, 2019, 216
  • [29] Long-term Field Evaluation of Low-cost Particulate Matter Sensors in Nanjing
    Bai, Lu
    Huang, Lin
    Wang, Zhenglu
    Ying, Qi
    Zheng, Jun
    Shi, Xiaowen
    Hu, Jianlin
    AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (02) : 242 - 253