Particle number size distribution evaluation of Plantower PMS5003 low-cost PM sensors - a field experiment

被引:0
|
作者
Caseiro, Alexandre [1 ]
Schmitz, Sean [1 ]
von Schneidemesser, Erika [1 ]
机构
[1] Res Inst Sustainabil Helmholtz Ctr Potsdam, Potsdam, Germany
来源
ENVIRONMENTAL SCIENCE-ATMOSPHERES | 2024年 / 4卷 / 10期
关键词
PARTICULATE MATTER SENSORS; AIR-QUALITY; ELECTROCHEMICAL SENSORS; LABORATORY EVALUATION; POLLUTION; PERFORMANCE; PURPLEAIR; PM2.5; CALIBRATION; NETWORKS;
D O I
10.1039/d4ea00086b
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of low-cost sensors (LCS) for the evaluation of the ambient pollution by particulate matter (PM) has grown and become significant for the scientific community in the past few years. However promising this novel technology is, the characterization of their limitations is still not satisfactory. Reports in the scientific literature rely on calibration, which implies the physical (or geographical) co-location of the LCS with reference in situ (or remote, e.g. onboard satellite platforms) instrumentation. However, calibration is not always feasible, and even when feasible, the validity of the developed relationship, even in similar settings, is subject to large uncertainties. In the present work, the performance of a popular LCS for PM, the Plantower PMS5003, is investigated. The LCS performs particle counts, which is the physical quantity that is input to the black-box model of the manufacturer to compute the ambient PM mass, which is output to the operator. The particle counts of LCS Plantower PMS5003 units were compared to those of the co-located research-grade Grimm EDM-164 monitor. The results show that humidity possibly has a reduced influence on the performance, but the performance can better be constrained, however spanning more than one order of magnitude in terms of agreement ratio, by functions of the actual particle count itself. In view of these results, further development in the field of LCS for PM monitoring should focus on improvements of the physical design of the devices, in order to enhance the sizing of the particles. The use of the actual Plantower PMS5003 models should be limited to the monitoring of PM mass in the smaller size bins. In terms of particle number distribution, the agreement ratio between a low-cost sensor and a research-grade instrument spans several orders of magnitude. The particle number can be constrained as a function of the reported particle number.
引用
收藏
页码:1183 / 1194
页数:12
相关论文
共 50 条
  • [31] Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
    Rueda, Emilio Molina
    Carter, Ellison
    L'Orange, Christian
    Quinn, Casey
    Volckens, John
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2023, 10 (03) : 247 - 253
  • [32] Field evaluation of low-cost particulate matter sensors in high-and low-concentration environments
    Zheng, Tongshu
    Bergin, Michael H.
    Johnson, Karoline K.
    Tripathi, Sachchida N.
    Shirodkar, Shilpa
    Landis, Matthew S.
    Sutaria, Ronak
    Carlson, David E.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (08) : 4823 - 4846
  • [33] Seasonal Field Calibration of Low-Cost PM2.5 Sensors in Different Locations with Different Sources in Thailand
    Dejchanchaiwong, Racha
    Tekasakul, Perapong
    Saejio, Apichat
    Limna, Thanathip
    Le, Thi-Cuc
    Tsai, Chuen-Jinn
    Lin, Guan-Yu
    Morris, John
    ATMOSPHERE, 2023, 14 (03)
  • [34] Field Evaluation of Low-Cost PM Sensors (Purple Air PA-II) Under Variable Urban Air Quality Conditions, in Greece
    Stavroulas, Iasonas
    Grivas, Georgios
    Michalopoulos, Panagiotis
    Liakakou, Eleni
    Bougiatioti, Aikaterini
    Kalkavouras, Panayiotis
    Fameli, Kyriaki Maria
    Hatzianastassiou, Nikolaos
    Mihalopoulos, Nikolaos
    Gerasopoulos, Evangelos
    ATMOSPHERE, 2020, 11 (09)
  • [35] Evaluation of low-cost particulate matter sensors OPC N2 and PM Nova for aerosol monitoring
    Dubey, Ravish
    Patra, Aditya Kumar
    Joshi, Jayadev
    Blankenberg, Daniel
    Kolluru, Soma Sekhara Rao
    Madhu, Badri
    Raval, Simit
    ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (03)
  • [36] Insights into low-cost pm sensors using size-resolved scattering intensity of cooking aerosols in a test house
    Thakur, Alok Kumar
    Gingrich, Jonathan
    Vance, Marina E.
    Patel, Sameer
    AEROSOL SCIENCE AND TECHNOLOGY, 2024, 58 (07) : 739 - 751
  • [37] Field and laboratory evaluation of PurpleAir low-cost aerosol sensors in monitoring indoor airborne particles
    Park, Seongjun
    Lee, Shinhye
    Yeo, Myoungsouk
    Rim, Donghyun
    BUILDING AND ENVIRONMENT, 2023, 234
  • [38] Fine particle mass monitoring with low-cost sensors: Corrections and long-term performance evaluation
    Malings, Carl
    Tanzer, Rebecca
    Hauryliuk, Aliaksei
    Saha, Provat K.
    Robinson, Allen L.
    Presto, Albert A.
    Subramanian, R.
    AEROSOL SCIENCE AND TECHNOLOGY, 2020, 54 (02) : 160 - 174
  • [39] Field performance evaluation of low-cost PM2.5 sensors for enhancing spatial resolution of PM2.5 monitoring: a case study in the smart city of Sejong, Korea
    Sangcheol Kim
    Hayoon Go
    Eunok Bang
    Kyongyong Jung
    Environmental Monitoring and Assessment, 197 (1)
  • [40] Investigating the Sensitivity of Low-Cost Sensors in Measuring Particle Number Concentrations across Diverse Atmospheric Conditions in Greece and Spain
    Kosmopoulos, Georgios
    Salamalikis, Vasileios
    Wilbert, Stefan
    Zarzalejo, Luis F.
    Hanrieder, Natalie
    Karatzas, Stylianos
    Kazantzidis, Andreas
    SENSORS, 2023, 23 (14)