Closed-Loop Force Control by Biorealistic Hand Prosthesis With Visual and Tactile Sensory Feedback

被引:0
|
作者
Zhang, Zhuozhi [1 ]
Xie, Anran [1 ]
Chou, Chih-Hong [1 ]
Liang, Wenyuan [2 ]
Zhang, Jie [1 ]
Bi, Sheng [2 ]
Lan, Ning [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Lab NeuroRehabil Engn, Shanghai 200030, Peoples R China
[2] Natl Res Ctr Rehabil Tech Aids, Beijing 100176, Peoples R China
关键词
Force; Task analysis; Prosthetic hand; Muscles; Visualization; Thumb; Force control; Digital twin; virtual prosthesis; biorealistic control; evoked tactile sensation; multi-sensory integration; MYOELECTRIC PROSTHESIS; MODEL; MUSCLE;
D O I
10.1109/TNSRE.2024.3439722
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability of a novel biorealistic hand prosthesis for grasp force control reveals improved neural compatibility between the human-prosthetic interaction. The primary purpose here was to validate a virtual training platform for amputee subjects and evaluate the respective roles of visual and tactile information in fundamental force control tasks. We developed a digital twin of tendon-driven prosthetic hand in the MuJoCo environment. Biorealistic controllers emulated a pair of antagonistic muscles controlling the index finger of the virtual hand by surface electromyographic (sEMG) signals from amputees' residual forearm muscles. Grasp force information was transmitted to amputees through evoked tactile sensation (ETS) feedback. Six forearm amputees participated in force tracking and holding tasks under different feedback conditions or using their intact hands. Test results showed that visual feedback played a predominant role than ETS feedback in force tracking and holding tasks. However, in the absence of visual feedback during the force holding task, ETS feedback significantly enhanced motor performance compared to feedforward control alone. Thus, ETS feedback still supplied reliable sensory information to facilitate amputee's ability of stable grasp force control. The effects of tactile and visual feedback on force control were subject-specific when both types of feedback were provided simultaneously. Amputees were able to integrate visual and tactile information to the biorealistic controllers and achieve a good sensorimotor performance in grasp force regulation. The virtual platform may provide a training paradigm for amputees to adapt the biorealistic hand controller and ETS feedback optimally.
引用
收藏
页码:2939 / 2949
页数:11
相关论文
共 50 条
  • [31] Closed-loop learning of visual control policies
    Jodogne, Sébastien
    Piater, Justus H.
    Journal of Artificial Intelligence Research, 1600, 28 : 349 - 391
  • [32] Closed-loop learning of visual control policies
    Jodogne, Sebastien
    Piater, Justus H.
    JOURNAL OF ARTIFICIAL INTELLIGENCE RESEARCH, 2007, 28 : 349 - 391
  • [33] Closed-Loop Control of a Neuroprosthetic Hand by Magnetoencephalographic Signals
    Fukuma, Ryohei
    Yanagisawa, Takufumi
    Yorifuji, Shiro
    Kato, Ryu
    Yokoi, Hiroshi
    Hirata, Masayuki
    Saitoh, Youichi
    Kishima, Haruhiko
    Kamitani, Yukiyasu
    Yoshimine, Toshiki
    PLOS ONE, 2015, 10 (07):
  • [34] The Role of Closed-Loop Hand Control in Handshaking Interactions
    Vigni, Francesco
    Knoop, Espen
    Prattichizzo, Domenico
    Malvezzi, Monica
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2019, 4 (02) : 878 - 885
  • [35] Hybrid closed-loop control of robotic hand regrasping
    Schlegl, T
    Buss, M
    1998 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, 1998, : 3026 - 3031
  • [36] Hand Sensory Rehabilitation System Which Incorporated Visual and Tactile Feedback
    Hagiwara, Yuta
    Takeda, Keisuke
    Yamamoto, Shinichiro
    Saito, Yukio
    PROCEEDINGS 2018 12TH FRANCE-JAPAN AND 10TH EUROPE-ASIA CONGRESS ON MECHATRONICS, 2018, : 346 - 351
  • [37] Predictability is necessary for closed-loop visual feedback delay adaptation
    Rohde, Marieke
    van Dam, Loes C. J.
    Ernst, Marc O.
    JOURNAL OF VISION, 2014, 14 (03):
  • [38] Neuromimetic Event-Based Detection for Closed-Loop Tactile Feedback Control of Upper Limb Prostheses
    Osborn, Luke
    Kaliki, Rahul R.
    Soares, Alcimar B.
    Thakor, Nitish V.
    IEEE TRANSACTIONS ON HAPTICS, 2016, 9 (02) : 196 - 206
  • [39] Online Closed-Loop Control Using Tactile Feedback Delivered Through Surface and Subdermal Electrotactile Stimulation
    Dong, Jian
    Jensen, Winnie
    Geng, Bo
    Kamavuako, Ernest Nlandu
    Dosen, Strahinja
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [40] CLOSED-LOOP MANIPULATOR CONTROL USING QUATERNION FEEDBACK
    YUAN, JSC
    IEEE JOURNAL OF ROBOTICS AND AUTOMATION, 1988, 4 (04): : 434 - 440