Closed-Loop Force Control by Biorealistic Hand Prosthesis With Visual and Tactile Sensory Feedback

被引:0
|
作者
Zhang, Zhuozhi [1 ]
Xie, Anran [1 ]
Chou, Chih-Hong [1 ]
Liang, Wenyuan [2 ]
Zhang, Jie [1 ]
Bi, Sheng [2 ]
Lan, Ning [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Lab NeuroRehabil Engn, Shanghai 200030, Peoples R China
[2] Natl Res Ctr Rehabil Tech Aids, Beijing 100176, Peoples R China
关键词
Force; Task analysis; Prosthetic hand; Muscles; Visualization; Thumb; Force control; Digital twin; virtual prosthesis; biorealistic control; evoked tactile sensation; multi-sensory integration; MYOELECTRIC PROSTHESIS; MODEL; MUSCLE;
D O I
10.1109/TNSRE.2024.3439722
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability of a novel biorealistic hand prosthesis for grasp force control reveals improved neural compatibility between the human-prosthetic interaction. The primary purpose here was to validate a virtual training platform for amputee subjects and evaluate the respective roles of visual and tactile information in fundamental force control tasks. We developed a digital twin of tendon-driven prosthetic hand in the MuJoCo environment. Biorealistic controllers emulated a pair of antagonistic muscles controlling the index finger of the virtual hand by surface electromyographic (sEMG) signals from amputees' residual forearm muscles. Grasp force information was transmitted to amputees through evoked tactile sensation (ETS) feedback. Six forearm amputees participated in force tracking and holding tasks under different feedback conditions or using their intact hands. Test results showed that visual feedback played a predominant role than ETS feedback in force tracking and holding tasks. However, in the absence of visual feedback during the force holding task, ETS feedback significantly enhanced motor performance compared to feedforward control alone. Thus, ETS feedback still supplied reliable sensory information to facilitate amputee's ability of stable grasp force control. The effects of tactile and visual feedback on force control were subject-specific when both types of feedback were provided simultaneously. Amputees were able to integrate visual and tactile information to the biorealistic controllers and achieve a good sensorimotor performance in grasp force regulation. The virtual platform may provide a training paradigm for amputees to adapt the biorealistic hand controller and ETS feedback optimally.
引用
收藏
页码:2939 / 2949
页数:11
相关论文
共 50 条
  • [41] Proportional closed-loop feedback control of flow separation
    Pinier, Jeremy T.
    Ausseur, Julie M.
    Glauser, Mark N.
    Higuchi, Hiroshi
    AIAA JOURNAL, 2007, 45 (01) : 181 - 190
  • [42] Real-time adaptive cancellation of TENS feedback artifact on sEMG for prosthesis closed-loop control
    Lee, Byungwook
    Kim, Kyung-Soo
    Cho, Younggeol
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [43] Closed-Loop Control of a Multifunctional Myoelectric Prosthesis With Full-State Anatomically Congruent Electrotactile Feedback
    Garenfeld, Martin A.
    Strbac, Matija
    Jorgovanovic, Nikola
    Dideriksen, Jakob L.
    Dosen, Strahinja
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 2090 - 2100
  • [44] Adaptive closed-loop power control with quantized feedback and loop filtering
    Su, HJ
    Geraniotis, E
    IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2002, 1 (01) : 76 - 86
  • [45] Adaptive closed-loop power control with quantized feedback and loop filtering
    Su, HJ
    Geraniotis, E
    NINTH IEEE INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR AND MOBILE RADIO COMMUNICATIONS, VOLS 1-3, 1998, : 926 - 931
  • [46] Simplified Closed-loop Thermal Feedback System in Flexible Form Factor for Prosthesis
    Park, Wooyoung
    Yu, Xinge
    2023 IEEE 23RD INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY, NANO, 2023, : 311 - 316
  • [47] Deceleration-feedback braking force closed-loop control method for urban rail train
    Ma T.
    Wu M.
    Tian C.
    Tian, Chun (chtian@tongji.edu.cn), 1600, Science Press (42): : 197 - 205
  • [48] Biorealistic Control of Hand Prosthesis Augments Functional Performance of Individuals With Amputation
    Luo, Qi
    Niu, Chuanxin M.
    Chou, Chih-Hong
    Liang, Wenyuan
    Deng, Xiaoqian
    Hao, Manzhao
    Lan, Ning
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [49] Passivity-based Visual Feedback Control for an Endpoint Closed-loop System with a Movable Camera
    Kuroda, Mamoru
    Murao, Toshiyuki
    Kawai, Hiroyuki
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 2410 - 2415
  • [50] LMI-BASED TRAJECTORY PLANNING FOR CLOSED-LOOP CONTROL OF ROBOTIC SYSTEMS WITH VISUAL FEEDBACK
    Chesi, Graziano
    ICINCO 2009: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 2: ROBOTICS AND AUTOMATION, 2009, : 13 - 20