A New Remote Monitoring System: Evaluation of the Efficiency and Accuracy of the Smart Emergency Medical System-Health Internet of Things Device

被引:0
|
作者
Goudarzi, Mohammad Taghi Hedayati [1 ]
Marzouni, Hadi Zare [2 ]
Tarkhan, Fazel [3 ]
Bijani, Ali [4 ]
Babagoli, Mehdi [5 ]
Shadifar, Amirhossein [6 ]
Alipour, Javad Abbas [7 ]
机构
[1] Babol Univ Med Sci, Rohani Hosp, Sch Med, Cardiol Dept, Babol, Iran
[2] Birjand Univ Med Sci, Qaen Fac Med Sci, Birjand, Iran
[3] Babol Univ Med Sci, Hlth Res Inst, Biomed & Microbial Adv Technol Res Ctr, Babol, Iran
[4] Babol Univ Med Sci, Hlth Res Inst, Social Determinants Hlth Res Ctr, Dept Epidemiol, Babol, Iran
[5] KN Toosi Univ Technol, Dept Ind Engn, IT Engn Grp, Tehran, Iran
[6] Babol Noshirvani Univ Technol, Fac Elect Engn, Dept Elect & Comp Engn, Babol, Iran
[7] Babol Univ Med Sci, Clin Res Dev Unit, Rouhani Hosp, Babol, Iran
来源
GALEN MEDICAL JOURNAL | 2024年 / 13卷
关键词
Cardiovascular Disease; Telemedicine; Telehealth; Arrhythmias; TELEMEDICINE; TRIAL; CARE;
D O I
10.31661/gmj.v13i.3376
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The remote medical monitoring system can facilitate monitoring patients with cardiac arrhythmia, and consequently, reduce mortality and complications in individuals requiring emergency interventions. Hence, it is necessary to evaluate new telemedicine devices and compare them with standard devices. Therefore, this study aimed to evaluate and compare the new remote monitoring system, Smart Emergency Medical System-Health Internet of Things (SEMS-HIOT) developed by the Health Technology Development Centre of Babol University of Medical Sciences on patients with different cardiac arrhythmias and compare it with the standard device. Materials and Methods: In this case-control study, 60 patients were divided into the six most common arrhythmia groups (n=10 per each group and equal gender) as atrial fibrillation, ventricular tachycardia, paroxysmal supraventricular tachycardia, premature ventricular contractions, atrial tachycardia, and premature atrial contractions. Also, 20 healthy individuals (including 10 men and 10 women) without any arrhythmia (normal rhythm) were considered as the control group. Three similar SEMS-HIOT devices were used as test devices and a standard cardiac monitoring device as the control device. The clinical parameters, including heart rate, pulse rate, oxygen saturation, body temperature, and cardiac electrical activity via electrocardiogram (ECG) lead-II were recorded. Results: Findings showed that the performance of the SEMSHIOT test device was similar and in the same range for all indices in each group and there were no significant differences compared to the performance of the control device (P>0.05). Also, the ECG records measured with SEMS-HIOT and standard device indicate no significant differences (P>0.05). Conclusion: Our study showed that the cardiac indices as well as ECG findings, which were measured with SEMS-HIOT and common standard devices confirmed the accuracy and reliability of the new telematics device for monitoring patients with cardiac diseases.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] An Internet-of-Things Enabled Smart Sensing System for Nitrate Monitoring
    Alahi, Md. Eshrat E.
    Pereira-Ishak, Najid
    Mukhopadhyay, Subhas Chandra
    Burkitt, Lucy
    IEEE INTERNET OF THINGS JOURNAL, 2018, 5 (06): : 4409 - 4417
  • [42] Smart Greenhouse Monitoring System Using Internet of Things and Artificial Intelligence
    Sultana Jahan Soheli
    Nusrat Jahan
    Md. Bipul Hossain
    Apurba Adhikary
    Ashikur Rahman Khan
    M. Wahiduzzaman
    Wireless Personal Communications, 2022, 124 : 3603 - 3634
  • [43] Internet of Things for education: A smart and secure system for schools monitoring and alerting
    Qureshi, Kashif Naseer
    Naveed, Ayesha
    Kashif, Yamna
    Jeon, Gwanggil
    COMPUTERS & ELECTRICAL ENGINEERING, 2021, 93
  • [44] EMAS: Environment Monitoring and Smart Alert System for Internet of Things (IoT)
    Tahir, Muhammad
    Enam, Rabia Noor
    Mustafa, Syed Muhammad Nabeel
    Javed, Rukaiya
    2020 GLOBAL CONFERENCE ON WIRELESS AND OPTICAL TECHNOLOGIES (GCWOT), 2020,
  • [45] Internet of Things Gateway Edge for Movement Monitoring in a Smart Healthcare System
    Al-Naime, Khalid
    Al-Anbuky, Adnan
    Mawston, Grant
    ELECTRONICS, 2023, 12 (16)
  • [46] Smart Water Monitoring and Management System Based on the Architecture of Internet of Things
    Cui, Bo
    Meng, Qinghong
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 1822 - 1825
  • [47] Vehicle Monitoring System Based on Internet of Things (IoT) for Smart Cities
    Zalke, Jitendra
    Anjankar, Shubham C.
    Pandey, Sandeepkumar R.
    Misal, Noopoor
    Jawarkar, Parag
    HELIX, 2020, 10 (01): : 222 - 227
  • [48] Crowdsourcing Medical Emergency System using Internet of Things in Bangladesh Perspective
    Zaman, Md. Arif Uz
    Yesmin, Romana
    Hasan, Sadman Sakib
    Sadi, Sadman Hoque
    Sabuj, Saifur Rahman
    2018 IEEE 5TH INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATION (ICSIMA), 2018,
  • [49] Design of a Novel Remote Monitoring System for Smart Greenhouses Using the Internet of Things and Deep Convolutional Neural Networks
    Mellit, Adel
    Benghanem, Mohamed
    Herrak, Omar
    Messalaoui, Abdelaziz
    ENERGIES, 2021, 14 (16)
  • [50] SensorMon: An Internet-of-Things System for Maintaining and Monitoring Sensor Device
    Jing, Changfeng
    Dong, Meng
    Du, Mingyi
    Wang, Jian
    Zhu, Yanli
    SENSORS AND MATERIALS, 2019, 31 (10) : 3261 - 3271