Variations in head tilt during the acquisition of cone beam computed tomography scans and their effects on effective radiation dose

被引:0
|
作者
Mancini, Arthur X. M. [1 ]
Carmozini, Gabriela A. [2 ]
Inacio, Thiago M. [2 ]
Rea, Marcela T. [3 ]
Viccari, Cassiana [4 ]
Brasil, Danieli M. [5 ]
Oliveira-Santos, Christiano [5 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthodont, Av Do Cafe S-N, BR-14040904 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol Publ Oral Hlth & Forens Dent, BR-14040904 Ribeirao Preto, SP, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, BR-13414903 Piracicaba, SP, Brazil
[4] Univ Sao Paulo, Ctr Instrumentat Dosimetry & Radioprotect CIDRA, BR-14040904 Ribeirao Preto, SP, Brazil
[5] Univ Louisville, Sch Dent, Dept Diag & Oral Hlth, Louisville, KY 40208 USA
基金
巴西圣保罗研究基金会;
关键词
cone beam computed tomography; effective dose; head inclination; IMAGE QUALITY; CBCT DEVICES; CT; DOSIMETRY; POSITION;
D O I
10.1093/dmfr/twae043
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study evaluated the impact of variations in anteroposterior and lateral tilts of patients head on radiation-weighted doses to organs/tissues and effective doses using 3 different cone beam computed tomography (CBCT) machines.Methods An anthropomorphic phantom was used to estimate radiation doses in 3 CBCT machines (OP300, Eagle X 3D, and Eagle Edge). Thermoluminescent dosimeters were placed in regions corresponding to pre-stablished organ/tissues. CBCT examinations from the posterior mandible and anterior maxilla regions were acquired, with 3 different anteroposterior angulations (0 degrees, 30 degrees, and 45 degrees), and from the posterior mandible in 3 different lateral angulations (0 degrees, 20 degrees to the left, and 20 degrees to the right side). Radiation-weighted doses for each organ/tissue and effective doses were calculated for each machine and angulation.Results For the posterior mandible acquisitions, anteroposterior angulations of the head at 30 degrees and 45 degrees yielded a reduction in effective doses in all 3 devices. A 20 degrees tilt to the right side resulted in lower doses than to the left [same side as the field of view (FOV)]. For the anterior maxilla, increased anteroposterior angulation was associated with reduction in effective dose in 2 devices.Conclusions Effective doses are lower when small FOV CBCT exams of the posterior mandible and anterior maxilla are acquired with increased anteroposterior head angulation at 30 degrees and 45 degrees. For FOV in the posterior mandible, a 20 degrees lateral tilt towards the side opposite to the FOV also yields lower effective doses. The main contribution to these dose reductions is the decrease in dose to salivary glands.
引用
收藏
页码:566 / 572
页数:7
相关论文
共 50 条
  • [31] The effect of varying cone beam computed tomography image resolution and field-of-view centralization on effective radiation dose
    Jadu, Fatima M.
    Alzahrani, Asmaa A.
    Almutairi, Maha A.
    Al-Amoudi, Salma O.
    Jan, Ahmed M.
    Khafaji, Mawya A.
    SAUDI MEDICAL JOURNAL, 2018, 39 (05) : 470 - 475
  • [32] Estimating the Effective Radiation Dose Imparted to Patients by Intraoperative Cone-Beam Computed Tomography in Thoracolumbar Spinal Surgery
    Lange, Jeffrey
    Karellas, Andrew
    Street, John
    Eck, Jason C.
    Lapinsky, Anthony
    Connolly, Patrick J.
    DiPaola, Christian P.
    SPINE, 2013, 38 (05) : E306 - E312
  • [33] A systematic review comparing the effective radiation dose of musculoskeletal cone beam computed tomography to other diagnostic imaging modalities
    Mason, K.
    Iball, G.
    Hinchcliffe, D.
    Snaith, B.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 177
  • [34] A Monte Carlo study of organ and effective doses of cone beam computed tomography (CBCT) scans in radiotherapy
    Abuhaimed, Abdullah
    Martin, Colin J.
    Sankaralingam, Marimuthu
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (01) : 61 - 80
  • [35] Impact of acquisition protocols on accuracy of dose calculation based on xvi cone beam computed tomography
    Souleyman, Slimani
    Maria, Khalal Dorea
    Cheikh, Tyeb
    Karima, Khalal-Kouache
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (02) : 94 - 104
  • [36] Radiation dose of cone-beam computed tomography compared to conventional radiographs in orthodontics
    Signorelli, Luca
    Patcas, Raphael
    Peltomaki, Timo
    Schaetzle, Marc
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2016, 77 (01): : 9 - 15
  • [37] Evaluation of Radiation Dose and Image Quality for TheVarian Cone Beam Computed Tomography System
    Cheng, H.
    Wu, V.
    Liu, E.
    Kwong, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [38] Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    Islam, Mohammad K.
    Purdie, Thomas G.
    Norrlinger, Bernhard D.
    Alasti, Hamideh
    Moseley, Douglas J.
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Jaffray, David A.
    MEDICAL PHYSICS, 2006, 33 (06) : 1573 - 1582
  • [39] Cone-Beam Computed Tomography and Radiographs in Dentistry: Aspects Related to Radiation Dose
    Coelho Lorenzoni, Diego
    Maria Bolognese, Ana
    Gamba Garib, Daniela
    Ribeiro Guedes, Fabio
    Franzotti Sant'Anna, Eduardo
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [40] EVALUATION OF RADIATION DOSE AND IMAGE QUALITY FOR THE VARIAN CONE BEAM COMPUTED TOMOGRAPHY SYSTEM
    Cheng, Harry C. Y.
    Wu, Vincent W. C.
    Liu, Eva S. F.
    Kwong, Dora L. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 291 - 300