Variations in head tilt during the acquisition of cone beam computed tomography scans and their effects on effective radiation dose

被引:0
|
作者
Mancini, Arthur X. M. [1 ]
Carmozini, Gabriela A. [2 ]
Inacio, Thiago M. [2 ]
Rea, Marcela T. [3 ]
Viccari, Cassiana [4 ]
Brasil, Danieli M. [5 ]
Oliveira-Santos, Christiano [5 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthodont, Av Do Cafe S-N, BR-14040904 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol Publ Oral Hlth & Forens Dent, BR-14040904 Ribeirao Preto, SP, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, BR-13414903 Piracicaba, SP, Brazil
[4] Univ Sao Paulo, Ctr Instrumentat Dosimetry & Radioprotect CIDRA, BR-14040904 Ribeirao Preto, SP, Brazil
[5] Univ Louisville, Sch Dent, Dept Diag & Oral Hlth, Louisville, KY 40208 USA
基金
巴西圣保罗研究基金会;
关键词
cone beam computed tomography; effective dose; head inclination; IMAGE QUALITY; CBCT DEVICES; CT; DOSIMETRY; POSITION;
D O I
10.1093/dmfr/twae043
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study evaluated the impact of variations in anteroposterior and lateral tilts of patients head on radiation-weighted doses to organs/tissues and effective doses using 3 different cone beam computed tomography (CBCT) machines.Methods An anthropomorphic phantom was used to estimate radiation doses in 3 CBCT machines (OP300, Eagle X 3D, and Eagle Edge). Thermoluminescent dosimeters were placed in regions corresponding to pre-stablished organ/tissues. CBCT examinations from the posterior mandible and anterior maxilla regions were acquired, with 3 different anteroposterior angulations (0 degrees, 30 degrees, and 45 degrees), and from the posterior mandible in 3 different lateral angulations (0 degrees, 20 degrees to the left, and 20 degrees to the right side). Radiation-weighted doses for each organ/tissue and effective doses were calculated for each machine and angulation.Results For the posterior mandible acquisitions, anteroposterior angulations of the head at 30 degrees and 45 degrees yielded a reduction in effective doses in all 3 devices. A 20 degrees tilt to the right side resulted in lower doses than to the left [same side as the field of view (FOV)]. For the anterior maxilla, increased anteroposterior angulation was associated with reduction in effective dose in 2 devices.Conclusions Effective doses are lower when small FOV CBCT exams of the posterior mandible and anterior maxilla are acquired with increased anteroposterior head angulation at 30 degrees and 45 degrees. For FOV in the posterior mandible, a 20 degrees lateral tilt towards the side opposite to the FOV also yields lower effective doses. The main contribution to these dose reductions is the decrease in dose to salivary glands.
引用
收藏
页码:566 / 572
页数:7
相关论文
共 50 条
  • [41] Image quality vs radiation dose of four cone beam computed tomography scanners
    Loubele, M.
    Jacobs, R.
    Maes, F.
    Denis, K.
    White, S.
    Coudyzer, W.
    Lambrichts, I.
    van Steenberghe, D.
    Suetens, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (06) : 309 - 318
  • [42] Understanding and communicating radiation dose and risk from cone beam computed tomography in dentistry
    Aanenson, Jill Weber
    Till, John E.
    Grogan, Helen A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 353 - 360
  • [43] Automated Orientation and Registration of Cone-Beam Computed Tomography Scans
    Anchling, Luc
    Hutin, Nathan
    Huang, Yanjie
    Barone, Selene
    Roberts, Sophie
    Miranda, Felicia
    Gurgel, Marcela
    Al Turkestani, Najla
    Tinawi, Sara
    Bianchi, Jonas
    Yatabe, Marilia
    Ruellas, Antonio
    Prieto, Juan Carlos
    Cevidanes, Lucia
    CLINICAL IMAGE-BASED PROCEDURES, FAIRNESS OF AI IN MEDICAL IMAGING, AND ETHICAL AND PHILOSOPHICAL ISSUES IN MEDICAL IMAGING, CLIP 2023, FAIMI 2023, EPIMI 2023, 2023, 14242 : 43 - 58
  • [44] Virtual Tooth Extraction from Cone Beam Computed Tomography Scans
    Orlowska, Marta
    Jozwiak, Rafal
    Regulski, Piotr
    RECENT DEVELOPMENTS AND ACHIEVEMENTS IN BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2018, 647 : 275 - 285
  • [45] Feasibility of the Use of Scatter Corrected Cone Beam Computed Tomography Images to Evaluate Range Variations During Proton Radiation Therapy of Head and Neck Patients
    Kim, J.
    Park, Y. K.
    Sharp, G. C.
    Busse, P. M.
    Winey, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E672 - E672
  • [46] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Anna M. Sailer
    Geert Willem H. Schurink
    Joachim E. Wildberger
    Rick de Graaf
    Willem H. van Zwam
    Michiel W. de Haan
    Gerrit J. Kemerink
    Cécile R. L. P. N. Jeukens
    CardioVascular and Interventional Radiology, 2015, 38 : 112 - 120
  • [47] Computed Tomography of the Head A Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose
    Dieckmeyer, Michael
    Sollmann, Nico
    Kupfer, Karina J.
    Loeffler, Maximilian T.
    Paprottka, Karolin J.
    Kirschke, Jan S.
    Baum, Thomas
    CLINICAL NEURORADIOLOGY, 2023, 33 (03) : 591 - 610
  • [48] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Sailer, Anna M.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    de Graaf, Rick
    van Zwam, Willem H.
    de Haan, Michiel W.
    Kemerink, Gerrit J.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 112 - 120
  • [49] Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans
    Veldhoen, Simon
    Schoellchen, Maximilian
    Hanken, H.
    Precht, C.
    Henes, F. O.
    Schoen, G.
    Nagel, H. D.
    Schumacher, U.
    Heiland, M.
    Adam, G.
    Regier, M.
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 790 - 800
  • [50] Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans
    Simon Veldhoen
    Maximilian Schöllchen
    H. Hanken
    C. Precht
    F. O. Henes
    G. Schön
    H. D. Nagel
    U. Schumacher
    M. Heiland
    G. Adam
    M. Regier
    European Radiology, 2017, 27 : 790 - 800