Deep learning image reconstruction for low-kiloelectron volt virtual monoenergetic images in abdominal dual-energy CT: medium strength provides higher lesion conspicuity

被引:1
|
作者
Zhong, Jingyu [1 ]
Hu, Yangfan [1 ]
Xing, Yue [1 ]
Wang, Lingyun [2 ]
Li, Jianying [3 ]
Lu, Wei [4 ]
Shi, Xiaomeng [5 ]
Ding, Defang [1 ]
Ge, Xiang [1 ]
Zhang, Huan [2 ]
Yao, Weiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai 200336, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Radiol, Shanghai, Peoples R China
[3] GE Healthcare, Computed Tomog Res Ctr, Beijing, Peoples R China
[4] GE Healthcare, Computed Tomog Res Ctr, Shanghai, Peoples R China
[5] Imperial Coll London, Dept Mat, London, England
基金
中国国家自然科学基金;
关键词
Multidetector computed tomography; deep learning; image reconstruction; contrast enhancement; QUALITY;
D O I
10.1177/02841851241262765
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The best settings of deep learning image reconstruction (DLIR) algorithm for abdominal low-kiloelectron volt (keV) virtual monoenergetic imaging (VMI) have not been determined. Purpose To determine the optimal settings of the DLIR algorithm for abdominal low-keV VMI. Material and Methods The portal-venous phase computed tomography (CT) scans of 109 participants with 152 lesions were reconstructed into four image series: VMI at 50 keV using adaptive statistical iterative reconstruction (Asir-V) at 50% blending (AV-50); and VMI at 40 keV using AV-50 and DLIR at medium (DLIR-M) and high strength (DLIR-H). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of nine anatomical sites were calculated. Noise power spectrum (NPS) using homogenous region of liver, and edge rise slope (ERS) at five edges were measured. Five radiologists rated image quality and diagnostic acceptability, and evaluated the lesion conspicuity. Results The SNR and CNR values, and noise and noise peak in NPS measurements, were significantly lower in DLIR images than AV-50 images in all anatomical sites (all P < 0.001). The ERS values were significantly higher in 40-keV images than 50-keV images at all edges (all P < 0.001). The differences of the peak and average spatial frequency among the four reconstruction algorithms were significant but relatively small. The 40-keV images were rated higher with DLIR-M than DLIR-H for diagnostic acceptance (P < 0.001) and lesion conspicuity (P = 0.010). Conclusion DLIR provides lower noise, higher sharpness, and more natural texture to allow 40 keV to be a new standard for routine VMI reconstruction for the abdomen and DLIR-M gains higher diagnostic acceptance and lesion conspicuity rating than DLIR-H.
引用
收藏
页码:1133 / 1146
页数:14
相关论文
共 50 条
  • [31] Deep-learning reconstruction enhances image quality of Adamkiewicz Artery in low-keV dual-energy CT
    Tatsugami, Fuminari
    Higaki, Toru
    Kawashita, Ikuo
    Fujioka, Chikako
    Nakamura, Yuko
    Takahashi, Shinya
    Awai, Kazuo
    ACTA RADIOLOGICA, 2024, : 1569 - 1575
  • [32] Comparison of virtual monoenergetic imaging between a rapid kilovoltage switching dual-energy computed tomography with deep-learning and four dual-energy CTs with iterative reconstruction
    Greffier, Joel
    Si-Mohamed, Salim
    Guiu, Boris
    Frandon, Julien
    Loisy, Maeliss
    de Oliveira, Fabien
    Douek, Philippe
    Beregi, Jean-Paul
    Dabli, Djamel
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1149 - +
  • [33] Dual-energy computed tomography with new virtual monoenergetic image reconstruction enhances prostate lesion image quality and improves the diagnostic efficacy for prostate cancer
    Fan, Nina
    Chen, Xiaofeng
    Li, Yulin
    Zhu, Zhiqiang
    Chen, Xiangguang
    Yang, Zhiqi
    Yang, Jiada
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [34] Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen
    Sato, Mineka
    Ichikawa, Yasutaka
    Domae, Kensuke
    Yoshikawa, Kazuya
    Kanii, Yoshinori
    Yamazaki, Akio
    Nagasawa, Naoki
    Nagata, Motonori
    Ishida, Masaki
    Sakuma, Hajime
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5499 - 5507
  • [35] Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen
    Mineka Sato
    Yasutaka Ichikawa
    Kensuke Domae
    Kazuya Yoshikawa
    Yoshinori Kanii
    Akio Yamazaki
    Naoki Nagasawa
    Motonori Nagata
    Masaki Ishida
    Hajime Sakuma
    European Radiology, 2022, 32 : 5499 - 5507
  • [36] Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT
    Gong, Hao
    Marsh, Jeffrey F.
    D'Souza, Karen N.
    Huber, Nathan R.
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
  • [37] Image Quality Evaluation in Dual-Energy CT of the Chest, Abdomen, and Pelvis in Obese Patients With Deep Learning Image Reconstruction
    Fair, Eric
    Profio, Mark
    Kulkarni, Naveen
    Laviolette, Peter S.
    Barnes, Bret
    Bobholz, Samuel
    Levenhagen, Maureen
    Ausman, Robin
    Griffin, Michael O.
    Duvnjak, Petar
    Zorn, Adam P.
    Foley, W. Dennis
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (04) : 604 - 611
  • [38] Low keV portal venous phase as a surrogate for pancreatic phase in a pancreatic protocol dual-energy CT: feasibility, image quality, and lesion conspicuity
    Yoshifumi Noda
    Toru Tochigi
    Anushri Parakh
    Evita Joseph
    Peter F. Hahn
    Avinash Kambadakone
    European Radiology, 2021, 31 : 6898 - 6908
  • [39] Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT
    Zhong, Jingyu
    Shen, Hailin
    Chen, Yong
    Xia, Yihan
    Shi, Xiaomeng
    Lu, Wei
    Li, Jianying
    Xing, Yue
    Hu, Yangfan
    Ge, Xiang
    Ding, Defang
    Jiang, Zhenming
    Yao, Weiwu
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (04) : 1390 - 1407
  • [40] Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT
    Jingyu Zhong
    Hailin Shen
    Yong Chen
    Yihan Xia
    Xiaomeng Shi
    Wei Lu
    Jianying Li
    Yue Xing
    Yangfan Hu
    Xiang Ge
    Defang Ding
    Zhenming Jiang
    Weiwu Yao
    Journal of Digital Imaging, 2023, 36 : 1390 - 1407