Deep learning image reconstruction for low-kiloelectron volt virtual monoenergetic images in abdominal dual-energy CT: medium strength provides higher lesion conspicuity

被引:1
|
作者
Zhong, Jingyu [1 ]
Hu, Yangfan [1 ]
Xing, Yue [1 ]
Wang, Lingyun [2 ]
Li, Jianying [3 ]
Lu, Wei [4 ]
Shi, Xiaomeng [5 ]
Ding, Defang [1 ]
Ge, Xiang [1 ]
Zhang, Huan [2 ]
Yao, Weiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai 200336, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Radiol, Shanghai, Peoples R China
[3] GE Healthcare, Computed Tomog Res Ctr, Beijing, Peoples R China
[4] GE Healthcare, Computed Tomog Res Ctr, Shanghai, Peoples R China
[5] Imperial Coll London, Dept Mat, London, England
基金
中国国家自然科学基金;
关键词
Multidetector computed tomography; deep learning; image reconstruction; contrast enhancement; QUALITY;
D O I
10.1177/02841851241262765
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The best settings of deep learning image reconstruction (DLIR) algorithm for abdominal low-kiloelectron volt (keV) virtual monoenergetic imaging (VMI) have not been determined. Purpose To determine the optimal settings of the DLIR algorithm for abdominal low-keV VMI. Material and Methods The portal-venous phase computed tomography (CT) scans of 109 participants with 152 lesions were reconstructed into four image series: VMI at 50 keV using adaptive statistical iterative reconstruction (Asir-V) at 50% blending (AV-50); and VMI at 40 keV using AV-50 and DLIR at medium (DLIR-M) and high strength (DLIR-H). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of nine anatomical sites were calculated. Noise power spectrum (NPS) using homogenous region of liver, and edge rise slope (ERS) at five edges were measured. Five radiologists rated image quality and diagnostic acceptability, and evaluated the lesion conspicuity. Results The SNR and CNR values, and noise and noise peak in NPS measurements, were significantly lower in DLIR images than AV-50 images in all anatomical sites (all P < 0.001). The ERS values were significantly higher in 40-keV images than 50-keV images at all edges (all P < 0.001). The differences of the peak and average spatial frequency among the four reconstruction algorithms were significant but relatively small. The 40-keV images were rated higher with DLIR-M than DLIR-H for diagnostic acceptance (P < 0.001) and lesion conspicuity (P = 0.010). Conclusion DLIR provides lower noise, higher sharpness, and more natural texture to allow 40 keV to be a new standard for routine VMI reconstruction for the abdomen and DLIR-M gains higher diagnostic acceptance and lesion conspicuity rating than DLIR-H.
引用
收藏
页码:1133 / 1146
页数:14
相关论文
共 50 条
  • [21] CT-based thermometry with virtual monoenergetic images by dual-energy of fat, muscle and bone using FBP, iterative and deep learning-based reconstruction
    Heinrich, Andreas
    Schenkl, Sebastian
    Buckreus, David
    Guettler, Felix V.
    Teichgraeber, Ulf K-M.
    EUROPEAN RADIOLOGY, 2022, 32 (01) : 424 - 431
  • [22] Advanced Virtual Monochromatic Images from Dual Source Dual-Energy CT for a Reduction in the Contrast Medium Dose (389 mgI/kg) in Multiphase Liver CT: Evaluation of Image Quality and Focal Lesion Conspicuity
    Kim, Ji Eun
    Kim, Hyun Ok
    Bae, Kyungsoo
    Cho, Jae Min
    Choi, Ho Cheol
    Choi, Dae Seob
    Na, Jaebeom
    IRANIAN JOURNAL OF RADIOLOGY, 2019, 16 (03)
  • [23] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +
  • [24] A Deep Learning Image Reconstruction Algorithm for Improving Image Quality and Hepatic Lesion Detectability in Abdominal Dual-Energy Computed Tomography: Preliminary Results
    Chu, Bingqian
    Gan, Lu
    Shen, Yi
    Song, Jian
    Liu, Ling
    Li, Jianying
    Liu, Bin
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (06) : 2347 - 2355
  • [25] A Deep Learning Image Reconstruction Algorithm for Improving Image Quality and Hepatic Lesion Detectability in Abdominal Dual-Energy Computed Tomography: Preliminary Results
    Bingqian Chu
    Lu Gan
    Yi Shen
    Jian Song
    Ling Liu
    Jianying Li
    Bin Liu
    Journal of Digital Imaging, 2023, 36 : 2347 - 2355
  • [26] Application of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Routine Pancreas Imaging
    Hardie, Andrew D.
    Picard, Melissa M.
    Camp, E. Ramsay
    Perry, Jonathan D.
    Suranyi, Pal
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 716 - 720
  • [27] Pseudo low-energy monochromatic imaging of head and neck cancers: Deep learning image reconstruction with dual-energy CT
    Yuhei Koike
    Shingo Ohira
    Yuri Teraoka
    Ayako Matsumi
    Yasuhiro Imai
    Yuichi Akino
    Masayoshi Miyazaki
    Satoaki Nakamura
    Koji Konishi
    Noboru Tanigawa
    Kazuhiko Ogawa
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1271 - 1279
  • [28] Pseudo low-energy monochromatic imaging of head and neck cancers: Deep learning image reconstruction with dual-energy CT
    Koike, Yuhei
    Ohira, Shingo
    Teraoka, Yuri
    Matsumi, Ayako
    Imai, Yasuhiro
    Akino, Yuichi
    Miyazaki, Masayoshi
    Nakamura, Satoaki
    Konishi, Koji
    Tanigawa, Noboru
    Ogawa, Kazuhiko
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (07) : 1271 - 1279
  • [29] Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study
    G. Jay Hanson
    Gregory J. Michalak
    Robert Childs
    Brian McCollough
    Anil N. Kurup
    David M. Hough
    Judson M. Frye
    Jeff L. Fidler
    Sudhakar K. Venkatesh
    Shuai Leng
    Lifeng Yu
    Ahmed F. Halaweish
    W. Scott Harmsen
    Cynthia H. McCollough
    J. G. Fletcher
    Abdominal Radiology, 2018, 43 : 1404 - 1412
  • [30] Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study
    Hanson, G. Jay
    Michalak, Gregory J.
    Childs, Robert
    McCollough, Brian
    Kurup, Anil N.
    Hough, David M.
    Frye, Judson M.
    Fidler, Jeff L.
    Venkatesh, Sudhakar K.
    Leng, Shuai
    Yu, Lifeng
    Halaweish, Ahmed F.
    Harmsen, W. Scott
    McCollough, Cynthia H.
    Fletcher, J. G.
    ABDOMINAL RADIOLOGY, 2018, 43 (06) : 1404 - 1412