Purpose: We developed a deep learning method to reduce noise and beam-hardening artifact in virtual monoenergetic image (VMI) at low x-ray energy levels. Approach: An encoder-decoder type convolutional neural network was implemented with customized inception modules and in-house-designed training loss (denoted as Incept-net), to directly estimate VMI from multi-energy CT images. Images of an abdomen-sized water phantom with varying insert materials were acquired from a research photon-counting-detector CT. The Incept-net was trained with image patches (64 x 64 pixels) extracted from the phantom data, as well as synthesized, random-shaped numerical insert materials. The whole CT images (512 x 512 pixels) with the remaining real insert materials that were unseen in network training were used for testing. Seven contrast-enhanced abdominal CT exams were used for preliminary evaluation of Incept-net generalizability over anatomical background. Mean absolute percentage error (MAPE) was used to evaluate CT number accuracy. Results: Compared to commercial VMI software, Incept-net largely suppressed beam-hardening artifact and reduced noise (53%) in phantom study. Incept-net presented comparable CT number accuracy at higher-density (P-value [0.0625, 0.999]) and improved it at lower-density inserts (P-value=0.0313) with overall MAPE: Incept-net [2.9%, 4.6%]; commercial-VMI [6.7%, 10.9%]. In patient images, Incept-net suppressed beam-hardening artifact and reduced noise (up to 50%, P-value=0.0156). Conclusion: In this preliminary study, Incept-net presented the potential to improve low-energy VMI quality. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Quantitative accuracy of virtual monoenergetic images from multi-energy CT
    Rajendran, Kishore
    Swicklik, Joseph
    Leng, Shuai
    McCollough, Cynthia
    EUROPEAN RADIOLOGY, 2024, 34 (05) : 2957 - 2959
  • [2] Quantitative accuracy of virtual monoenergetic images from multi-energy CT Reply
    Greffier, Joel
    Yagil, Yoad
    Erhard, Klaus
    Douek, Philippe C.
    Si-Mohamed, Salim A.
    EUROPEAN RADIOLOGY, 2024, 34 (05) : 2960 - 2962
  • [3] Synthetic Virtual Monoenergetic Images Based on Single-Energy CT Via Deep Learning Method
    Gao, Y.
    Xie, H.
    Chang, C. W.
    Qiu, R. L. J.
    Roper, J. R.
    Yu, D.
    Ghavidel, B. Bradshaw
    Patel, P.
    Zhou, J.
    Yang, X.
    MEDICAL PHYSICS, 2024, 51 (10) : 7752 - 7752
  • [4] Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms
    Greffier, Joel
    Van Ngoc Ty, Claire
    Fitton, Isabelle
    Frandon, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (19)
  • [5] DEEP-LEARNING-BASED ENERGY AWARE IMAGES
    Le Meur, Olivier
    Demarty, Claire-Helene
    Blonde, Laurent
    2023 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP, 2023, : 590 - 594
  • [6] Optimized Virtual Monoenergetic Image Generation Via Adversarial Learning in Multi-Energy and Photon Counting Detector CT
    Chang, S.
    Koons, E.
    Gong, H.
    McCollough, C. H.
    Leng, S.
    MEDICAL PHYSICS, 2024, 51 (09) : 6648 - 6648
  • [7] Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (09) : 311 - 318
  • [8] Bi-Objective Dispatch of Multi-Energy Virtual Power Plant: Deep-Learning-Based Prediction and Particle Swarm Optimization
    Zhang, Jiahui
    Xu, Zhiyu
    Xu, Weisheng
    Zhu, Feiyu
    Lyu, Xiaoyu
    FU, Min
    APPLIED SCIENCES-BASEL, 2019, 9 (02):
  • [9] Energy-Specific Optimization of Attenuation Thresholds for Low-Energy Virtual Monoenergetic Images in Renal Lesion Evaluation
    Patel, Bhavik N.
    Farjat, Alfredo
    Schabel, Christoph
    Duvnjak, Petar
    Mileto, Achille
    Ramirez-Giraldo, Juan Carlos
    Marin, Daniele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : W205 - W217
  • [10] Energy Management and Optimization of Multi-energy Grid Based on Deep Reinforcement Learning
    Liu J.
    Chen J.
    Wang X.
    Zeng J.
    Huang Q.
    Dianwang Jishu/Power System Technology, 2020, 44 (10): : 3794 - 3803