Additional multifocal sulcus-based intraocular lens: Alternative to multifocal intraocular lens in the capsular bag

被引:18
|
作者
Schrecker, Jens [1 ]
Kroeber, Sandra [1 ]
Eppig, Timo [2 ]
Langenbucher, Achim [2 ]
机构
[1] Klinikum Rudolf Virchow, Dept Ophthalmol, D-08371 Glauchau, Germany
[2] Univ Saarland, Homburg, Germany
来源
关键词
ADD-ON IOL; PSEUDOPHAKIC EYES; CONTRAST SENSITIVITY; PUPIL SIZE; IMPLANTATION; ASTIGMATISM; ACUITY;
D O I
10.1016/j.jcrs.2012.10.047
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual outcomes of additional multifocal intraocular lenses (IOLs) for sulcus fixation with those of standard multifocal IOLs in the capsular bag. SETTING: Department of Ophthalmology, Rudolf-Virchow-Klinikum Glauchau, Glauchau, Germany. DESIGN: Prospective controlled clinical trial. METHODS: Eyes had phacoemulsification and implantation of a monofocal IOL in the capsular bag and an additional aberration-free diffractive IOL in the ciliary sulcus (multifocal add-on IOL group). Measurements of uncorrected and distance-corrected distance, intermediate, and near visual acuities; contrast sensitivity; and defocus curve were performed 3 months postoperatively. Results were compared with those in eyes with an aberration-correcting diffractive posterior chamber IOL (multifocal PC IOL group). RESULTS: The multifocal add-on IOL group comprised 34 eyes of 20 patients and the multifocal PC IOL group, 31 eyes of 17 patients. Cataract surgery, IOL implantation, and the postoperative course were uneventful in all cases. There were no statistically significant differences in uncorrected and distance-corrected distance, intermediate, or near visual acuities between the 2 groups. The median uncorrected distance visual acuity was 0.00 logMAR in both groups, and the median uncorrected near visual acuity was 0.10 logMAR in both groups. Contrast sensitivity testing yielded significantly better results in the multifocal add-on IOL group, especially at spatial frequencies over 1.5 cycles per degree. Defocus curves were similar in the 2 groups. CONCLUSION: Visual performance with a multifocal diffractive add-on IOL was equivalent to that achieved with a commonly used multifocal diffractive PC IOL.
引用
收藏
页码:548 / 555
页数:8
相关论文
共 50 条
  • [41] Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens
    Wang, Xiao
    Tu, Haixia
    Wang, Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [42] MULTIFOCAL DIFFRACTION CONTACT-LENS AS AN INDICATOR OF THE TOLERANCE OF A MULTIFOCAL DIFFRACTION INTRAOCULAR-LENS
    HAEFLIGER, E
    ROL, P
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1990, 196 (05) : 312 - 313
  • [43] Clinical and Surgical Outcome of a Supplementary Multifocal Intraocular Lens Implanted with a Bag-In-the-Lens Intraocular Lens: 5-Year Follow-Up
    Verdonck, Thomas
    Werner, Liliana
    Ni Dhubhghaill, Sorcha
    Tassignon, Marie-Jose
    OPHTHALMIC RESEARCH, 2021, 64 (03) : 503 - 511
  • [44] Dislocation of capsular bag with intraocular lens and capsular tension ring
    Oner, F. Hakan
    Kocak, Nilufer
    Saatci, A. Osman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (10): : 1756 - 1758
  • [45] Development of a novel multifocal lens using a polarization directed flat lens: possible candidate for a multifocal intraocular lens
    Na, Kyung-Sun
    Lee, Chang Su
    Kim, Da Ran
    Song, Seok Ho
    Cho, Soo Yeon
    Kim, Eun Chul
    Kim, Hyun Seung
    Hwang, Ho Sik
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [46] Development of a novel multifocal lens using a polarization directed flat lens: possible candidate for a multifocal intraocular lens
    Kyung-Sun Na
    Chang Su Lee
    Da Ran Kim
    Seok Ho Song
    Soo Yeon Cho
    Eun Chul Kim
    Hyun Seung Kim
    Ho Sik Hwang
    BMC Ophthalmology, 21
  • [47] Capsular bag-fixated and ciliary sulcus-fixated intraocular lens centration after supplementary intraocular lens implantation in the same eye
    Prager, Franz
    Amon, Michael
    Wiesinger, Joerg
    Wetzel, Barbara
    Kahraman, Guenal
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (05): : 643 - 647
  • [48] The incidence of cystoid macular oedema in cases with in-the-bag intraocular lens and ciliary sulcus intraocular lens
    Gaber, E
    ElBaha, S
    Hussein, F
    ElSayed, M
    SOE '97 - XI CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, VOLS 1 AND 2, 1997, : 773 - 778
  • [49] Coaxially sighted intraocular lens light reflex for centration of the multifocal single piece intraocular lens
    Melki, Samir A.
    Harissi-Dagher, Mona
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2011, 46 (04): : 319 - 321
  • [50] INTRAOCULAR-LENS POWER CALCULATIONS FOR MULTIFOCAL INTRAOCULAR LENSES - REPLY
    HOLLADAY, JT
    HOFFER, KJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (02) : 270 - 270