Additional multifocal sulcus-based intraocular lens: Alternative to multifocal intraocular lens in the capsular bag

被引:18
|
作者
Schrecker, Jens [1 ]
Kroeber, Sandra [1 ]
Eppig, Timo [2 ]
Langenbucher, Achim [2 ]
机构
[1] Klinikum Rudolf Virchow, Dept Ophthalmol, D-08371 Glauchau, Germany
[2] Univ Saarland, Homburg, Germany
来源
关键词
ADD-ON IOL; PSEUDOPHAKIC EYES; CONTRAST SENSITIVITY; PUPIL SIZE; IMPLANTATION; ASTIGMATISM; ACUITY;
D O I
10.1016/j.jcrs.2012.10.047
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual outcomes of additional multifocal intraocular lenses (IOLs) for sulcus fixation with those of standard multifocal IOLs in the capsular bag. SETTING: Department of Ophthalmology, Rudolf-Virchow-Klinikum Glauchau, Glauchau, Germany. DESIGN: Prospective controlled clinical trial. METHODS: Eyes had phacoemulsification and implantation of a monofocal IOL in the capsular bag and an additional aberration-free diffractive IOL in the ciliary sulcus (multifocal add-on IOL group). Measurements of uncorrected and distance-corrected distance, intermediate, and near visual acuities; contrast sensitivity; and defocus curve were performed 3 months postoperatively. Results were compared with those in eyes with an aberration-correcting diffractive posterior chamber IOL (multifocal PC IOL group). RESULTS: The multifocal add-on IOL group comprised 34 eyes of 20 patients and the multifocal PC IOL group, 31 eyes of 17 patients. Cataract surgery, IOL implantation, and the postoperative course were uneventful in all cases. There were no statistically significant differences in uncorrected and distance-corrected distance, intermediate, or near visual acuities between the 2 groups. The median uncorrected distance visual acuity was 0.00 logMAR in both groups, and the median uncorrected near visual acuity was 0.10 logMAR in both groups. Contrast sensitivity testing yielded significantly better results in the multifocal add-on IOL group, especially at spatial frequencies over 1.5 cycles per degree. Defocus curves were similar in the 2 groups. CONCLUSION: Visual performance with a multifocal diffractive add-on IOL was equivalent to that achieved with a commonly used multifocal diffractive PC IOL.
引用
收藏
页码:548 / 555
页数:8
相关论文
共 50 条
  • [21] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [22] Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye
    Jae Yong Kim
    Yunhan Lee
    Hun Jae Won
    Hyerin Jeong
    Jin Hyoung Park
    Myoung Joon Kim
    Hungwon Tchah
    International Journal of Ophthalmology, 2020, (05) : 737 - 743
  • [23] Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye
    Kim, Jae Yong
    Lee, Yunhan
    Won, Hun Jae
    Jeong, Hyerin
    Park, Jin Hyoung
    Kim, Myoung Joon
    Tchah, Hungwon
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (05) : 737 - 743
  • [24] Managing dissatisfaction after multifocal intraocular lens implantation through lens exchange using monofocal or alternative multifocal IOLs
    Al-Shymali, Olena
    Canto, Mario
    Alio del Barrio, Jorge L.
    McAlinden, Colm
    Yebana, Pilar
    Alio, Jorge L.
    ACTA OPHTHALMOLOGICA, 2024, 102 (07) : e1040 - e1049
  • [25] Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens
    Lee, Shinwook
    Choi, Myoung
    Xu, Zaiwei
    Zhao, Zeyu
    Alexander, Elsinore
    Liu, Yueai
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1031 - 1038
  • [26] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [27] Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (03) : 192 - 196
  • [28] Capsular bag distension after optic capture of a sulcus-fixated intraocular lens
    Basti, S
    Nayak, H
    Mathur, U
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02): : 293 - 295
  • [29] Rotationally asymmetric multifocal intraocular lens Reply
    van der Linden, Jan Willem
    van Velthoven, Mirjam
    van der Meulen, Ivanka
    Nieuwendaal, Carla
    Mourits, Maarten
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1117 - 1117
  • [30] Fractal-structured multifocal intraocular lens
    Remon, Laura
    Garcia-Delpech, Salvador
    Udaondo, Patricia
    Ferrando, Vicente
    Monsoriu, Juan A.
    Furlan, Walter D.
    PLOS ONE, 2018, 13 (07):