An 8-Channel Transceiver Coil for Carotid Artery Imaging at 7T Using an Optimized Shield Design

被引:0
|
作者
Yazdanbakhsh, Pedram [1 ,2 ]
Couch, Marcus [1 ,2 ,3 ]
Gilbert, Kyle M. [4 ]
Der Hovagimian, Johnny [1 ,5 ,6 ]
Rudko, David A. [1 ,2 ,5 ]
Hoge, Richard D. [1 ,2 ,5 ]
机构
[1] McGill Univ, Montreal Neurol Inst & Hosp, McConnell Brain Imaging Ctr, Montreal, PQ H3A 0G4, Canada
[2] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ H3A 0G4, Canada
[3] Siemens Healthcare Ltd, Ottawa, ON, Canada
[4] Western Univ, Ctr Funct & Metab Mapping, London, ON, Canada
[5] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[6] AEM Antennas Inc, Montreal, PQ, Canada
基金
加拿大健康研究院;
关键词
Coils; Radio frequency; Switches; Capacitors; Carotid arteries; Preamplifiers; Phase shifters; 7; tesla; carotid imaging; high-field MRI; parallel transmission; phased array RF coil; ARRAYS;
D O I
10.1109/TBME.2024.3379980
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: To design and fabricate a transmit/receive (T/R) radiofrequency (RF) coil array for MRI of the carotid arteries at 7T with optimal shielding to improve transmit performance in parallel transmit (pTx) mode. Methods: The carotid coil included 8 total RF elements, with left and right subarrays, each consisting of 4 overlapping loops with RF shields. Electromagnetic (EM) simulations were performed to optimize and improve the transmit performance of the array by determining the optimal distance between the RF shield and each subarray. EM simulations were further used to calculate local specific absorption rate (SAR) matrices. Based on the SAR matrices, virtual observation points (VOPs) were applied to ensure safety during parallel transmission. The efficacy of the coil design was evaluated by measuring coil performance metrics when imaging a phantom and by acquiring in-vivo images. Results: The optimal distance between the RF shield and each subarray was determined to be 45 mm. This resulted in a maximum B-1(+) efficiency of 1.23 mu T/$\surd W$ in the carotid arteries and a peak, 10-g-average SAR per Watt of 0.86 kg(-1) when transmitting in the nominal CP+ mode. Optimizing the RF shield resulted in up to 37% improvement in B-1(+) efficiency and 14% improvement in SAR efficiency compared to an unshielded design. Conclusion and significance: Optimizing the distance between the RF shield and coil array provided significant improvement in the transmit characteristics of the bilateral carotid coil. The bilateral coil topology provides a compelling platform for imaging the carotid arteries with high field MRI.
引用
收藏
页码:2537 / 2544
页数:8
相关论文
共 50 条
  • [1] Design and construction of an 8-channel transceiver coil array for rat imaging at 9.4 T
    Du, Feng
    Li, Nan
    Yang, Xing
    Zhang, Baogui
    Zhang, Xiaoliang
    Li, Ye
    JOURNAL OF MAGNETIC RESONANCE, 2023, 351
  • [2] Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T
    Jaeschke, Sven H. F.
    Robson, Matthew D.
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 633 - 640
  • [3] An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T
    Hu, Xiaoqing
    Zhang, Lei
    Zhang, Xiaoliang
    Zhu, Huabin
    Chen, Xiao
    Zhang, Yongqin
    Chung, Yiu-Cho
    Liu, Xin
    Zheng, Hairong
    Li, Ye
    MEDICAL PHYSICS, 2016, 43 (04) : 1897 - 1906
  • [4] An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T
    Rietsch, Stefan H. G.
    Pfaffenrot, Viktor
    Bitz, Andreas K.
    Orzada, Stephan
    Brunheim, Sascha
    Lazik-Palm, Andrea
    Theysohn, Jens M.
    Ladd, Mark E.
    Quick, Harald H.
    Kraff, Oliver
    MEDICAL PHYSICS, 2017, 44 (12) : 6195 - 6208
  • [5] An 8-Channel RF Coil based on Microstrip Yagi-antenna for 7T Magnetic Resonance Imaging
    He, Ke
    Yu, Mengxia
    Zhao, E.
    Li, Guiping
    Wang, Maoyan
    Ma, Jing
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 635 - 636
  • [6] In vivo imaging of electrical properties of an animal tumor model with an 8-channel transceiver array at 7T using electrical properties tomography
    Liu, Jiaen
    Shao, Qi
    Wang, Yicun
    Adriany, Gregor
    Bischof, John
    Van de Moortele, Pierre-Francois
    He, Bin
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2157 - 2169
  • [7] A human cerebral and cerebellar 8-channel transceive RF dipole coil array at 7T
    Clement, Jeremie D.
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1447 - 1458
  • [8] Imaging the Internal Auditory Canal with an 8? 2 Transceiver Array Head Coil at 7T
    Nada, A.
    Cousins, J. P.
    Rivera, A.
    Carr, S. B.
    Jones, J.
    Minor, C.
    Hetherington, H. P.
    Kim, J. H.
    Pan, J. W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (04) : 852 - 858
  • [9] Global Maxwell Tomography using an 8-channel radiofrequency coil: simulation results for a tissue-mimicking phantom at 7T
    Giannakopoulos, Ilias I.
    Serralles, Jose E. C.
    Zhang, Bei
    Daniel, Luca
    White, Jacob K.
    Lattanzi, Riccardo
    2019 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND USNC-URSI RADIO SCIENCE MEETING, 2019, : 823 - 824
  • [10] 7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array
    Rietsch, Stefan H. G.
    Orzada, Stephan
    Maderwald, Stefan
    Brunheim, Sascha
    Philips, Bart W. J.
    Scheenen, Tom W. J.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2018, 45 (07) : 2978 - 2990