Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T

被引:5
|
作者
Jaeschke, Sven H. F. [1 ]
Robson, Matthew D. [1 ]
Hess, Aaron T. [1 ]
机构
[1] Univ Oxford, Ctr Clin Magnet Resonance Res, John Radcliffe Hosp, Oxford, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
parallel transmit; cardiac gating; motion sensor; cardiac MRI; reflected power; RF scattering; RF COIL; RESONANCE;
D O I
10.1002/mrm.27038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. MethodsMeasurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequence and during a standard cine acquisition, respectively. Postprocessing used an independent component analysis and gating feature identification. The effect of the phase of the excitation radiofrequency (RF) field ( B1+ shim) on the cardiac signal was simulated for multiple B1+ shim configurations, and cine images were reconstructed from both the scattering coefficients and electrocardiogram (ECG). ResultsThe cardiac motion signal was successfully identified in all subjects with a mean signal-to-noise ratio of 33.1 and 5.7 using the scattering matrix and scattering coefficient measurements, respectively. The dominant gating feature in the cardiac signal was a peak aligned with end-systole that occurred on average at 311 and 391 ms after the ECG trigger, with a mean standard deviation of 13.4 and 18.1 ms relative to ECG when using the scattering matrix and scattering coefficients measurements, respectively. The scattering coefficients showed a dependence on B1+ shim with some shim configurations not showing any cardiac signal. Cine images were successfully reconstructed using the scattering coefficients with minimal differences compared to those using ECG. ConclusionWe have shown that the scattering of a pTx RF coil can be used to estimate a cardiac signal, and that scattering matrix and coefficients can be used to cardiac gate MRI acquisitions with the scattering matrix providing a superior cardiac signal. Magn Reson Med 80:633-640, 2018. (c) 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [1] An 8-Channel Transceiver Coil for Carotid Artery Imaging at 7T Using an Optimized Shield Design
    Yazdanbakhsh, Pedram
    Couch, Marcus
    Gilbert, Kyle M.
    Der Hovagimian, Johnny
    Rudko, David A.
    Hoge, Richard D.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (08) : 2537 - 2544
  • [2] A human cerebral and cerebellar 8-channel transceive RF dipole coil array at 7T
    Clement, Jeremie D.
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1447 - 1458
  • [3] 7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array
    Rietsch, Stefan H. G.
    Orzada, Stephan
    Maderwald, Stefan
    Brunheim, Sascha
    Philips, Bart W. J.
    Scheenen, Tom W. J.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2018, 45 (07) : 2978 - 2990
  • [4] An open 8-channel parallel transmission coil for static and dynamic 7T MRI of the knee and ankle joints at multiple postures
    Jin, Jin
    Weber, Ewald
    Destruel, Aurelien
    O'Brien, Kieran
    Henin, Bassem
    Engstrom, Craig
    Crozier, Stuart
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1804 - 1816
  • [5] A combined 32-channel receive-loops/8-channel transmit-dipoles coil array for whole-brain MR imaging at 7T
    Clement, Jeremie
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1229 - 1241
  • [6] Global Maxwell Tomography using an 8-channel radiofrequency coil: simulation results for a tissue-mimicking phantom at 7T
    Giannakopoulos, Ilias I.
    Serralles, Jose E. C.
    Zhang, Bei
    Daniel, Luca
    White, Jacob K.
    Lattanzi, Riccardo
    2019 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND USNC-URSI RADIO SCIENCE MEETING, 2019, : 823 - 824
  • [7] An 8-Channel RF Coil based on Microstrip Yagi-antenna for 7T Magnetic Resonance Imaging
    He, Ke
    Yu, Mengxia
    Zhao, E.
    Li, Guiping
    Wang, Maoyan
    Ma, Jing
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 635 - 636
  • [8] Design and Application of a Four-Channel Transmit/Receive Surface Coil for Functional Cardiac Imaging at 7T
    Dieringer, Matthias A.
    Renz, Wolfgang
    Lindel, Tomasz
    Seifert, Frank
    Frauenrath, Tobias
    von Knobelsdorff-Brenkenhoff, Florian
    Waiczies, Helmar
    Hoffmann, Werner
    Rieger, Jan
    Pfeiffer, Harald
    Ittermann, Bernd
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) : 736 - 741
  • [9] Design of a Parallel Transmit Head Coil at 7T With Magnetic Wall Distributed Filters
    Connell, Ian R. O.
    Gilbert, Kyle M.
    Abou-Khousa, Mohamed A.
    Menon, Ravi S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (04) : 836 - 845
  • [10] An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T
    Rietsch, Stefan H. G.
    Pfaffenrot, Viktor
    Bitz, Andreas K.
    Orzada, Stephan
    Brunheim, Sascha
    Lazik-Palm, Andrea
    Theysohn, Jens M.
    Ladd, Mark E.
    Quick, Harald H.
    Kraff, Oliver
    MEDICAL PHYSICS, 2017, 44 (12) : 6195 - 6208