Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T

被引:5
|
作者
Jaeschke, Sven H. F. [1 ]
Robson, Matthew D. [1 ]
Hess, Aaron T. [1 ]
机构
[1] Univ Oxford, Ctr Clin Magnet Resonance Res, John Radcliffe Hosp, Oxford, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
parallel transmit; cardiac gating; motion sensor; cardiac MRI; reflected power; RF scattering; RF COIL; RESONANCE;
D O I
10.1002/mrm.27038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. MethodsMeasurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequence and during a standard cine acquisition, respectively. Postprocessing used an independent component analysis and gating feature identification. The effect of the phase of the excitation radiofrequency (RF) field ( B1+ shim) on the cardiac signal was simulated for multiple B1+ shim configurations, and cine images were reconstructed from both the scattering coefficients and electrocardiogram (ECG). ResultsThe cardiac motion signal was successfully identified in all subjects with a mean signal-to-noise ratio of 33.1 and 5.7 using the scattering matrix and scattering coefficient measurements, respectively. The dominant gating feature in the cardiac signal was a peak aligned with end-systole that occurred on average at 311 and 391 ms after the ECG trigger, with a mean standard deviation of 13.4 and 18.1 ms relative to ECG when using the scattering matrix and scattering coefficients measurements, respectively. The scattering coefficients showed a dependence on B1+ shim with some shim configurations not showing any cardiac signal. Cine images were successfully reconstructed using the scattering coefficients with minimal differences compared to those using ECG. ConclusionWe have shown that the scattering of a pTx RF coil can be used to estimate a cardiac signal, and that scattering matrix and coefficients can be used to cardiac gate MRI acquisitions with the scattering matrix providing a superior cardiac signal. Magn Reson Med 80:633-640, 2018. (c) 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [31] Sodium imaging of the heart at 7T: design, evaluation and application of a four-channel transmit/receive surface coil array
    A Graessl
    A Ruehle
    W Renz
    L Winter
    H Pfeiffer
    J Ruff
    J Rieger
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [32] Enhancement of transmit and receive efficiencies with hybridized meta -atom in 7T head coil array
    Dubois, Marc
    Leroi, Lisa
    Vignaud, Alexandre
    Enoch, Stefan
    Abdeddaim, Redha
    PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2019, : 942 - 942
  • [33] Specific Absorption Rate Intersubject Variability in 7T Parallel Transmit MRI of the Head
    de Greef, Martijn
    Ipek, Ozlem
    Raaijmakers, Alexander J. E.
    Crezee, Johannes
    van den Berg, Cornelis A. T.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1476 - 1485
  • [34] Parallel transmit 7T MRI for adult epilepsy pre-surgical evaluation
    Klodowski, Krzysztof
    Zhang, Minghao
    Jen, Jian P.
    Scoffings, Daniel J.
    Morris, Robert
    Lupson, Victoria
    Mauconduit, Franck
    Massire, Aurelien
    Gras, Vincent
    Boulant, Nicolas
    Rodgers, Christopher T.
    Cope, Thomas E.
    EPILEPSIA, 2025,
  • [35] Simultaneous Multislice Imaging in Dynamic Cardiac MRI at 7T Using Parallel Transmission
    Schmitter, Sebastian
    Moeller, Steen
    Wu, Xiaoping
    Auerbach, Edward J.
    Metzger, Gregory J.
    Van de Moortele, Pierre-Francois
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1010 - 1020
  • [36] Head-and-neck multichannel B1+ mapping and RF shimming of the carotid arteries using a 7T parallel-transmit head coil
    de Buck, Matthijs H. S.
    Kent, James L.
    Jezzard, Peter
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (01) : 190 - 204
  • [37] Evaluation of a novel 8-channel RX coil for speech production MRI at 0.55 T
    Munoz, Felix
    Lim, Yongwan
    Cui, Sophia X.
    Stark, Helmut
    Nayak, Krishna S.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (03) : 419 - 426
  • [38] Evaluation of a novel 8-channel RX coil for speech production MRI at 0.55 T
    Felix Muñoz
    Yongwan Lim
    Sophia X. Cui
    Helmut Stark
    Krishna S. Nayak
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 419 - 426
  • [39] Design and construction of an 8-channel transceiver coil array for rat imaging at 9.4 T
    Du, Feng
    Li, Nan
    Yang, Xing
    Zhang, Baogui
    Zhang, Xiaoliang
    Li, Ye
    JOURNAL OF MAGNETIC RESONANCE, 2023, 351
  • [40] Comparison of 7T 16-channel dual-row transmit arrays
    Kozlov, M.
    Bode, J.
    Bazin, P. -L.
    Weiskopf, N.
    Moeller, H. E.
    Shajan, G.
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1264 - 1267