1-Octanol-assisted ultra-small volume droplet microfluidics with nanoelectrospray ionization mass spectrometry

被引:1
|
作者
Zhao, Yaoyao [1 ,2 ,7 ]
Park, Insu [3 ]
Rubakhin, Stanislav S. [1 ,2 ]
Bashir, Rashid [4 ,5 ,6 ]
Vlasov, Yurii [4 ,5 ,6 ]
Sweedler, Jonathan V. [1 ,2 ,6 ]
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[3] Univ Illinois, Holonyak Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[4] Univ Illinois, Beckman Inst Adv Sci & Technol, Holonyak Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[5] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[6] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[7] Beijing Univ Technol, Dept Chem, Beijing 100124, Peoples R China
基金
美国国家卫生研究院;
关键词
Cerebral spinal fluid; Neurotransmitters; Low volume sampling; Droplet microfluidics; Mass spectrometry; CEREBROSPINAL-FLUID; PICOLITER DROPLETS; NANOLITER-SCALE; SEGMENTED FLOW; PLATFORM; ACETYLCHOLINE; CAPILLARY; ARRAY;
D O I
10.1016/j.aca.2024.342998
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Droplet microfluidics with push-pull and microdialysis sampling from brain slices, cultured cells and engineered tissues produce low volume mass limited samples containing analytes sampled from the extracellular space. This sampling approach coupled to mass spectrometry (MS) detection allows evaluation of time- dependent chemical changes. Our goal is an approach for continuous sampling and segregation of extracellular samples into picoliter droplets followed by the characterization of the droplets using nanoelectrospray ionization (nESI) MS. The main focus here is the optimization of the carrier oil for the microfluidic device that neither affects the stability of picoliter droplets nor compatibility with MS detection of a range of analytes. Results: We developed and characterized a 1-octanol-assisted ultra-small volume droplet microfluidic nESI MS system for the analysis of neurotransmitters in distinct samples including cerebrospinal fluid (CSF). The use of a 1-octanol oil phase was effective for generation of aqueous droplets as small as 65 pL and enabled detection of acetylcholine (ACh) and gamma-aminobutyric acid (GABA) in water and artificial CSF. Continuous MS analysis of droplets for extended periods up to 220 min validated the long-term stability of droplet generation and analyte detection by nESI-MS. As an example, ACh response demonstrated a linear working range (R2 2 = 0.99) between 0.4 mu M and 25 mu M with a limit of detection of 370 nM (24 amol), enabling its quantitation in rodent CSF. Significance: The established droplet microfluidics - nESI MS approach allows the analysis of microenvironments at high spatiotemporal resolution. The approach may allow microsampling and monitoring of spatiotemporal dynamics of neurochemicals and drugs in the brain and spinal cord of live animals.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Graphite Sheet-Assisted Laser Desorption Ionization-Mass Spectrometry for Small Organic Compound Analysis
    Liu, Zhuofei
    Arima, Keishiro
    Nishiki, Naomi
    Kuwabara, Ryou
    Ishitani, Shinji
    Matsui, Toshiro
    Tanaka, Mitsuru
    ACS OMEGA, 2024, 9 (25): : 27739 - 27747
  • [42] Nanostructured Layer of Silver for Detection of Small Biomolecules in Surface-Assisted Laser Desorption Ionization Mass Spectrometry
    Arendowski, Adrian
    Sagandykova, Gulyaim
    Mametov, Radik
    Rafinska, Katarzyna
    Pryshchepa, Oleksandra
    Pomastowski, Pawel
    MATERIALS, 2022, 15 (12)
  • [43] Recent Advances in Surface-Assisted Laser Desorption/Ionization Mass Spectrometry and Its Imaging for Small Molecules
    Huan Huang
    Dan Ouyang
    Zi-An Lin
    Journal of Analysis and Testing, 2022, 6 : 217 - 234
  • [44] Platinum vapor deposition surface-assisted laser desorption/ionization for imaging mass spectrometry of small molecules
    Kawasaki, Hideya
    Ozawa, Tomoyuki
    Hisatomi, Hirotaka
    Arakawa, Ryuichi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (16) : 1849 - 1858
  • [45] Derivatization with 1-Pyrenyldiazomethane Enhances Ionization of Glycopeptides but Not Peptides in Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    Amano, Junko
    Nishikaze, Takashi
    Tougasaki, Fumio
    Jinmei, Hiroshi
    Sugimoto, Ichiro
    Sugawara, Shu-ichi
    Fujita, Masaya
    Osumi, Kenji
    Mizuno, Mamoru
    ANALYTICAL CHEMISTRY, 2010, 82 (20) : 8738 - 8743
  • [46] SMALL-VOLUME AND LOW FLOW-RATE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF AQUEOUS SAMPLES
    GALE, DC
    SMITH, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) : 1017 - 1021
  • [47] Droplet spray ionization mass spectrometry for real-time monitoring of activation of peroxymonosulfate by 1,4-benzoquinone
    Zhang, Hong
    Yu, Kai
    He, Jing
    Li, Na
    You, Hong
    Jiang, Jie
    MICROCHEMICAL JOURNAL, 2018, 139 : 437 - 442
  • [48] Maltose-functional metal–organic framework assisted laser desorption/ionization mass spectrometry for small biomolecule determination 
    Wen Ma
    Bingxin Yang
    Jun Li
    Mingxia Liu
    Xianjiang Li
    Huwei Liu
    Microchimica Acta, 2022, 189
  • [49] Analysis of small organics on planar silica surfaces using surface-assisted laser desorption/ionization mass spectrometry
    Chen, YC
    Wu, JY
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (20) : 1899 - 1903
  • [50] Assessing the properties of internal standards for quantitative matrix-assisted laser desorption/ionization mass spectrometry of small molecules
    Sleno, Lekha
    Volmer, Dietrich A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (10) : 1517 - 1524