1-Octanol-assisted ultra-small volume droplet microfluidics with nanoelectrospray ionization mass spectrometry

被引:1
|
作者
Zhao, Yaoyao [1 ,2 ,7 ]
Park, Insu [3 ]
Rubakhin, Stanislav S. [1 ,2 ]
Bashir, Rashid [4 ,5 ,6 ]
Vlasov, Yurii [4 ,5 ,6 ]
Sweedler, Jonathan V. [1 ,2 ,6 ]
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[3] Univ Illinois, Holonyak Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[4] Univ Illinois, Beckman Inst Adv Sci & Technol, Holonyak Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[5] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[6] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[7] Beijing Univ Technol, Dept Chem, Beijing 100124, Peoples R China
基金
美国国家卫生研究院;
关键词
Cerebral spinal fluid; Neurotransmitters; Low volume sampling; Droplet microfluidics; Mass spectrometry; CEREBROSPINAL-FLUID; PICOLITER DROPLETS; NANOLITER-SCALE; SEGMENTED FLOW; PLATFORM; ACETYLCHOLINE; CAPILLARY; ARRAY;
D O I
10.1016/j.aca.2024.342998
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Droplet microfluidics with push-pull and microdialysis sampling from brain slices, cultured cells and engineered tissues produce low volume mass limited samples containing analytes sampled from the extracellular space. This sampling approach coupled to mass spectrometry (MS) detection allows evaluation of time- dependent chemical changes. Our goal is an approach for continuous sampling and segregation of extracellular samples into picoliter droplets followed by the characterization of the droplets using nanoelectrospray ionization (nESI) MS. The main focus here is the optimization of the carrier oil for the microfluidic device that neither affects the stability of picoliter droplets nor compatibility with MS detection of a range of analytes. Results: We developed and characterized a 1-octanol-assisted ultra-small volume droplet microfluidic nESI MS system for the analysis of neurotransmitters in distinct samples including cerebrospinal fluid (CSF). The use of a 1-octanol oil phase was effective for generation of aqueous droplets as small as 65 pL and enabled detection of acetylcholine (ACh) and gamma-aminobutyric acid (GABA) in water and artificial CSF. Continuous MS analysis of droplets for extended periods up to 220 min validated the long-term stability of droplet generation and analyte detection by nESI-MS. As an example, ACh response demonstrated a linear working range (R2 2 = 0.99) between 0.4 mu M and 25 mu M with a limit of detection of 370 nM (24 amol), enabling its quantitation in rodent CSF. Significance: The established droplet microfluidics - nESI MS approach allows the analysis of microenvironments at high spatiotemporal resolution. The approach may allow microsampling and monitoring of spatiotemporal dynamics of neurochemicals and drugs in the brain and spinal cord of live animals.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Identification of recombinant human parathyroid hormone (1-34) by nanoelectrospray ionization-quadrupole-time of filght tandem mass spectrometry
    Chen Jing
    Sun Hongying
    Chen Shuqing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 603 - 607
  • [32] Recommendations for quantitative analysis of small molecules by matrix-assisted laser desorption ionization mass spectrometry
    Wang, Poguang
    Giese, Roger W.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1486 : 35 - 41
  • [33] Small-molecule analysis with silicon-nanoparticle-assisted laser desorption/ionization mass spectrometry
    Wen, Xiujuan
    Dagan, Shai
    Wysocki, Vicki H.
    ANALYTICAL CHEMISTRY, 2007, 79 (02) : 434 - 444
  • [34] Interfacing Droplet Microfluidics with Matrix-Assisted Laser Desorption/lonization Mass Spectrometry: Label-Free Content Analysis of Single Droplets
    Kuester, Simon K.
    Fagerer, Stephan R.
    Verboket, Pascal E.
    Eyer, Klaus
    Jefimovs, Konstantins
    Zenobi, Renato
    Dittrich, Petra S.
    ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1285 - 1289
  • [35] Identification of methylation and acetylation sites on mouse histone H3 using matrix-assisted laser desorption/ionization time-of-flight and nanoelectrospray ionization tandem mass spectrometry
    Cocklin, RR
    Wang, M
    JOURNAL OF PROTEIN CHEMISTRY, 2003, 22 (04): : 327 - 334
  • [36] Identification of Methylation and Acetylation Sites on Mouse Histone H3 Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight and Nanoelectrospray Ionization Tandem Mass Spectrometry
    Ross R. Cocklin
    Mu Wang
    Journal of Protein Chemistry, 2003, 22 : 327 - 334
  • [37] Recent Advances in Surface-Assisted Laser Desorption/Ionization Mass Spectrometry and Its Imaging for Small Molecules
    Huan Huang
    Dan Ouyang
    Zi-An Lin
    JournalofAnalysisandTesting, 2022, 6 (03) : 217 - 234
  • [38] Visible surface-assisted laser desorption/ionization mass spectrometry of small macromolecules deposited on the graphite plate
    Kim, J
    Paek, K
    Kang, W
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2002, 23 (02) : 315 - 319
  • [39] Recent Advances in Surface-Assisted Laser Desorption/Ionization Mass Spectrometry and Its Imaging for Small Molecules
    Huang, Huan
    Ouyang, Dan
    Lin, Zi-An
    JOURNAL OF ANALYSIS AND TESTING, 2022, 6 (03) : 217 - 234
  • [40] Nanomaterials as Assisted Matrix of Laser Desorption/Ionization Time-of-Flight Mass Spectrometry for the Analysis of Small Molecules
    Lu, Minghua
    Yang, Xueqing
    Yang, Yixin
    Qin, Peige
    Wu, Xiuru
    Cai, Zongwei
    NANOMATERIALS, 2017, 7 (04):