PET digitization chain for Monte Carlo simulation in GATE

被引:2
|
作者
Salvadori, Julien [1 ]
Merlet, Antoine [2 ]
Presles, Benoit [2 ]
Cabello, Jorge [3 ]
Su, Kuan-Hao [4 ]
Cochet, Alexandre [2 ,5 ]
Etxebeste, Ane [6 ,7 ,8 ]
Vrigneaud, Jean-Marc [2 ,5 ]
Sarrut, David [6 ,7 ,8 ]
机构
[1] Inst Cancerol Strasbourg Europe ICANS, Grp Cooperat Sanit, Nucl Med, Strasbourg, France
[2] Univ Burgundy, Inst Chim Mol Univ Bourgogne ICMUB, UMR CNRS 6302, Dijon, France
[3] Siemens Med Solut USA Inc, Knoxville, TN USA
[4] GE Healthcare, Waukesha, WI USA
[5] Georges Francois Leclerc Canc Ctr, Dept Nucl Med, Dijon, France
[6] Univ Lyon, CREATIS, Lyon, France
[7] INSA Lyon, CNRS UMR5220, Inserm U1044, Lyon, France
[8] Univ Lyon 1, Ctr Leon Berard, Lyon, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 16期
关键词
PET; GATE; Monte-Carlo simulation; digitizer; SILICON-PHOTOMULTIPLIER; VALIDATION; DETECTOR; RATES; MODEL;
D O I
10.1088/1361-6560/ad638c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. We introduce a versatile methodology for the accurate modelling of PET imaging systems via Monte Carlo simulations, using the Geant4 application for tomographic emission (GATE) platform. Accurate Monte Carlo modelling involves the incorporation of a complete analytical signal processing chain, called the digitizer in GATE, to emulate the different count rates encountered in actual positron emission tomography (PET) systems. Approach. The proposed approach consists of two steps: (1) modelling the digitizer to replicate the detection chain of real systems, covering all available parameters, whether publicly accessible or supplied by manufacturers; (2) estimating the remaining parameters, i.e. background noise level, detection efficiency, and pile-up, using optimisation techniques based on experimental single and prompt event rates. We show that this two-step optimisation reproduces the other experimental count rates (true, scatter, and random), without the need for additional adjustments. This method has been applied and validated with experimental data derived from the NEMA count losses test for three state-of-the-art SiPM-based time-of-flight (TOF)-PET systems: Philips Vereos, Siemens Biograph Vision 600 and GE Discovery MI 4-ring. Main results. The results show good agreement between experiments and simulations for the three PET systems, with absolute relative discrepancies below 3%, 6%, 6%, 7% and 12% for prompt, random, true, scatter and noise equivalent count rates, respectively, within the 0-10 kBq<middle dot>ml-1 activity concentration range typically observed in whole-body 18F scans. Significance. Overall, the proposed digitizer optimisation method was shown to be effective in reproducing count rates and NECR for three of the latest generation SiPM-based TOF-PET imaging systems. The proposed methodology could be applied to other PET scanners.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Monte Carlo simulations studies in small animal PET using GATE
    Branco, S.
    Jan, S.
    Almeida, P.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3994 - +
  • [22] Monte Carlo Simulation of InAlAs/InGaAs HEMTs with Buried Gate
    Endoh, Akira
    Watanabe, Issei
    Kasamatsu, Akifumi
    Mimura, Takashi
    2013 INTERNATIONAL CONFERENCE ON INDIUM PHOSPHIDE AND RELATED MATERIALS (IPRM), 2013,
  • [23] Monte Carlo simulation of the Inveon microPET system using GATE
    Dartial, Nadege
    Carlier, Thomas
    Fusellier, Marion
    Desfontis, Jean-Claude
    Visvikis, Dimitris
    Bardies, Manuel
    Hindorf, Cecilia
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [24] Monte Carlo simulation of a scintillation crystal read by a SiPM with GATE
    Mehadji, Brahim
    Dupont, Mathieu
    Fougeron, Denis
    Morel, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [25] Monte Carlo simulation of two Siemens Biograph PET/CT system using GATE: Image quality performance
    Saaidi, Rahal
    Zeghari, Abdelkrim
    El Moursli, Rajaa Cherkaoui
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [26] Monte Carlo simulation of Ray-Scan 64 PET system and performance evaluation using GATE toolkit
    Li, Suying
    Zhang, Qiushi
    Vuletic, Ivan
    Xie, Zhaoheng
    Yang, Kun
    Ren, Qiushi
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [27] Validation of GATE Monte Carlo simulation of the performance characteristics of a GE eXplore VISTA small animal PET system
    Yang, C. C.
    Seidel, J.
    Wang, Y.
    Lee, J. S.
    Pomper, M. G.
    Tsui, B. M. W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3187 - +
  • [28] Ensemble preconditioning for Markov chain Monte Carlo simulation
    Benedict Leimkuhler
    Charles Matthews
    Jonathan Weare
    Statistics and Computing, 2018, 28 : 277 - 290
  • [29] THE MONTE-CARLO SIMULATION OF PEARL CHAIN FORMATION
    MARSZALEK, P
    GODZIK, A
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1987, 26 (04) : 313 - 317
  • [30] Ensemble preconditioning for Markov chain Monte Carlo simulation
    Leimkuhler, Benedict
    Matthews, Charles
    Weare, Jonathan
    STATISTICS AND COMPUTING, 2018, 28 (02) : 277 - 290