Design and Test of an Intraoral Electrode Grid for Tongue High-Density Electromyography

被引:0
|
作者
Botter, Alberto [1 ,2 ]
Vieira, Taian [1 ,2 ]
Busso, Chiara [3 ]
Vitali, Federica [1 ,2 ]
Gazzoni, Marco [1 ,2 ]
Cerone, Giacinto L. [1 ,2 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, Lab Engn Neuromuscular Syst LISiN, I-10129 Turin, Italy
[2] Politecn Torino, Polito BIOMed Lab, I-10129 Turin, Italy
[3] Univ Turin, Dept Surg Sci, Div Phys Med & Rehabil, I-10124 Turin, Italy
关键词
Electrode technology; electromyography; motor unit; decomposition; speech; tongue muscles; BIOMECHANICAL MODEL; SURFACE; SYSTEM; ARRAY;
D O I
10.1109/TNSRE.2024.3434360
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tongue motor function is crucial in a wide range of basic activities and its impairment affects quality of life. The electrophysiological assessment of the tongue relies primarily on needle electromyography, which is limited by its invasiveness and inability to capture the concurrent activity of the different tongue muscles. This work aimed at developing an intraoral grid for high-density surface electromyography (HDsEMG) to non-invasively map the electrical excitation of tongue muscles. We developed a grid of 4 x 8 electrodes deposited over an adhesive 8- $\mu $ m thick polyurethane membrane. The testing protocol was conducted on 7 healthy participants and included functional tasks (vowels articulation and tongue movements) aimed at activating different regions of the tongue. The electrical stability of contact was assessed by measuring electrode-tongue impedances before and after the tasks. The spatial amplitude distribution of global EMG and single motor unit action potentials (MUAPs) was characterized. Electrode-tongue impedance magnitude showed no significant changes in the pre-post comparison (58 +/- 46k Omega vs. 67 +/- 58k Omega at 50Hz). Contact stability was confirmed by the quality of the signals that allowed to quantify spatiotemporal characteristics of muscle activation during the different tasks. The analysis of the spatial distribution of individual MUAPs amplitude showed that they were confined to relatively small areas on the tongue surface (range: 0.5cm(2) -3.9cm(2)). A variety of different spatiotemporal MUAP patterns, likely due to the presence of different muscle compartments with different fiber orientations, were observed. Our results demonstrate that the developed electrode grid enables HDsEMG acquisition from the tongue during functional tasks, thus opening new possibilities in tongue muscle assessment both at global and single motor unit level.
引用
收藏
页码:2805 / 2814
页数:10
相关论文
共 50 条
  • [21] High-density package design
    Sandhu, Javed
    Varga, Ed
    Advanced Packaging, 2005, 14 (05): : 24 - 25
  • [22] A high-density electrode array for a cochlear prosthesis
    Bhatti, PT
    Arcand, BY
    Wang, J
    Butala, NV
    Friedrich, CR
    Wise, KD
    BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1750 - 1753
  • [23] Neuroethical considerations of high-density electrode arrays
    Cabrera, Laura
    Sadle, Charles
    Purcell, Erin
    NATURE BIOMEDICAL ENGINEERING, 2019, 3 (08) : 586 - 589
  • [24] Neuroethical considerations of high-density electrode arrays
    Laura Cabrera
    Charles Sadle
    Erin Purcell
    Nature Biomedical Engineering, 2019, 3 : 586 - 589
  • [25] Independent component analysis of high-density electromyography in muscle force estimation
    Staudenmann, Didier
    Daffertshofer, Andreas
    Kingma, Idsart
    Stegeman, Dick F.
    van Dieen, Jaap H.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (04) : 751 - 754
  • [26] Proportional estimation of finger movements from high-density surface electromyography
    Nicolò Celadon
    Strahinja Došen
    Iris Binder
    Paolo Ariano
    Dario Farina
    Journal of NeuroEngineering and Rehabilitation, 13
  • [27] Motor unit number estimation using high-density surface electromyography
    van Dijk, Johannes P.
    Blok, Joleen H.
    Lapatki, Bernd G.
    van Schaik, Ivo N.
    Zwarts, Machiel J.
    Stegeman, Dick F.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (01) : 33 - 42
  • [28] Proportional estimation of finger movements from high-density surface electromyography
    Celadon, Nicolo
    Dosen, Strahinja
    Binder, Iris
    Ariano, Paolo
    Farina, Dario
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2016, 13
  • [29] A Pilot Study on Quantifying Signal Quality in High-Density Surface Electromyography
    Farago, Emma
    Chan, Adrian D. C.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [30] High-density surface electromyography: A visualization method of laryngeal muscle activity
    Bracken, David J.
    Ornelas, Gladys
    Coleman, Todd P.
    Weissbrod, Philip A.
    LARYNGOSCOPE, 2019, 129 (10): : 2347 - 2353