Design and Test of an Intraoral Electrode Grid for Tongue High-Density Electromyography

被引:0
|
作者
Botter, Alberto [1 ,2 ]
Vieira, Taian [1 ,2 ]
Busso, Chiara [3 ]
Vitali, Federica [1 ,2 ]
Gazzoni, Marco [1 ,2 ]
Cerone, Giacinto L. [1 ,2 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, Lab Engn Neuromuscular Syst LISiN, I-10129 Turin, Italy
[2] Politecn Torino, Polito BIOMed Lab, I-10129 Turin, Italy
[3] Univ Turin, Dept Surg Sci, Div Phys Med & Rehabil, I-10124 Turin, Italy
关键词
Electrode technology; electromyography; motor unit; decomposition; speech; tongue muscles; BIOMECHANICAL MODEL; SURFACE; SYSTEM; ARRAY;
D O I
10.1109/TNSRE.2024.3434360
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tongue motor function is crucial in a wide range of basic activities and its impairment affects quality of life. The electrophysiological assessment of the tongue relies primarily on needle electromyography, which is limited by its invasiveness and inability to capture the concurrent activity of the different tongue muscles. This work aimed at developing an intraoral grid for high-density surface electromyography (HDsEMG) to non-invasively map the electrical excitation of tongue muscles. We developed a grid of 4 x 8 electrodes deposited over an adhesive 8- $\mu $ m thick polyurethane membrane. The testing protocol was conducted on 7 healthy participants and included functional tasks (vowels articulation and tongue movements) aimed at activating different regions of the tongue. The electrical stability of contact was assessed by measuring electrode-tongue impedances before and after the tasks. The spatial amplitude distribution of global EMG and single motor unit action potentials (MUAPs) was characterized. Electrode-tongue impedance magnitude showed no significant changes in the pre-post comparison (58 +/- 46k Omega vs. 67 +/- 58k Omega at 50Hz). Contact stability was confirmed by the quality of the signals that allowed to quantify spatiotemporal characteristics of muscle activation during the different tasks. The analysis of the spatial distribution of individual MUAPs amplitude showed that they were confined to relatively small areas on the tongue surface (range: 0.5cm(2) -3.9cm(2)). A variety of different spatiotemporal MUAP patterns, likely due to the presence of different muscle compartments with different fiber orientations, were observed. Our results demonstrate that the developed electrode grid enables HDsEMG acquisition from the tongue during functional tasks, thus opening new possibilities in tongue muscle assessment both at global and single motor unit level.
引用
收藏
页码:2805 / 2814
页数:10
相关论文
共 50 条
  • [31] Comparison of English and Chinese Speech Recognition Using High-Density Electromyography
    Zhu, Mingxing
    Yang, Zijian
    Zhuang, Jiashuo
    Wang, Xiaochen
    Lu, Lin
    Zhang, Haoshi
    Huang, Jianping
    Deng, Hanjie
    Shang, Peng
    Zhao, Guoru
    Yang, Wanzhang
    Chen, Shixiong
    Li, Guanglin
    2019 13TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2019,
  • [32] A Wearable Wireless Armband Sensor for High-Density Surface Electromyography Recording
    Tam, S.
    Bilodeau, G.
    Brown, J.
    Gagnon-Turcotte, G.
    Campeau-Lecours, A.
    Gosselin, B.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6040 - 6044
  • [33] Identifying Motor Units in Longitudinal Studies with High-Density Surface Electromyography
    Martinez-Valdes, Eduardo
    Negro, Francesco
    Laine, Christopher M.
    Falla, Deborah L.
    Mayer, Frank
    Farina, Dario
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 147 - 151
  • [34] Assessment of pelvic floor neuromuscular integrity by high-density surface electromyography
    Neshatian, L.
    Peng, Y.
    Zhang, C.
    Khavari, R.
    Boone, T.
    Quigley, M.
    Zhang, Y.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2016, 28 : 41 - 41
  • [35] Analysis of the suprahyoid muscles during tongue elevation: High-density surface electromyography as a novel tool for swallowing-related muscle assessment
    Yoshikawa, Kohei
    Nakamori, Masahiro
    Ushio, Kai
    Toko, Megumi
    Yamada, Hidetada
    Nishikawa, Yuichi
    Fukuoka, Tatsuyuki
    Maruyama, Hirofumi
    Mikami, Yukio
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (09) : 1872 - 1880
  • [36] High-density high electrode count retinal stimulating arrays
    Guven, D
    Fujii, G
    Maghribi, MN
    Okandan, M
    Krulevitch, P
    Wessendorf, K
    Weiland, JD
    Humayun, MS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U703 - U703
  • [37] Thermal design of a high-density server
    De Lorenzo, DS
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2002, 25 (04): : 635 - 640
  • [38] High-density server design methodology
    De Lorenzo, DS
    THERMAL CHALLENGES IN NEXT GENERATION ELECTRONIC SYSTEMS, 2002, : 339 - 346
  • [39] Customizable, reconfigurable, and anatomically coordinated large-area, high-density electromyography from drawn-on-skin electrode arrays
    Ershad, Faheem
    Houston, Michael
    Patel, Shubham
    Contreras, Luis
    Koirala, Bikram
    Lu, Yuntao
    Rao, Zhoulyu
    Liu, Yang
    Dias, Nicholas
    Haces-Garcia, Arturo
    Zhu, Weihang
    Zhang, Yingchun
    Yu, Cunjiang
    PNAS NEXUS, 2023, 2 (01):
  • [40] Effects of electrode on space charge in high-density polyethylene
    Chen, Shaoqing
    Zheng, Mingbo
    Wang, Xia
    Peng, Zongren
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2011, 26 (01): : 19 - 22